MRI-based staging of hepatic fibrosis: Comparison of intravoxel incoherent motion diffusion-weighted imaging with magnetic resonance elastography

被引:65
|
作者
Ichikawa, Shintaro [1 ]
Motosugi, Utaroh [1 ]
Morisaka, Hiroyuki [1 ]
Sano, Katsuhiro [1 ]
Ichikawa, Tomoaki [1 ]
Enomoto, Nobuyuki [2 ]
Matsuda, Masanori [3 ]
Fujii, Hideki [3 ]
Onishi, Hiroshi [1 ]
机构
[1] Univ Yamanashi, Dept Radiol, Chuo, Yamanashi 4093898, Japan
[2] Univ Yamanashi, Dept Internal Med 1, Chuo, Yamanashi 4093898, Japan
[3] Univ Yamanashi, Dept Surg 1, Chuo, Yamanashi 4093898, Japan
关键词
hepatic fibrosis; diffusion-weighted imaging (DWI); intravoxel incoherent motion (IVIM); magnetic resonance elastography (MRE); magnetic resonance imaging (MRI); LIVER FIBROSIS; B VALUES; CIRRHOSIS; QUANTIFICATION; REPEATABILITY; FEASIBILITY; RISK;
D O I
10.1002/jmri.24760
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo evaluate the use of intravoxel incoherent motion (IVIM) imaging for staging hepatic fibrosis, and compare its staging ability with that of magnetic resonance elastography (MRE). Materials and MethodsThis study included 129 patients with pathologically staged liver fibrosis, and 53 patients with healthy livers. All patients underwent both MRE and IVIM imaging. Four diffusivity indices were calculated with 11 b-values; slow diffusion coefficient related to molecular diffusion (D), fast diffusion coefficient related to perfusion in micro-vessels (D*), perfusion-related diffusion fraction (f), and apparent diffusion coefficient (ADC). Receiver operating characteristic curve analysis was performed to determine the accuracy of IVIM imaging and MRE for staging hepatic fibrosis. ResultsD*, f, and ADC values decreased significantly with fibrosis stage (P < 0.0124), and liver stiffness increased (P < 0.0001). The Az value of MRE was significantly higher than that of D* for all fibrosis stages (D* vs. MRE for F1, 0.851 vs. 0.992 [P < 0.0001]; F2, 0.898 vs. 0.998 [P = 0.0003]; F3, 0.904 vs. 0.995 [P = 0.0004]; F4, 0.885 vs. 0.996 [P < 0.0001]). ConclusionIVIM imaging is a useful technique for evaluating hepatic fibrosis, but MRE is better able to discriminate fibrosis stages than IVIM imaging. J. Magn. Reson. Imaging 2015;42:204-210. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:204 / 210
页数:7
相关论文
共 50 条
  • [31] Determination of Malignancy and Characterization of Hepatic Tumor Type With Diffusion-Weighted Magnetic Resonance Imaging Comparison of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion-Derived Measurements
    Doblas, Sabrina
    Wagner, Mathilde
    Leitao, Helena S.
    Daire, Jean-Luc
    Sinkus, Ralph
    Vilgrain, Valerie
    Van Beers, Bernard E.
    [J]. INVESTIGATIVE RADIOLOGY, 2013, 48 (10) : 722 - 728
  • [32] Progress of intravoxel incoherent motion diffusion-weighted imaging in liver diseases
    Yun-Yun Tao
    Yi Zhou
    Ran Wang
    Xue-Qin Gong
    Jing Zheng
    Cui Yang
    Lin Yang
    Xiao-Ming Zhang
    [J]. World Journal of Clinical Cases, 2020, (15) : 3164 - 3176
  • [33] An Intravoxel Incoherent Motion Diffusion-Weighted Imaging Study of Prostate Cancer
    Shinmoto, Hiroshi
    Tamura, Chiharu
    Soga, Shigeyoshi
    Shiomi, Eisuke
    Yoshihara, Nobuyuki
    Kaji, Tatsumi
    Mulkern, Robert V.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (04) : W496 - W500
  • [34] Progress of intravoxel incoherent motion diffusion-weighted imaging in liver diseases
    Tao, Yun-Yun
    Zhou, Yi
    Wang, Ran
    Gong, Xue-Qin
    Zheng, Jing
    Yang, Cui
    Yang, Lin
    Zhang, Xiao-Ming
    [J]. WORLD JOURNAL OF CLINICAL CASES, 2020, 8 (15) : 3164 - U53
  • [35] Application of intravoxel incoherent motion diffusion-weighted imaging in hepatocellular carcinoma
    Zhou, Yi
    Zheng, Jing
    Yang, Cui
    Peng, Juan
    Liu, Ning
    Yang, Lin
    Zhang, Xiao-Ming
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2022, 28 (27) : 3334 - 3345
  • [36] Application of intravoxel incoherent motion diffusion-weighted imaging in hepatocellular carcinoma
    Yi Zhou
    Jing Zheng
    Cui Yang
    Juan Peng
    Ning Liu
    Lin Yang
    Xiao-Ming Zhang
    [J]. World Journal of Gastroenterology, 2022, (27) : 3334 - 3345
  • [37] Comparison of six fit algorithms for the intravoxel incoherent motion model of diffusion-weighted magnetic resonance imaging data of pancreatic cancer patients
    Gurney-Champion, Oliver J.
    Klaassen, Remy
    Froeling, Martijn
    Barbieri, Sebastiano
    Stoker, Jaap
    Engelbrecht, Marc R. W.
    Wilmink, Johanna W.
    Besselink, Marc G.
    Bel, Arjan
    van Laarhoven, Hanneke W. M.
    Nederveen, Aart J.
    [J]. PLOS ONE, 2018, 13 (04):
  • [38] Three-Tesla magnetic resonance elastography for hepatic fibrosis:Comparison with diffusion-weighted imaging and gadoxetic acid-enhanced magnetic resonance imaging
    Hee Sun Park
    Young Jun Kim
    Mi Hye Yu
    Won Hyeok Choe
    Sung Il Jung
    Hae Jeong Jeon
    [J]. World Journal of Gastroenterology, 2014, (46) : 17558 - 17567
  • [39] Three-Tesla magnetic resonance elastography for hepatic fibrosis: Comparison with diffusion-weighted imaging and gadoxetic acid-enhanced magnetic resonance imaging
    Park, Hee Sun
    Kim, Young Jun
    Yu, Mi Hye
    Choe, Won Hyeok
    Jung, Sung Il
    Jeon, Jeong
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (46) : 17558 - 17567
  • [40] Evaluation of Intravoxel Incoherent Motion Diffusion-Weighted Magnetic Resonance Imaging for Detection of Bowel Inflammation in Patients With Crohn Disease
    Yang, Hai-Jing
    Xi, Yu-Ling
    Guan, Xue-Ni
    Xie, Qian
    Rong, Lan
    Liang, Zong-Hui
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (05) : 755 - 761