Development and evaluation of an inhalable bioaerosol manifold sampler

被引:0
|
作者
Gao, PF
Dillon, HK
Farthing, WE
机构
[1] UNIV ALABAMA,DEPT ENVIRONM HLTH SCI,BIRMINGHAM,AL 35294
[2] SO RES INST,BIRMINGHAM,AL 35205
来源
关键词
aerosol sampler; bioaerosol; inhalable size fraction; microscopy; sampling;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper describes the development and evaluation of an inhalable bioaerosol manifold sampler for the collection of replicate samples over sequential sampling periods. Wind tunnel experiments at wind velocities less than or equal to 0.6 m/sec (less than or equal to similar to 120 ft/min) and at a sampling velocity of 0.6 m/sec yielded sampling efficiencies within 10% of the American Conference of Governmental Industrial Hygienists' inhalable curve up to particle diameters for about 18 mu m and efficiencies within 18% for diameters up to 26 mu m. At wind velocities greater than or equal to 0.6 m/sec, a sampling velocity of 0.8 m/sec yielded efficiencies that were within 15% of the inhalable curve up to diameters of about 22 mu m and within 20% for diameters up to 25 mu m. Microscopic counts of 15.6-mu m and 25.6-mu m monodisperse polystyrene beads aerosolized in the wind tunnel and collected with the manifold sampler yielded precise concentrations (pooled CV=9.0 and 5.3%, respectively) averaging 115% and 92%, respectively of measurements with the APS Model 3310 aerodynamic particle sizer. Field tests in a cotton dust environment demonstrated the ability to generate a time/concentration profile of fungal spores similar to that indicated for cotton dust levels determined with horizontal elutriators. Cotton dust was sampled efficiently while cotton fibers were excluded. Field tests on a dairy farm indicated no statistically significant bias (p=0.72) between spore concentrations determined with the manifold sampler and concentrations determined through a central test port.
引用
收藏
页码:196 / 206
页数:11
相关论文
共 50 条
  • [21] Evaluation of a bioaerosol sampler for indoor environmental surveillance of Severe Acute Respiratory Syndrome Coronavirus 2
    Horve, Patrick Finn
    Dietz, Leslie
    Northcutt, Dale
    Stenson, Jason
    Van den Wymelenberg, Kevin
    PLOS ONE, 2021, 16 (11):
  • [22] Development of an improved methodology to detect infectious airborne influenza virus using the NIOSH bioaerosol sampler
    Cao, G.
    Noti, J. D.
    Blachere, F. M.
    Lindsley, W. G.
    Beezhold, D. H.
    JOURNAL OF ENVIRONMENTAL MONITORING, 2011, 13 (12): : 3321 - 3328
  • [23] Performance characteristics of the button personal inhalable aerosol sampler
    Aizenberg, V
    Grinshpun, SA
    Willeke, K
    Smith, J
    Baron, PA
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 2000, 61 (03): : 398 - 404
  • [24] Improvements to the design and performance of an ambient inhalable aerosol sampler
    Upton, S.L.
    Mark, D.
    Hall, D.J.
    Journal of Aerosol Science, 1992, 23 (SUPPL 1)
  • [25] Sampling characteristics of modified personal inhalable sampler inlets
    Stancliffe, J.D.
    Kenny, L.C.
    Journal of Aerosol Science, 1997, 28 (SUPPL. 1)
  • [26] Development and initial testing of an active low-power, ferroelectric film-based bioaerosol sampler
    Grogan, Sydonia N. C. M.
    Han, Taewon T.
    Mainelis, Gediminas
    AEROSOL SCIENCE AND TECHNOLOGY, 2022, 56 (12) : 1132 - 1145
  • [27] The Suitability of the IOM Foam Sampler for Bioaerosol Sampling in Occupational Environments
    Haatainen, Susanna
    Laitinen, Juha
    Linnainmaa, Markku
    Reponen, Tiina
    Kalliokoski, Pentti
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2010, 7 (01) : 1 - 6
  • [28] Field testing of a personal size-selective bioaerosol sampler
    Kenny, LC
    Bowry, A
    Crook, B
    Stancliffe, JD
    ANNALS OF OCCUPATIONAL HYGIENE, 1999, 43 (06): : 393 - 404
  • [29] PERFORMANCE OF BIOAEROSOL SAMPLERS - COLLECTION CHARACTERISTICS AND SAMPLER DESIGN CONSIDERATIONS
    NEVALAINEN, A
    PASTUSZKA, J
    LIEBHABER, F
    WILLEKE, K
    ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1992, 26 (04): : 531 - 540
  • [30] A collaborative European study of personal inhalable aerosol sampler performance
    Kenny, LC
    Aitken, R
    Chalmers, C
    Fabries, JF
    GonzalezFernandez, E
    Kromhout, H
    Liden, G
    Mark, D
    Riediger, G
    Prodi, V
    ANNALS OF OCCUPATIONAL HYGIENE, 1997, 41 (02): : 135 - 153