Circumferential or sectored beam arrangements for stereotactic body radiation therapy (SBRT) of primary lung tumors: Effect on target and normal-,structure dose-volume metrics

被引:2
|
作者
Rosenberg, Mara W. [1 ,2 ]
Kato, Catherine M. [3 ]
Carson, Kelly M. P. [4 ]
Matsunaga, Nathan M. [5 ]
Arao, Robert E. [6 ]
Doss, Emily J. [7 ]
McCracken, Charles L. [8 ]
Meng, Lu Z. [9 ]
Chen, Yiyi [6 ]
Laub, Wolfram U. [8 ,10 ]
Fuss, Martin [8 ,10 ]
Tanyi, James A. [8 ,10 ]
机构
[1] Broad Inst MIT & Harvard, Cambridge, MA USA
[2] Brandeis Univ, Dept Phys, Waltham, MA 02254 USA
[3] Macalester Coll, St Paul, MN 55105 USA
[4] Univ N Carolina, Chapel Hill, NC USA
[5] Santa Clara Univ, Santa Clara, CA 95053 USA
[6] Oregon Hlth & Sci Univ, Dept Publ Hlth & Prevent Med, Portland, OR 97239 USA
[7] Providence St Vincent Med Ctr, Dept Internal Med, Portland, OR USA
[8] Oregon Hlth & Sci Univ, Dept Radiat Med, Portland, OR 97239 USA
[9] Univ Calif Davis, Ctr Comprehens Canc, Dept Radiat Oncol, Sacramento, CA 95817 USA
[10] Oregon State Univ, Dept Nucl Engn & Radiat Hlth Phys, Corvallis, OR 97331 USA
关键词
Intensity-modulated radiotherapy; Intensity-modulated arc therapy; Stereotactic body radiotherapy; Beam configuration; CANCER; RADIOTHERAPY; TOXICITY; DELIVERY; RISK;
D O I
10.1016/j.meddos.2013.05.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To compare 2 beam arrangements, sectored (beam entry over ipsilateral hemithorax) vs circumferential (beam entry over both ipsilateral and contralateral lungs), for static-gantry intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques with respect to target and organs-at-risk (OAR) dose-volume metrics, as well as treatment delivery efficiency. Data from 60 consecutive patients treated using stereotactic body radiation therapy (SBRT) for primary non-small-cell lung cancer (NSCLC) formed the basis of this study. Four treatment plans were generated per data set: 1MRT/VMAT plans using sectored (-s) and circumferential (-c) configurations. The prescribed dose (PD) was 60 Gy in 5 fractions to 95% of the planning target volume (PTV) (maximum PTV dose 150% PD) for a 6-MV photon beam. Plan conformality, Rso (ratio of volume circumscribed by the 50% isodose line and the PTV), and D-2 CM (Dmax at a distance >2 cm beyond the PTV) were evaluated. For lungs, mean doses (mean lung dose [MLD1) and percent V-30/V-20/V(1)o/V-5 Gy were assessed. Spinal cord and esophagus D. and D5/D50 were computed. Chest wall (CW) Dmax and absolute V30/V20/V10/V5 Gy were reported. Sectored SBRT planning resulted in significant decrease in contralateral MLD and Vio/ Vs Gy, as well as contralateral CW Dn,a. and V(1)o/V-5 Gy (all p < 0.001). Nominal reductions of D. and Ds/ Dso for the spinal cord with sectored planning did not reach statistical significance for static-gantry IMRT, although VMAT metrics did show a statistically significant decrease (all p < 0.001). The respective measures for esophageal doses were significantly lower with sectored planning (p < 0.001). Despite comparable dose conformality, irrespective of planning configuration, Rso significantly improved with 1MRT-s/VMAT-c (p < 0.001/p = 0.008), whereas D2 cm significantly improved with VMAT-c (p < 0.001). Plan delivery efficiency improved with sectored technique (p < 0.001); mean monitor unit (MU)/cGy of PD decreased from 5.8 1.9 vs 5.3 - 1.7 (IMRT) and 2.7 0.4 vs 2.4 - 0.3 (VMAT). The sectored configuration achieves unambiguous dosimetric advantages over circumferential arrangement in terms of esophageal, contralateral CW, and contralateral lung sparing, in addition to being more efficient at delivery. (C) 2013 American Association of Medical Dosimetrists.
