Assessment of Total Hip Arthroplasty by Means of Computed Tomography 3D Models and Fracture Risk Evaluation

被引:16
|
作者
Gargiulo, Paolo [1 ,2 ]
Petursson, Throstur [2 ]
Magnusson, Benedikt [2 ]
Bifulco, Paolo [6 ]
Cesarelli, Mario [6 ]
Izzo, Gianluca Mario [6 ]
Magnusdottir, Gigja [3 ]
Halldorsson, Gretar [3 ]
Ludvigsdottir, Gudbjoerg K. [3 ]
Tribel, Jan [4 ]
Jonsson, Halldor, Jr. [4 ,5 ]
机构
[1] Landspitali Univ Hosp, Dept Sci Educ & Innovat, IS-108 Reykjavik, Iceland
[2] Reykjavik Univ, Dept Biomed Engn, Reykjavik, Iceland
[3] Landspitali Hosp, Rehabil Clin Grensas, Reykjavik, Iceland
[4] Landspitali Hosp, Orthopaed Clin, Reykjavik, Iceland
[5] Univ Iceland, Fac Med, Reykjavik, Iceland
[6] Univ Naples Federico II, Dept Biomed Elect & Telecommun Engn, Naples, Italy
关键词
Total hip arthroplasty; Computed tomography 3D models; Bone mineral density; Finite element analysis; Cemented and noncemented implants; Fracture risk index; BONE-MINERAL DENSITY; ELECTRICAL-STIMULATION; MUSCLE; SEGMENTATION; REPLACEMENT;
D O I
10.1111/aor.12033
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Total hip arthroplasty (THA) can be achieved by using a cemented or noncemented prosthesis. Besides patient's age, weight, and other clinical signs, the evaluation of the quality of the bones is a crucial parameter on which orthopedic surgeons base the choice between cemented and noncemented THA. Although bone density generally decreases with age and a cemented THA is preferred for older subjects, the bone quality of a particular patient should be quantitatively evaluated. This study proposes a new method to quantitatively measure bone density and fracture risk by using 3D models extracted by a preoperative computed tomography (CT) scan of the patient. Also, the anatomical structure and compactness of the quadriceps muscle is computed to provide a more complete view. A spatial reconstruction of the tissues is obtained by means of CT image processing, then a detailed 3D model of bone mineral density of the femur is provided by including quantitative CT density information (CT must be precalibrated). A finite element analysis will provide a map of the strains around the proximal femur socket when solicited by typical stresses caused by an implant. The risk for structural failure due to press-fitting and compressive stress during noncemented THA surgery was estimated by calculating a bone fracture risk index (ratio between actual compressive stress and estimated failure stress of the bone). A clinical trial was carried out including 36 volunteer patients (ages 22-77) who underwent unilateral THA surgery for the first time: 18 received a cemented implant and 18 received a noncemented implant. CT scans were acquired before surgery, immediately after, and after 12 months. Bone and quadriceps density results were higher in the healthy leg in about 80% of the cases. Bone and quadriceps density generally decrease with age but mineral density may vary significantly between patients. Preliminary results indicate the highest fracture risk at the calcar and the lowest at the intertrocanteric line, with some difference between patients. An analysis of the results suggest that this methodology can be a valid noninvasive decision support tool for THA planning; however, further analyses are needed to tune the technique and to allow clinical applications. Combination with gait analysis data is planned.
引用
收藏
页码:567 / 573
页数:7
相关论文
共 50 条
  • [21] EVALUATION OF BIOMECHANICAL MODELS FOR THE PLANNING OF TOTAL HIP ARTHROPLASTY
    Asseln, M.
    Eschweiler, J.
    Damm, P.
    Al Hares, G.
    Bergmann, G.
    Tingart, M.
    Radermacher, K.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [22] Performance of radiography and single-photon emission computed tomography/computed tomography in painful total hip arthroplasty and impact on arthroplasty survival
    Schuldt, Anna
    Lehnick, Dirk
    Agten, Christoph A.
    Beck, Martin
    Kist, Markus
    Bhure, Ujwal
    Perez Lago, Maria del Sol
    Strobel, Klaus
    NUCLEAR MEDICINE COMMUNICATIONS, 2020, 41 (09) : 875 - 882
  • [23] Fracture Risk Assessment Tool Scores and Radiographical Bone Measurements in Total Hip Arthroplasty Patients
    Wang, Zhaorui
    Tutaworn, Teerapat
    Wishman, Mark D.
    Levin, Justin E.
    Hentschel, Isabelle G.
    Lane, Joseph M.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (12): : 2381 - 2386
  • [24] Lower Bone Density on Preoperative Computed Tomography Predicts Periprosthetic Fracture Risk in Total Ankle Arthroplasty
    Cody, Elizabeth A.
    Lachman, James R.
    Gausden, Elizabeth B.
    Nunley, James A.
    Easley, Mark E.
    FOOT & ANKLE INTERNATIONAL, 2019, 40 (01) : 1 - 8
  • [25] A New Technique for Measuring Wear in Total Hip Arthroplasty Using Computed Tomography
    Goldvasser, Dov
    Noz, Marilyn E.
    Maguire, G. Q., Jr.
    Olivecrona, Henrik
    Bragdon, Charles R.
    Makhau, Henrik
    JOURNAL OF ARTHROPLASTY, 2012, 27 (09): : 1636 - 1640
  • [26] THE USE OF PREOPERATIVE COMPUTED-TOMOGRAPHY SCANNING IN TOTAL HIP-ARTHROPLASTY
    BERMAN, AT
    MCGOVERN, KM
    PARET, RS
    YANICKO, DR
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1987, (222) : 190 - 196
  • [27] Application of Computed Tomography-Based Navigation for Revision Total Hip Arthroplasty
    Nakamura, Nobuo
    Nishii, Takashi
    Kitada, Makoto
    Iwana, Daiki
    Sugano, Nobuhiko
    JOURNAL OF ARTHROPLASTY, 2013, 28 (10): : 1806 - 1810
  • [28] 3D Printing Navigation Template Used in Total Hip Arthroplasty for Developmental Dysplasia of the Hip
    Yan, Liang
    Wang, Peng
    Zhou, Haibin
    INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (06) : 856 - 862
  • [29] 3D Printing Navigation Template Used in Total Hip Arthroplasty for Developmental Dysplasia of the Hip
    Liang Yan
    Peng Wang
    Haibin Zhou
    Indian Journal of Orthopaedics, 2020, 54 : 856 - 862
  • [30] Computed tomography evaluation of hip geometry restoration after total hip resurfacing
    Arnould, A.
    Boureau, F.
    Benad, K.
    Pasquier, G.
    Migaud, H.
    Girard, J.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (05) : 571 - 575