Circumferential or sectored beam arrangements for stereotactic body radiation therapy (SBRT) of primary lung tumors: Effect on target and normal-,structure dose-volume metrics

被引:2
|
作者
Rosenberg, Mara W. [1 ,2 ]
Kato, Catherine M. [3 ]
Carson, Kelly M. P. [4 ]
Matsunaga, Nathan M. [5 ]
Arao, Robert E. [6 ]
Doss, Emily J. [7 ]
McCracken, Charles L. [8 ]
Meng, Lu Z. [9 ]
Chen, Yiyi [6 ]
Laub, Wolfram U. [8 ,10 ]
Fuss, Martin [8 ,10 ]
Tanyi, James A. [8 ,10 ]
机构
[1] Broad Inst MIT & Harvard, Cambridge, MA USA
[2] Brandeis Univ, Dept Phys, Waltham, MA 02254 USA
[3] Macalester Coll, St Paul, MN 55105 USA
[4] Univ N Carolina, Chapel Hill, NC USA
[5] Santa Clara Univ, Santa Clara, CA 95053 USA
[6] Oregon Hlth & Sci Univ, Dept Publ Hlth & Prevent Med, Portland, OR 97239 USA
[7] Providence St Vincent Med Ctr, Dept Internal Med, Portland, OR USA
[8] Oregon Hlth & Sci Univ, Dept Radiat Med, Portland, OR 97239 USA
[9] Univ Calif Davis, Ctr Comprehens Canc, Dept Radiat Oncol, Sacramento, CA 95817 USA
[10] Oregon State Univ, Dept Nucl Engn & Radiat Hlth Phys, Corvallis, OR 97331 USA
关键词
Intensity-modulated radiotherapy; Intensity-modulated arc therapy; Stereotactic body radiotherapy; Beam configuration; CANCER; RADIOTHERAPY; TOXICITY; DELIVERY; RISK;
D O I
10.1016/j.meddos.2013.05.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To compare 2 beam arrangements, sectored (beam entry over ipsilateral hemithorax) vs circumferential (beam entry over both ipsilateral and contralateral lungs), for static-gantry intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques with respect to target and organs-at-risk (OAR) dose-volume metrics, as well as treatment delivery efficiency. Data from 60 consecutive patients treated using stereotactic body radiation therapy (SBRT) for primary non-small-cell lung cancer (NSCLC) formed the basis of this study. Four treatment plans were generated per data set: 1MRT/VMAT plans using sectored (-s) and circumferential (-c) configurations. The prescribed dose (PD) was 60 Gy in 5 fractions to 95% of the planning target volume (PTV) (maximum PTV dose 150% PD) for a 6-MV photon beam. Plan conformality, Rso (ratio of volume circumscribed by the 50% isodose line and the PTV), and D-2 CM (Dmax at a distance >2 cm beyond the PTV) were evaluated. For lungs, mean doses (mean lung dose [MLD1) and percent V-30/V-20/V(1)o/V-5 Gy were assessed. Spinal cord and esophagus D. and D5/D50 were computed. Chest wall (CW) Dmax and absolute V30/V20/V10/V5 Gy were reported. Sectored SBRT planning resulted in significant decrease in contralateral MLD and Vio/ Vs Gy, as well as contralateral CW Dn,a. and V(1)o/V-5 Gy (all p < 0.001). Nominal reductions of D. and Ds/ Dso for the spinal cord with sectored planning did not reach statistical significance for static-gantry IMRT, although VMAT metrics did show a statistically significant decrease (all p < 0.001). The respective measures for esophageal doses were significantly lower with sectored planning (p < 0.001). Despite comparable dose conformality, irrespective of planning configuration, Rso significantly improved with 1MRT-s/VMAT-c (p < 0.001/p = 0.008), whereas D2 cm significantly improved with VMAT-c (p < 0.001). Plan delivery efficiency improved with sectored technique (p < 0.001); mean monitor unit (MU)/cGy of PD decreased from 5.8 1.9 vs 5.3 - 1.7 (IMRT) and 2.7 0.4 vs 2.4 - 0.3 (VMAT). The sectored configuration achieves unambiguous dosimetric advantages over circumferential arrangement in terms of esophageal, contralateral CW, and contralateral lung sparing, in addition to being more efficient at delivery. (C) 2013 American Association of Medical Dosimetrists.
