Evaluation of the Hydrodynamic Performance of High-Frequency Sonoreactors Using PIV

被引:1
|
作者
Rivadeneyra-Romero, Gabriela [1 ,2 ]
Gutierrez-Torres, Claudia [1 ]
Gonzalez-Neria, Israel [3 ]
Alonzo-Garcia, Alejandro [4 ]
Yanez-Varela, Juan A. [3 ]
Mendoza-Escamilla, Victor [3 ]
Jimenez-Bernal, Jose A. [1 ]
Martinez-Delgadillo, Sergio A. [3 ]
机构
[1] Inst Politecn Nacl, SEPI ESIME Zacatenco, Mexico City 07738, DF, Mexico
[2] Univ Istmo, Oaxaca 70760, Oaxaca, Mexico
[3] Univ Autonoma Metropolitana Azcapotzalco, Div Ciencias Basicas & Ingn, Mexico City 02200, DF, Mexico
[4] CONACyT, Ctr Ingn & Desarrollo Ind, Ciudad del Carmen 24150, Campeche, Mexico
关键词
FLUID-FLOW; TRANSFER INTENSIFICATION; CAVITATIONAL ACTIVITY; HEAT-TRANSFER; ULTRASOUND; POWER; CFD; ENERGY; VELOCITY;
D O I
10.1021/acs.iecr.0c02702
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this work, the influence on the flow behavior produced by different operating conditions (varying power dissipation of 300 and 450 W, that is, 60 and 90% of maximum power and two frequencies of 500 and 1000 kHz) in sonoreactors was experimentally characterized by 2D-PIV (particle image velocimetry) technique. Based on the experimental measurements performed at the different operational conditions of power and frequency, the velocity fields produced by the interaction of twelve piezoelectrics operating at the same time were obtained. The vorticity and Reynolds distribution maps at different operating conditions were also obtained. The axial circulation time (t(ax)) was experimentally measured showing a significant decrease for higher power and frequency levels. The fastest t(ax) obtained was 5.79 s. Energy efficiency and the specific power consumption (P/V) were also estimated at both ultrasonic frequencies and powers. Energy efficiency showed a strong dependence on specific power consumption. Distinctive recirculation patterns defined by two large lateral loops interacting with other less energetic were identified. A dimensionless number (N-QP(z)) that measures the ratio between the axial flow rate (Q(ax(z))) and ultrasonic power (P-us) is proposed. The experimental PIV measurements showed that velocity components aligned to the acoustic streaming, prevailed over perpendicular components. Highest velocities were reached at 1000 kHz and increased with ultrasonic power. At this frequency, the highest efficient axial circulation was reached and the shorter mixing times theta(95) and t(ax) were obtained.
引用
收藏
页码:18211 / 18221
页数:11
相关论文
共 50 条
  • [41] EVALUATION OF DYNAMIC FACTORS OF HIGH-FREQUENCY GALVANOMETERS
    REZNIK, MB
    MEASUREMENT TECHNIQUES-USSR, 1969, (05): : 688 - &
  • [42] DESIGN AND PERFORMANCE OF A HIGH-FREQUENCY ELECTROSTATIC SPEAKER
    BOBB, L
    GOLDMAN, RB
    ROOP, RW
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1955, 27 (01): : 211 - 211
  • [43] HIGH-FREQUENCY DESIGN AND PERFORMANCE OF TUBULAR CAPACITORS
    MURPHY, AT
    YOUNG, FJ
    IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1993, 16 (02): : 228 - 237
  • [44] DESIGN AND PERFORMANCE OF A HIGH-FREQUENCY ELECTROSTATIC SPEAKER
    BOBB, L
    GOLDMAN, RB
    ROOP, RW
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1955, 27 (06): : 1128 - 1133
  • [45] High-Frequency Ultrasound for Evaluation of Intimal Thickness
    Mohler, Emile R., III
    Sibley, Alexandra A.
    Schultz, Susan M.
    Zhang, Lifeng
    Sehgal, Chandra M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (10) : 1129 - 1133
  • [46] EXPERIMENTAL EVALUATION OF HIGH-FREQUENCY JET VENTILATION
    GROEGER, JS
    CARLON, GC
    HOWLAND, WS
    RAY, C
    MIODOWNIK, S
    CRITICAL CARE MEDICINE, 1984, 12 (09) : 747 - 749
  • [48] EVALUATION OF MYOCARDIAL MICROVASCULATURE BY HIGH-FREQUENCY ULTRASOUND
    CHANDRARATNA, PAN
    KHAN, M
    CHANDRASOMA, P
    JONES, JP
    GALLET, J
    CIRCULATION, 1992, 86 (04) : 575 - 575
  • [49] CIRCULATORY PERFORMANCE NEONATES ON HIGH-FREQUENCY OSCILLATION
    NELLE, M
    ZILOW, EP
    LINDERKAMP, O
    PEDIATRIC RESEARCH, 1994, 36 (01) : A32 - A32
  • [50] High-frequency performance of subthreshold SOI MESFETs
    Yang, JM
    Spann, J
    Anderson, R
    Thornton, T
    IEEE ELECTRON DEVICE LETTERS, 2004, 25 (09) : 652 - 654