Nonenhanced magnetic resonance angiography (MRA) of the calf arteries at 3 Tesla: intraindividual comparison of 3D flow-dependent subtractive MRA and 2D flow-independent non-subtractive MRA

被引:11
|
作者
Knobloch, Gesine [1 ]
Lauff, Marie-Teres [1 ]
Hirsch, Sebastian [1 ]
Schwenke, Carsten [2 ]
Hamm, Bernd [1 ]
Wagner, Moritz [1 ]
机构
[1] Charite, Dept Radiol, Charite Campus Mitte, Charitepl 1, D-10117 Berlin, Germany
[2] SCO SSiS Stat Consulting, Berlin, Germany
关键词
Nonenhanced MRA; Flow-independent MRA; Flow-dependent MRA; Subtractive MRA; Non-subtractive MRA; NEPHROGENIC SYSTEMIC FIBROSIS; CONTRAST-ENHANCED MRA; SINGLE-SHOT MRA; PERIPHERAL VASCULAR-DISEASE; FAST SPIN-ECHO; LOWER-EXTREMITIES; TECHNICAL CONSIDERATIONS; OCCLUSIVE DISEASE; GUIDELINES; EXPERIENCE;
D O I
10.1007/s00330-016-4246-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To prospectively compare 3D flow-dependent subtractive MRA vs. 2D flow-independent non-subtractive MRA for assessment of the calf arteries at 3 Tesla. Forty-two patients with peripheral arterial occlusive disease underwent nonenhanced MRA of calf arteries at 3 Tesla with 3D flow-dependent subtractive MRA (fast spin echo sequence; 3D-FSE-MRA) and 2D flow-independent non-subtractive MRA (balanced steady-state-free-precession sequence; 2D-bSSFP-MRA). Moreover, all patients underwent contrast-enhanced MRA (CE-MRA) as standard-of-reference. Two readers performed a per-segment evaluation for image quality (4 = excellent to 0 = non-diagnostic) and severity of stenosis. Image quality scores of 2D-bSSFP-MRA were significantly higher compared to 3D-FSE-MRA (medians across readers: 4 vs. 3; p < 0.0001) with lower rates of non-diagnostic vessel segments on 2D-bSSFP-MRA (reader 1: < 1 % vs. 15 %; reader 2: 1 % vs. 29 %; p < 0.05). Diagnostic performance of 2D-bSSFP-MRA and 3D-FSE-MRA across readers showed sensitivities of 89 % (214/240) vs. 70 % (168/240), p = 0.0153; specificities: 91 % (840/926) vs. 63 % (585/926), p < 0.0001; and diagnostic accuracies of 90 % (1054/1166) vs. 65 % (753/1166), p < 0.0001. 2D flow-independent non-subtractive MRA (2D-bSSFP-MRA) is a robust nonenhanced MRA technique for assessment of the calf arteries at 3 Tesla with significantly higher image quality and diagnostic accuracy compared to 3D flow-dependent subtractive MRA (3D-FSE-MRA). aEuro cent 2D flow-independent non-subtractive MRA (2D-bSSFP-MRA) is a robust NE-MRA technique at 3T aEuro cent 2D-bSSFP-MRA outperforms 3D flow-dependent subtractive MRA (3D-FSE-MRA) as NE-MRA of calf arteries aEuro cent 2D-bSSFP-MRA is a promising alternative to CE-MRA for calf PAOD evaluation.