引用
收藏
页码:407 / 412
页数:6
相关论文
共 50 条
  • [1] Stereotactic Body Radiotherapy Beam (SBRT) Configuration On Target And Normal-structure Dose-volume Metrics
    Rosenberg, M.
    Carson, K.
    Kato, C. M.
    Meng, L. Z.
    Laub, W.
    Tanyi, J. A.
    Fuss, M.
    JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (09) : S259 - S259
  • [2] Dose-Volume Metrics Associated With Radiation Pneumonitis After Stereotactic Body Radiation Therapy for Lung Cancer
    Matsuo, Yukinori
    Shibuya, Keiko
    Nakamura, Mitsuhiro
    Narabayashi, Masaru
    Sakanaka, Katsuyuki
    Ueki, Nami
    Miyagi, Ken
    Norihisa, Yoshiki
    Mizowaki, Takashi
    Nagata, Yasushi
    Hiraoka, Masahiro
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (04): : E545 - E549
  • [3] DOSE-VOLUME ANALYSIS OF RADIATION LUNG INJURY AFTER STEREOTACTIC BODY RADIATION THERAPY
    Masciullo, S.
    Masi, L.
    Casamassima, F.
    Menichelli, C.
    Bonucci, I.
    Doro, R.
    RADIOTHERAPY AND ONCOLOGY, 2011, 98 : S44 - S44
  • [4] Dose-Volume Predictors of Radiation Pneumonitis After Lung Stereotactic Body Radiation Therapy (SBRT): Implications for Practice and Trial Design
    Moiseenko, Vitali
    Grimm, Jimm
    Yorke, Ellen
    Jackson, Andrew
    Yip, Anthony
    Minh-Phuong Huynh-Le
    Mahadevan, Anand
    Forster, Kenneth
    Milano, Michael T.
    Hattangadi-Gluth, Jona
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (10)
  • [5] Evaluation of Dose-Volume Metrics Associated With Local Recurrence After Stereotactic Body Radiation Therapy for Lung Cancer
    Matsuo, Y.
    Shibuya, K.
    Nakamura, M.
    Narabayashi, M.
    Sakanaka, K.
    Ueki, N.
    Mizowaki, T.
    Hiraoka, M.
    JOURNAL OF THORACIC ONCOLOGY, 2010, 5 (12) : S544 - S544
  • [6] Pulmonary Function Changes After Stereotactic Body Radiation Therapy (SBRT) for Lung Cancer and Correlation With Dose-Volume Parameters
    Takemoto, S.
    Shibamoto, Y.
    Hashizume, C.
    Miyakawa, A.
    Uchiyama, K.
    Baba, F.
    Mori, Y.
    Otsuka, S.
    Iwata, H.
    Yanagi, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E448 - E448
  • [7] Changes of Pulmonary Function and Correlation With Dose-Volume Parameters in Patients Undergoing Stereotactic Body Radiation Therapy (SBRT) for Lung Cancer
    Takemoto, S.
    Shibamoto, Y.
    Miyakawa, A.
    Hashizume, C.
    Uchiyama, K.
    Baba, F.
    Mori, Y.
    Otsuka, S.
    Iwata, H.
    Yanagi, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S557 - S557
  • [8] Predictors of Pulmonary and Other Thoracic Complications after Lung Stereotactic Body Radiotherapy (SBRT) for Primary or Metastatic Lung Tumors: Dose-volume Analysis
    Mangona, V.
    Grills, I. S.
    Yan, D.
    McInemey, E.
    Martin, S.
    Kestin, L. L.
    McGrath, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S161 - S161
  • [9] Analysis of Dose-Volume Metrics Associated with Radiation Pneumonitis after Stereotactic Body Radiotherapy for Lung Cancer
    Matsuo, Y.
    Shibuya, K.
    Narabayashi, M.
    Sakanaka, K.
    Nakamura, M.
    Mizowaki, T.
    Hiraoka, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S178 - S178
  • [10] Mean Dose in healthy lung for chest tumors treated with Stereotactic Body Radiation Therapy (SBRT)
    Monroy Anton, J. L.
    Asensio Martinez, M.
    Borreda Talon, V.
    Hernandis Barbera, J.
    Marco Collado, M.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S1001 - S1001