Comparison of GC-MS/MS and LC-MS/MS for the analysis of hormones and pesticides in surface waters: advantages and pitfalls

被引:0
|
作者
He, Ping [1 ]
Aga, Diana S. [1 ]
机构
[1] SUNY Buffalo, Dept Chem, Buffalo, NY 14260 USA
关键词
ENDOCRINE-DISRUPTING CHEMICALS; SOLID-PHASE EXTRACTION; WAY-ROUND IONIZATION; LIQUID-CHROMATOGRAPHY; DRINKING-WATER; WASTE-WATER; MASS-SPECTROMETRY; ACIDIC PHARMACEUTICALS; SMALLMOUTH BASS; POTOMAC RIVER;
D O I
10.1039/c8ay02774a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The occurrence of endocrine disrupting chemicals (EDCs) in aquatic environments has long been a concern because of their threat to human and aquatic health. Liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) and gas chromatography coupled with tandem mass spectrometry (GC-MS/ MS) were optimized and compared for the detection of potential EDCs in order to examine the advantages and limitations of these commonly used instrumental methods in environmental analysis. The comparison between the two methods indicated that the performance and analytical results were not significantly different, except for the analysis of legacy organochlorine pesticides, such as dichlorodiphenyltrichloroethane (DDT) and its metabolites, where GC-MS/MS outperformed LC-MS/MS. However, because of the very low water solubility of these compounds they are less likely to be found in surface water samples, and they were therefore removed from the list of target analytes in the LC-MS/MS method. On the other hand, by using LC-MS/MS, highly water-soluble EDCs such as estrogens and their conjugates were simultaneously analyzed with the currently registered pesticides without the need for derivatization. In this study, an optimized procedure for solvent exchange of sample extracts originally dissolved in ethyl acetate (for GC-MS/MS) is described in order to prepare them for LC-MS/MS analysis. Quantitative analysis using LC-MS/MS was developed for the detection of potential EDCs including estrogens, pesticides, and industrial chemicals. Scheduled selected reaction monitoring acquisition in LC-MS/MS assured the optimum sensitivity of trace analysis. Electrospray positive and negative ionizations were performed in a single run by using wrong-way-round ionization employing a pH 10 mobile phase. Limits of detection ranging from 0.4 to 6 ng L-1 for all the target compounds could be achieved using the developed LC-MS/MS method. Recoveries (n = 3) for most of the compounds were above 70% with a relative standard deviation below 20%. The validated LC-MS/MS method was applied to natural river water samples and the results showed no significant difference from those obtained using GC-MS/MS.
引用
收藏
页码:1436 / 1448
页数:13
相关论文
共 50 条
  • [1] Multiresidue Analysis of Pesticides in Moringa Pods by GC-MS/MS and LC-MS/MS
    Dutta, Anirban
    Hingmire, Sandip
    Banerjee, Kaushik
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2020, 103 (06) : 1486 - 1497
  • [2] Analysis of neurosterols by GC-MS and LC-MS/MS
    Griffiths, William J.
    Wang, Yuqin
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (26): : 2778 - 2805
  • [3] Finding of pesticides in fashionable fruit juices by LC-MS/MS and GC-MS/MS
    Tran, Kevin
    Eide, David
    Nickols, Susan M.
    Cromer, Michele R.
    Sabaa-Srur, Armando
    Smith, Robert E.
    [J]. FOOD CHEMISTRY, 2012, 134 (04) : 2398 - 2405
  • [4] Determination of 355 Pesticides in Lemon and Lemon Juice by LC-MS/MS and GC-MS/MS
    Aslantas, Sule
    Golge, Ozgur
    Gonzalez-Curbelo, Miguel Angel
    Kabak, Bulent
    [J]. FOODS, 2023, 12 (09)
  • [5] LC-MS/MS AND GC-MS(/MS) BASED STEROIDOMICS
    Wudy, S. A.
    Sanchez-Guijo, A.
    Hartmann, M. F.
    [J]. REPRODUCTION IN DOMESTIC ANIMALS, 2014, 49 : 47 - 47
  • [6] Residue analysis of 500 high priority pesticides: Better by GC-MS or LC-MS/MS?
    Alder, Lutz
    Greulich, Kerstin
    Kempe, Guenther
    Vieth, Barbel
    [J]. MASS SPECTROMETRY REVIEWS, 2006, 25 (06) : 838 - 865
  • [7] Analysis of 136 Pesticides in Avocado Using a Modified QuEChERS Method with LC-MS/MS and GC-MS/MS
    Chamkasem, Narong
    Ollis, Lisa W.
    Harmon, Tiffany
    Lee, Sookwang
    Mercer, Greg
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (10) : 2315 - 2329
  • [8] The best MS option: GC-MS and LC-MS
    Sheehan, TL
    [J]. AMERICAN LABORATORY, 2002, 34 (18) : 40 - +
  • [9] Identification of novel pesticides and impurities by the combination of LC-MS with GC-MS analysis
    Zhang, SY
    Geng, Y
    Guo, YL
    Wang, H
    Lü, L
    [J]. CHINESE JOURNAL OF CHEMISTRY, 2005, 23 (07) : 870 - 874
  • [10] Phytochemical analysis in Alternanthera brasiliana by LC-MS/MS and GC-MS
    de Alencar Filho, Jose M. T.
    Teixeira, Hyany A. P.
    Sampaio, Pedrita A.
    Pereira, Emanuella C. V.
    e Amariz, Isabela A.
    Rolim Neto, Pedro J.
    Rolim, Larissa A.
    da Cruz Araujo, Edigenia C.
    [J]. NATURAL PRODUCT RESEARCH, 2020, 34 (03) : 429 - 433