引用
收藏
页码:4585 / 4594
页数:10
相关论文
共 42 条
  • [1] Nonenhanced magnetic resonance angiography (MRA) of the calf arteries at 3 Tesla: intraindividual comparison of 3D flow-dependent subtractive MRA and 2D flow-independent non-subtractive MRA
    Gesine Knobloch
    Marie-Teres Lauff
    Sebastian Hirsch
    Carsten Schwenke
    Bernd Hamm
    Moritz Wagner
    European Radiology, 2016, 26 : 4585 - 4594
  • [2] Magnetic resonance angiography (MRA) of the calf station at 3.0 T: intraindividual comparison of non-enhanced ECG-gated flow-dependent MRA, continuous table movement MRA and time-resolved MRA
    Stefan Haneder
    Ulrike I. Attenberger
    Philipp Riffel
    Thomas Henzler
    Stefan O. Schoenberg
    Henrik J. Michaely
    European Radiology, 2011, 21 : 1452 - 1461
  • [3] Magnetic resonance angiography (MRA) of the calf station at 3.0 T: intraindividual comparison of non-enhanced ECG-gated flow-dependent MRA, continuous table movement MRA and time-resolved MRA
    Haneder, Stefan
    Attenberger, Ulrike I.
    Riffel, Philipp
    Henzler, Thomas
    Schoenberg, Stefan O.
    Michaely, Henrik J.
    EUROPEAN RADIOLOGY, 2011, 21 (07) : 1452 - 1461
  • [4] A Novel 2D Transfer Function for the Volume Rendering of Blood Vessels in 3D Magnetic Resonance Angiography (MRA)
    Li, Xiankui
    Lan, Shouren
    Zhang, Zhijun
    Wang, Lisheng
    8TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2014), 2014, : 140 - 146
  • [5] Low-Dose 3D Time-Resolved Magnetic Resonance Angiography (MRA) of the Supraaortic Arteries: Correlation With High Spatial Resolution 3D Contrast-Enhanced MRA
    Lee, Youn-Joo
    Laub, Gerhard
    Jung, So-Lyung
    Yoo, Won-Jong
    Kim, Young-Joo
    Ahn, Kook-Jin
    Kim, Bum-Soo
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (01) : 71 - 76
  • [6] 3D Time-Resolved MR Angiography (MRA) of the Carotid Arteries with Time-Resolved Imaging with Stochastic Trajectories: Comparison with 3D Contrast-Enhanced Bolus-Chase MRA and 3D Time-Of-Flight MRA
    Lim, R. P.
    Shapiro, M.
    Wang, E. Y.
    Law, M.
    Babb, J. S.
    Rueff, L. E.
    Jacob, J. S.
    Kim, S.
    Carson, R. H.
    Mulholland, T. P.
    Laub, G.
    Hecht, E. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (10) : 1847 - 1854
  • [7] Combination 3D TOP with 2D PC MRA techique for cerebral blood flow volume measurement
    Guo, G.
    Wu, R. H.
    Zhang, Y. P.
    Guan, J. T.
    Guo, Y. L.
    Cheng, Y.
    terBrugge, K.
    Mikulis, D. J.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3946 - +
  • [8] Non-contrast-enhanced MR-angiography (MRA) of lower extremity peripheral arterial disease at 3 tesla: Examination time and diagnostic performance of 2D quiescent-interval single-shot MRA vs. 3D fast spin-Echo MRA
    Knobloch, Gesine
    Lauff, Marie-Teres
    Hanke, Moritz
    Schwenke, Carsten
    Hamm, Bernd
    Wagner, Moritz
    MAGNETIC RESONANCE IMAGING, 2021, 76 : 17 - 25
  • [9] Magnetic resonance angiography (MRA) of internal carotid arteries: Breath-hold Gd-enhanced 3D FISP versus unenhanced 2D or 3D TOF techniques, using digital subtraction angiography as a gold standard
    Zandrino, F
    Sardanelli, F
    Parodi, R
    Delfino, L
    De Caro, G
    RADIOLOGY, 1998, 209P : 427 - 427
  • [10] Three-dimensional time-of-flight (3D TOF) magnetic resonance angiography (MRA) and contrast-enhanced MRA of intracranial aneurysms treated with platinum coils
    Wikstrom, J.
    Ronne-Engstrom, E.
    Gal, G.
    Enblad, P.
    Tovi, M.
    ACTA RADIOLOGICA, 2008, 49 (02) : 190 - 196