Establishment of a mouse gastrointestinal stromal tumour model and evaluation of response to imatinib by small animal positron emission tomography

被引:0
|
作者
Prenen, H
Deroose, C
Vermaelen, P
Sciot, R
Debiec-Rychter, M
Stroobants, S
Mortelmans, L
Schöffski, P
Van Oosterom, A
机构
[1] Univ Hosp Gasthuisberg, Dept Gen Med Oncol, Expt Oncol Lab, B-3000 Louvain, Belgium
[2] Catholic Univ Louvain, LEO, Dept Gen Med Oncol, B-3000 Louvain, Belgium
[3] Catholic Univ Louvain, Dept Nucl Med, B-3000 Louvain, Belgium
[4] Catholic Univ Louvain, Dept Pathol, B-3000 Louvain, Belgium
[5] Catholic Univ Louvain, Ctr Human Genet, B-3000 Louvain, Belgium
关键词
imatinib mesylate; GIST; mouse model; small animal PET;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Gastrointestinal stromal tumours (GIST) predominantly express activating mutations of the KIT tyrosine kinase receptor and are successfully treated with imatinib mesylate, a KIT inhibitor. As resistance to imatinib causes therapy failure, our aim was to develop an in vivo GIST model to evaluate KIT inhibitors and monitor therapy with small animal positron emission tomography (PET). Materials and Methods: The first mouse model of GIST xenografts was successfully established by injecting GIST882 cells subcutaneously into nude mice. Results: Using the small animal PET, FDG tip-take in xenografts was significantly decreased after 24 h of treatment with imatinib, which correlated with a response to treatment, e.g., with a decrease in tumour volume, the inhibition of KIT and downstream intermediate phosphorylation and arrest of tumour cell proliferation as evaluated after 7 days of treatment. Conclusion: This model is useful to study imatinib resistance and to evaluate novel targeted therapies.
引用
收藏
页码:1247 / 1252
页数:6
相关论文
共 50 条
  • [31] Small animal positron emission tomography imaging and in vivo studies of atherosclerosis
    Hag, Anne Mette Fisker
    Ripa, Rasmus Sejersten
    Pedersen, Sune Folke
    Bodholdt, Rasmus Poul
    Kjaer, Andreas
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2013, 33 (03) : 173 - 185
  • [32] Characterisation of arrays of avalanche photodiodes for small animal positron emission tomography
    Mosset, JB
    Saladino, S
    Loude, JF
    Morel, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 504 (1-3): : 325 - 330
  • [33] Positron Emission Tomography as a Surrogate Marker for Evaluation of Treatment Response in Patients with Desmoid Tumors under Therapy with Imatinib
    Kasper, Bernd
    Dimitrakopoulou-Strauss, Antonia
    Pilz, Lothar R.
    Strauss, Ludwig G.
    Sachpekidis, Christos
    Hohenberger, Peter
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [34] Positron emission tomography image on evaluating intraperitoneal dissemination of malignant gastrointestinal stromal tumor
    Kobayashi, Yoshinao
    Nakao, Makoto
    Konishi, Masayshi
    Urawa, Naohito
    Iwasa, Motoh
    Kaito, Masahiko
    Adachi, Yukihiko
    HEPATO-GASTROENTEROLOGY, 2008, 55 (84) : 895 - 897
  • [35] Use of positron emission tomography for staging, preoperative response assessment and posttherapeutic evaluation in children with Wilms tumour
    Misch, Daniel
    Steffen, Ingo G.
    Schoenberger, Stefan
    Voelker, Thomas
    Furth, Christian
    Stoever, Brigitte
    Hautzel, Hubertus
    Henze, Guenter
    Amthauer, Holger
    Denecke, Timm
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (09) : 1642 - 1650
  • [36] Use of positron emission tomography for staging, preoperative response assessment and posttherapeutic evaluation in children with Wilms tumour
    Daniel Misch
    Ingo G. Steffen
    Stefan Schönberger
    Thomas Voelker
    Christian Furth
    Brigitte Stöver
    Hubertus Hautzel
    Günter Henze
    Holger Amthauer
    Timm Denecke
    European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35 : 1642 - 1650
  • [37] A Systematic Review On Response Evaluation With Positron Emission Tomography / Computed Tomography
    Ehlers, K.
    Gerke, O.
    Motschall, E.
    Hoilund-Carlsen, P. F.
    Vach, W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S446 - S446
  • [38] Therapy Response Evaluation with Positron Emission Tomography-Computed Tomography
    Segall, George M.
    SEMINARS IN ULTRASOUND CT AND MRI, 2010, 31 (06) : 490 - 495
  • [39] Metabolomic and transcriptomic response to imatinib treatment of gastrointestinal stromal tumour in xenograft-bearing mice
    Macioszek, Szymon
    Dudzik, Danuta
    Bartoszewski, Rafal
    Stokowy, Tomasz
    Lambrechts, Diether
    Boeckx, Bram
    Wozniak, Agnieszka
    Schoffski, Patrick
    Markuszewski, Michal J.
    TRANSLATIONAL ONCOLOGY, 2023, 30
  • [40] Experimental Evaluation of Depth-of-Interaction Correction in a Small-Animal Positron Emission Tomography Scanner
    Green, Michael V.
    Ostrow, Harold G.
    Seidel, Jurgen
    Pomper, Martin G.
    MOLECULAR IMAGING, 2010, 9 (06): : 311 - 318