Methods of constructing an individual calibration characteristic for working platinum resistance thermometers

被引:2
|
作者
Moiseeva, NP
机构
关键词
Physical Chemistry; Analytical Chemistry; Platinum; Temperature Measurement; Temperature Scale;
D O I
10.1023/A:1012314420995
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Methods recommended for calibrating working platinum resistance thermometers are considered. A simplified method of constructing an interpolation curve in the form of second- and third-degree polynomials, calculated from the results of a calibration of thermometers at fixed points of the temperature scale, is proposed and investigated. It is shown that the error of the method lies within the limits of the error of temperature measurements made with working resistance thermometers in the 0-660 degreesC range.
引用
收藏
页码:502 / 507
页数:6
相关论文
共 50 条
  • [21] The development of a primary laboratory for the calibration of standard platinum resistance thermometers
    Armstrong, S
    TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 351 - 356
  • [22] FIELD CALIBRATION OF PLATINUM RESISTANCE THERMOMETERS SERVING PROFILE MEASUREMENTS
    KOITZSCH, R
    DZINGEL, M
    ZEITSCHRIFT FUR METEOROLOGIE, 1985, 35 (03): : 171 - 174
  • [23] CONSTRUCTING AN INTERPOLATION FORMULA FOR PRIMARY-STANDARD AND WORKING-STANDARD HIGH-TEMPERATURE PLATINUM RESISTANCE THERMOMETERS
    MOISEEVA, NP
    MEASUREMENT TECHNIQUES USSR, 1993, 36 (08): : 906 - 910
  • [24] Modelling the calibration of the industrial platinum-resistance thermometers according to GUM
    Inseok Yang
    Kee Sool Gam
    Wukchul Joung
    Yong-Gyoo Kim
    Accreditation and Quality Assurance, 2013, 18 : 359 - 362
  • [25] A low temperature adiabatic calorimeter. The calibration of the platinum resistance thermometers
    Yost, DM
    Garner, CS
    Osborne, DW
    Rubin, TR
    Russell, H
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1941, 63 : 3488 - 3492
  • [26] Modelling the calibration of the industrial platinum-resistance thermometers according to GUM
    Yang, Inseok
    Gam, Kee Sool
    Joung, Wukchul
    Kim, Yong-Gyoo
    ACCREDITATION AND QUALITY ASSURANCE, 2013, 18 (04) : 359 - 362
  • [27] Calibration of industrial platinum resistance thermometers in thermostats (-40 °C to 420 °C)
    Constantin, Bordianu
    Chelidze, Yu, V
    Marina, Denisova
    Ibraev, Meirzhan
    Baghirov, Azer
    Hodzic, Nedzadeta
    Corman, Alev
    METROLOGIA, 2019, 56 (1A)
  • [28] Practical Calibration of Platinum Resistance Thermometers in the Range −190 °C to 0 °C
    J. De Lucas
    R. Benyon
    International Journal of Thermophysics, 2011, 32 : 2452 - 2465
  • [29] Practical Calibration of Platinum Resistance Thermometers in the Range -190 °C to 0 °C
    De Lucas, J.
    Benyon, R.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (11-12) : 2452 - 2465
  • [30] SIMPLE CALIBRATION PROCEDURES FOR PLATINUM RESISTANCE THERMOMETERS FROM 2.5 TO 14 K
    MCCRACKIN, FL
    CHANG, SS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1975, 46 (05): : 550 - 553