Toluene Diisocyanate Emission to Air and Migration to a Surface from a Flexible Polyurethane Foam

被引:11
|
作者
Vangronsveld, Erik [1 ]
Berckmans, Steven [1 ]
Spence, Mark [2 ]
机构
[1] Huntsman Europe BVBA, B-3078 Everberg, Belgium
[2] Int Isocyanate Inst, Manchester M1 6LT, Lancs, England
来源
ANNALS OF OCCUPATIONAL HYGIENE | 2013年 / 57卷 / 05期
关键词
air emission; FLEC cell; flexible foam; micro-chamber; migration; polyurethane; toluene diisocyanate; INDOOR USE; ISOCYANATES;
D O I
10.1093/annhyg/mes105
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Flexible polyurethane foam (FPF) is produced from the reaction of toluene diisocyanate (TDI) and polyols. Because of the potential for respiratory sensitization following exposure to TDI, concerns have been raised about potential consumer exposure to TDI from residual free TDI in FPF products. Limited and conflicting results exist in the literature concerning the presence of unreacted TDI remaining in FPF as determined by various solvent extraction and analysis techniques. Because residual TDI results are most often intended for application in assessment of potential human exposure to TDI from FPF products, testing techniques that more accurately simulated human contact with foam were designed. To represent inhalation exposure to TDI from polyurethane foam, a test that measured the emission of TDI to air was conducted. For simulation of human dermal exposure to TDI from polyurethane foam, a migration test technique was designed. Emission of TDI to air was determined for a representative FPF using three different emission test cells. Two were commercially available cells that employ air flow over the surface of the foam [the Field and Laboratory Emission Cell (FLEC) and the Micro-Chamber/Thermal Extraction cell]. The third emission test cell was of a custom design and features air flow through the foam sample rather than over the foam surface. Emitted TDI in the air of the test cells was trapped using glass fiber filters coated with 1-(2-methoxyphenyl)-piperazine (MP), a commonly used derivatizing agent for diisocyanates. The filters were subsequently desorbed and analyzed by liquid chromatography/mass spectrometry. Measurement of TDI migration from representative foam was accomplished by placing glass fiber filters coated with MP on the outer surfaces of a foam disk and then compressing the filters against the disk using a clamping apparatus for periods of 8 and 24 h. The sample filters were subsequently desorbed and analyzed in the same manner as for the emission tests. Although the foam tested had detectable levels of solvent-extractable TDI (56ng TDI g(1) foam for the foam used in emissions tests; 2402800ng TDI g(1) foam for the foam used in migration tests), no TDI was detected in any of the emission or migration tests. Method detection limits (MDLs) for the emissions tests ranged from 0.03 to 0.5ng TDI g(1) foam (0.0020.04ng TDI cm(2) of foam surface), whereas those for the migration tests were 0.73ng TDI g(1) foam (0.16ng TDI cm(2) of foam surface). Of the three emission test methods used, the FLEC had the lowest relative MDLs (by a factor of 310) by virtue of its high chamber loading factor. In addition, the FLEC cell offers well-established conformity with emission testing standard methods.
引用
收藏
页码:650 / 661
页数:12
相关论文
共 50 条
  • [41] SMALL-ANGLE X-RAY-SCATTERING FROM SULFONATED POLYURETHANE IONOMERS BASED ON TOLUENE DIISOCYANATE
    DING, YS
    REGISTER, RA
    YANG, CZ
    COOPER, SL
    POLYMER, 1989, 30 (07) : 1213 - 1220
  • [42] 1H nuclear magnetic resonance study of polyurethane prepolymers from toluene diisocyanate and polypropylene glycol
    Pegoraro, M
    Galbiati, A
    Ricca, G
    JOURNAL OF APPLIED POLYMER SCIENCE, 2003, 87 (03) : 347 - 357
  • [43] APPLICATION OF POLYURETHANE FOAM FOR SAMPLING VOLATILE MUTAGENS FROM AMBIENT AIR
    DERAAT, WK
    SCHULTING, FL
    BURGHARDT, E
    DEMEIJERE, FA
    SCIENCE OF THE TOTAL ENVIRONMENT, 1987, 63 : 175 - 189
  • [44] Risk assessment-based verification of the CertiPUR™ limit values for toluene diamine and methylene dianiline in flexible polyurethane foam
    de Kort, Patrick
    Jensen, Elke
    Spence, Mark W.
    Plehiers, Patrick M.
    TOXICOLOGY AND INDUSTRIAL HEALTH, 2024, 40 (03) : 104 - 116
  • [45] Flexible Polyurethane Foam Synthesis and Characterization Obtained from Maleinizated Castor Oil
    Mazo, Paula
    Rios, Luis A.
    Estenoz, Diana
    POLIMEROS-CIENCIA E TECNOLOGIA, 2009, 19 (02): : 149 - 154
  • [46] EFFECT OF FOAM AGE ON TOXICITY OF PYROLYSIS GASES FROM POLYURETHANE FLEXIBLE FOAMS
    HILADO, CJ
    MURPHY, RM
    JOURNAL OF COMBUSTION TOXICOLOGY, 1978, 5 (02): : 239 - 247
  • [47] Copper-amine complex solution as a low-emission catalyst for flexible polyurethane foam preparation
    Sridaeng, Duangruthai
    Sukkaneewat, Benjatham
    Chueasakol, Nuttawut
    Chantarasiri, Nuanphun
    E-POLYMERS, 2015, 15 (02): : 119 - 126
  • [48] Biomarkers in hydrolysed urine, plasma and erythrocytes among workers exposed to thermal degradation products from toluene diisocyanate foam
    Lind, P
    Dalene, M
    Tinnerberg, H
    Skarping, G
    ANALYST, 1997, 122 (01) : 51 - 56
  • [49] Thermal decomposition of flexible polyurethane foam under nitrogen and air atmospheres: Thermogravimetric analysis by ETp method
    Zhu, Hong
    Wang, Zhenzhen
    Liu, Naian
    Gao, Wei
    Xie, Xiaodong
    Huang, Mengzhen
    THERMOCHIMICA ACTA, 2023, 727
  • [50] EVALUATION OF CONSUMER RISK RESULTING FROM EXPOSURE AGAINST DIPHENYLMETHANE-4,4′-DIISOCYANATE (MDI) FROM POLYURETHANE FOAM
    Hoffmann, Hans-Dieter