Forces and torques during fracture reduction:: Intraoperative measurements in the femur

被引:49
|
作者
Gösling, T
Westphal, R
Faülstich, J
Sommer, K
Wahl, F
Krettek, C
Hufner, T
机构
[1] Hannover Med Sch, Trauma Dept, D-30625 Hannover, Germany
[2] Tech Univ Carolo Wilhelmina Braunschweig, Inst Robot & Proc Control, D-38106 Braunschweig, Germany
关键词
fracture; reduction; femur; torque; force;
D O I
10.1002/jor.20045
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Reduction is a crucial step in fracture treatment. We determined intraoperative peak forces and torques during fracture reduction in seven patients with eight fractures of the femoral shaft. All fractures were temporarily stabilized by external fixation. Force and torque measurements were performed during the subsequent intramedullary nailing procedure. A three-dimensional load cell was attached to the distal femur fragment using two Schanz screws. All forces and torques were registered on-line during the reduction process. The maximum resulting force was 411 N, the maximum resulting torque 74 N (.) m. The highest force was observed along the shaft axis with 396 N for distraction. The maximum torque value was measured around the frontal axis, being 74 N (.) m for antecurvature. These results may assist the development of new reduction techniques and devices. (c) 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 50 条
  • [41] Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem
    Meek, RMD
    Garbuz, DS
    Masri, BA
    Greidanus, NV
    Duncan, CP
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (03): : 480 - 485
  • [42] Intraoperative Assessment of Coronal Alignment in Distal Femur Fracture Fixation: Technical Trick
    Scott, Brandon R.
    Wright, Raymond D.
    Moghadamian, Eric S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (02) : E69 - E72
  • [43] Intraoperative measurements of reverse total shoulder arthroplasty contact forces
    Farmer, Kevin W.
    Higa, Masaru
    Banks, Scott A.
    Chang, Chih-Chiang
    Struk, Aimee M.
    Wright, Thomas W.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2020, 7 (01)
  • [44] Intraoperative measurements of reverse total shoulder arthroplasty contact forces
    Kevin W. Farmer
    Masaru Higa
    Scott A. Banks
    Chih-Chiang Chang
    Aimee M. Struk
    Thomas W. Wright
    Journal of Experimental Orthopaedics, 7
  • [45] Instrumented Trial Prosthesis for Intraoperative Measurements of Joint Reaction Forces during Reverse Total Shoulder Arthroplasty
    Higa, Masaru
    Chang, Chih-Chiang
    Roche, Christopher
    Struk, Aimee M.
    Farmer, Kevin W.
    Wright, Thomas W.
    Banks, Scott A.
    SENSORS AND MATERIALS, 2018, 30 (09) : 1989 - 1996
  • [46] INTRAOPERATIVE FEMUR FRACTURES DURING TOTAL HIP-REPLACEMENT
    TAYLOR, MM
    MEYERS, MH
    HARVEY, JP
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1978, (137) : 96 - 103
  • [47] A femur fracture reduction method based on anatomy of the contralateral side
    Hu, Lei
    Zhang, Jie
    Li, Changsheng
    Wang, Yun
    Yang, Yan
    Tang, Peifu
    Fang, Liming
    Zhang, Lihai
    Du, Hailong
    Wang, Liquan
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (07) : 840 - 846
  • [48] TRAUMATIC DISLOCATION OF THE HIP WITH IPSILATERAL FRACTURE OF THE FEMUR - A METHOD OF REDUCTION
    CARLSEN, AW
    LIND, J
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1991, 22 (01): : 68 - 69
  • [49] Multimodal intraoperative monitoring during reduction of spine burst fracture and dislocation prevents neurologic injury
    Yu, Tong
    Wang, Yao
    Zhang, Xi-Wen
    Jiang, Zhen-De
    Zhu, Xiu-Jie
    Jiang, Qi-Yao
    Zhao, Jian-Wu
    MEDICINE, 2018, 97 (10)
  • [50] Force-torque intraoperative measurements for femoral shaft fracture reduction (vol 21, pg 37, 2016)
    Zhu, Q.
    Liang, B.
    Wang, X.
    Sun, X.
    Wang, L.
    Computer Assisted Surgery, 2016, 21 : CP30 - CP30