引用
收藏
页码:407 / 412
页数:6
相关论文
共 50 条
  • [21] Influence of target dose heterogeneity on dose sparing of normal tissue in peripheral lung tumor stereotactic body radiation therapy
    Wei, Zhigong
    Peng, Xingchen
    Wang, Yan
    Yang, Lianlian
    He, Ling
    Liu, Zheran
    Wang, Jingjing
    Mu, Xiaoli
    Li, Ruidan
    Xiao, Jianghong
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [22] Temporal Dose-Response of Normal Lung Tissue in Patients Treated with Stereotactic Body Radiation Therapy for Lung Tumors
    Diot, Q.
    Kavanagh, B.
    Gaspar, L.
    Raben, D.
    Stuhr, K.
    Miften, M.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [23] Characterization of target dose in Stereotactic Body Radiation Therapy (SBRT) of lung by direct measurment in anthropomorphic phantom and by Monte Carlo calculation
    Salter, B
    Rassiah, P
    Tanyi, J
    Cheng, C
    Fuss, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1716 - 1716
  • [24] A Novel Model to Predict the Overestimation of Pencil Beam Dose Calculation in Stereotactic Body Radiation Therapy of Lung Tumors
    Siddiqui, M. U.
    Fraser, C.
    Li, H.
    Liu, D.
    Wen, N.
    Kumar, S.
    Ajlouni, M.
    Levin, K.
    Movsas, B.
    Chetty, I.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S869 - S869
  • [25] Effect of Target Changes on Target Coverage and Dose to the Normal Brain in Fractionated Stereotactic Radiation Therapy for Metastatic Brain Tumors
    Miura, Hideharu
    Kenjo, Masahiro
    Doi, Yoshiko
    Ueda, Taro
    Nakao, Minoru
    Ozawa, Shuichi
    Nagata, Yasushi
    ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (06)
  • [26] Normal Tissue Dose Effect of Prescription Isodose Level Selection in Lung Stereotactic Body Radiation Therapy
    Zhang, Q.
    Lei, Y.
    Zheng, D.
    Zhu, X.
    Wahl, A.
    Lin, C.
    Zhou, S.
    Zhen, W.
    MEDICAL PHYSICS, 2015, 42 (06) : 3467 - 3467
  • [27] Respiratory Motion-Encompassing Planning Target Volume (ME-PTV) for Stereotactic Body Radiation Therapy (SBRT) of Lung Cancer
    Hossain, M.
    Shaikh, T. A.
    Jin, L.
    Turaka, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S897 - S897
  • [28] Changes in Dose-Volume Parameters of Stereotactic Body Radiation Therapy (SBRT) for Stage I Lung Cancer by Calculation Algorithms and Relationship With Outcome: Pencil Beam Convolution With Batho Power Law Versus Anisotropic Analytical Algorithm
    Otsuka, S.
    Baba, F.
    Miyakawa, A.
    Ishikura, S.
    Murai, T.
    Tamura, T.
    Shibamoto, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S618 - S618
  • [29] The influence of target and patient characteristics on the volume obtained from cone beam CT in lung stereotactic body radiation therapy
    Liu, Hong-Wei
    Khan, Rao
    D'Ambrosi, Rafael
    Krobutschek, Krista
    Nugent, Zoann
    Lau, Harold
    RADIOTHERAPY AND ONCOLOGY, 2013, 106 (03) : 312 - 316
  • [30] Target Dose Characterization by Monte Carlo versus Pencil Beam Algorithm for Lung Stereotactic Body Radiation Therapy (SBRT): A Preliminary Analysis in 20 Successfully Treated Patients
    Chen, A. Y.
    Li, Q.
    McNair, S.
    Xu, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S852 - S853