Metrological investigation of radiation filtration in x-ray computed tomography

被引:0
|
作者
Kourra, N. [1 ]
Warnett, J. A. [1 ]
Attridge, A. [1 ]
Williams, M. A. [1 ]
机构
[1] Univ Warwick, WMG, Coventry CV4 7AL, W Midlands, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
X-ray Computed Tomography (CT) is a non-destructive evaluation method that gains recognition in dimensional metrology applications. During a CT scan, 2D radiographs are collected that are then reconstructed to a 3D model which allows non-destructive evaluation of the specimen and assists with the characterisations of defects. This technology has the potential to provide information unobtainable by other non-destructive, non-contact techniques. There are numerous factors that can affect the CT measurement results with varying measurement uncertainty such as shifts and changes of x-ray focal spot, geometrical alignment issues and environmental issues. This study investigates the effect of physical pre and post filtration on the resultant dimensional measurements. Here, a calibrated specimen is used based on one of the considered designs for the proposed ISO 10360-11 CT for dimensional measurements. The resultant in local variations of grey values in the volume is measured for different thicknesses of copper filtering placed before and after the scanned specimen, and the resultant threshold dependent and independent measurements are evaluated. The results provide information that assists the selection of filtration in order to reduce measurement error and improve dimensional measurements, and also demonstrate that post filtration should be considered when scanning specimens that generate large amounts of scatter.
引用
收藏
页码:915 / 920
页数:6
相关论文
共 50 条
  • [31] Liposome Sterile Filtration Characterization via X-ray Computed Tomography and Confocal Microscopy
    Johnson, Thomas F.
    Jones, Kyle
    Iacoviello, Francesco
    Turner, Stephen
    Jackson, Nigel B.
    Zourna, Kalliopi
    Welsh, John H.
    Shearing, Paul R.
    Hoare, Mike
    Bracewell, Daniel G.
    [J]. MEMBRANES, 2021, 11 (11)
  • [32] Optimization of Incident X-Ray Source Spectrum Through Filtration for a Benchtop X-Ray Fluorescence Computed Tomography (XFCT) System
    Manohar, N.
    Jones, B.
    Cho, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [33] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    [J]. APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [34] Fluorescent x-ray computed tomography with synchrotron radiation using fan collimator
    Takeda, T
    Akiba, M
    Yuasa, T
    Kazama, M
    Hoshino, A
    Watanabe, Y
    Hyodo, K
    Dilmanian, FA
    Akatsuka, T
    Itai, Y
    [J]. PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 685 - 695
  • [35] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [36] X-ray Digital Radiography and Computed Tomography
    Morigi, Maria Pia
    Albertin, Fauzia
    [J]. JOURNAL OF IMAGING, 2022, 8 (05)
  • [37] STATISTICAL ASPECTS OF COMPUTED X-RAY TOMOGRAPHY
    CHESLER, DA
    PELC, NJ
    RIEDERER, SJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 130 - 131
  • [38] X-ray computed tomography of ultralightweight metals
    Winter, JM
    Green, RE
    Waters, AM
    Green, WH
    [J]. RESEARCH IN NONDESTRUCTIVE EVALUATION, 1999, 11 (04) : 199 - 211
  • [39] X-ray computed tomography for medical imaging
    Hiriyannaiah, HP
    [J]. IEEE SIGNAL PROCESSING MAGAZINE, 1997, 14 (02) : 42 - 59
  • [40] Microscopic x-ray luminescence computed tomography
    Zhang, Wei
    Zhu, Dianwen
    Zhang, Kun
    Li, Changqing
    [J]. MULTIMODAL BIOMEDICAL IMAGING X, 2015, 9316