Forces and torques during fracture reduction:: Intraoperative measurements in the femur

被引:49
|
作者
Gösling, T
Westphal, R
Faülstich, J
Sommer, K
Wahl, F
Krettek, C
Hufner, T
机构
[1] Hannover Med Sch, Trauma Dept, D-30625 Hannover, Germany
[2] Tech Univ Carolo Wilhelmina Braunschweig, Inst Robot & Proc Control, D-38106 Braunschweig, Germany
关键词
fracture; reduction; femur; torque; force;
D O I
10.1002/jor.20045
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Reduction is a crucial step in fracture treatment. We determined intraoperative peak forces and torques during fracture reduction in seven patients with eight fractures of the femoral shaft. All fractures were temporarily stabilized by external fixation. Force and torque measurements were performed during the subsequent intramedullary nailing procedure. A three-dimensional load cell was attached to the distal femur fragment using two Schanz screws. All forces and torques were registered on-line during the reduction process. The maximum resulting force was 411 N, the maximum resulting torque 74 N (.) m. The highest force was observed along the shaft axis with 396 N for distraction. The maximum torque value was measured around the frontal axis, being 74 N (.) m for antecurvature. These results may assist the development of new reduction techniques and devices. (c) 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:333 / 338
页数:6
相关论文
共 50 条
  • [1] Reduction of fracture of shaft of femur
    Hanly, GJ
    BRITISH MEDICAL JOURNAL, 1939, 2 : 1088 - 1088
  • [2] Force-torque intraoperative measurements for femoral shaft fracture reduction
    Zhu, Qing
    Liang, Bin
    Wang, Xingsong
    Sun, Xiaogang
    Wang, Liming
    Computer Assisted Surgery, 2016, 21 : 37 - 45
  • [3] Intraoperative periprosthetic femur fracture during bipolar hemiarthroplasty for displaced femoral neck fractures
    Choon Chiet Hong
    Nazrul Nashi
    Jiong Hao Tan
    Ruben Manohara
    Wei Ting Lee
    Diarmuid Paul Murphy
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 1189 - 1198
  • [4] Intraoperative periprosthetic femur fracture during bipolar hemiarthroplasty for displaced femoral neck fractures
    Hong, Choon Chiet
    Nashi, Nazrul
    Tan, Jiong Hao
    Manohara, Ruben
    Lee, Wei Ting
    Murphy, Diarmuid Paul
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (09) : 1189 - 1198
  • [5] Optimizing intraoperative imaging during proximal femur fracture fixation - a performance improvement program
    Rikli, D.
    Seibert, F.
    Benninger, E.
    Platz, A.
    Tomazevic, M.
    Goldhahn, S.
    Joeris, A.
    Cunningham, M.
    BRITISH JOURNAL OF SURGERY, 2017, 104 : 19 - 19
  • [6] Intraoperative Periprostehtic Femur Fracture - When is the Cerclage Enough?
    Hardt, Sebastian
    Giebel, Gregor
    Hube, Robert
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2024, 162 (04): : 349 - 359
  • [7] OPEN REDUCTION OF FRACTURE OF THE NECK OF THE FEMUR
    MORITA
    TUTUMI
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1960, 42 (03): : 543 - 543
  • [8] Development of a femur fracture reduction robot
    Warisawa, S
    Ishizuka, T
    Mitsuishi, M
    Sugano, N
    Yonenobu, K
    Nakazawa, T
    2004 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1- 5, PROCEEDINGS, 2004, : 3999 - 4004
  • [9] FORCES AND TORQUES DURING SPORTS ACTIVITIES WITH HIGH ACCELERATION
    DENOTH, J
    GRUBER, K
    RUDER, H
    KEPPLER, M
    JOURNAL OF BIOMECHANICS, 1985, 18 (07) : 552 - 552
  • [10] Intraoperative Periprosthetic Femur Fracture: A Biomechanical Analysis of Cerclage Fixation
    Frisch, Nicholas B.
    Charters, Michael A.
    Sikora-Klak, Jakub
    Banglmaier, Richard F.
    Oravec, Daniel J.
    Silverton, Craig D.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (08): : 1449 - 1457