Evaluation neointimal coverage in patients with coronary artery aneurysm formation after drug-eluting stent implantation by optical coherence tomography

被引:9
|
作者
Tian Feng [1 ]
Chen Yundai [1 ]
Liu Hongbin [1 ]
Chen Lian [1 ]
Sun Zhijun [1 ]
Guo Jun [1 ]
Jin Qinhua [1 ]
Zhang Tao [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Cardiol, Beijing 100853, Peoples R China
来源
关键词
Drug-eluting stent; Coronary artery aneurysms; Optical coherence tomography; TERM-FOLLOW-UP; THROMBOSIS; MALAPPOSITION; ANGIOPLASTY; APPOSITION; PREDICTORS; RISK;
D O I
10.1007/s10554-013-0282-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The neointimal coverage in patients with coronary artery aneurysms (CAA) formation after drug eluting stent (DES) implantation is not clear. Total of 175 patients who had been implanted DES were identified. Patients were divided into the CAA group (n = 31) and non-CAA group (n = 144) based on the results of the coronary angiography. The cardiac events including angina and acute myocardial infarction were noted, in addition, the neointimal thickness and the frequence of strut malapposition and strut uncoverage were noted. A greater proportion of incomplete neointimal coverage (17.17 vs. 1.9 %, P < 0.001) and malapposition struts (18.2 vs. 1.38%, P < 0.001) were observed in the CAA group. 8 patients in CAA group underwent OCT examination twice in the period of follow-up. The proportion of incomplete neointimal coverage increased significantly as compared the second OCT results with the first examination (18.45 vs. 2.66 %, P < 0.001). Hyperplasia neointimal desquamated from struts and acquired struts incomplete neointimal coverage were detected. Patients with CAA had a higher frequency of cardiac events including angina pectoris (25.81 vs. 6.25 %, P = 0.001) and acute myocardial infarction (9.68 vs. 0.13 %, P = 0.002) and thrombosis (16.13 vs. 0.69 %, P < 0.001). The longitudinal length of CAA in cardiac event group was significantly longer than no cardiac event group (20.0 +/- A 9.07 vs. 12.05 +/- A 5.38 mm, P = 0.005). CAA formation after DES implantation frequently associated with cardiac events as a result of stent malapposition and incomplete neointimal coverage. Acquired incomplete neointimal coverage associated with CAA formation.
引用
收藏
页码:1677 / 1683
页数:7
相关论文
共 50 条
  • [41] Clinical outcomes of patients with coronary artery aneurysm after the first generation drug-eluting stent implantation
    Joo, Hyung Joon
    Yu, Cheol Woong
    Choi, RakKyeong
    Park, Jinsik
    Lee, Hyun Jong
    Kim, Je Sang
    Choi, Young Jin
    Park, Jae Hyoung
    Hong, Soon Jun
    Lim, Do Sun
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (03) : E235 - E245
  • [42] Optical coherence tomography surveillance following drug-eluting stent implantation
    Koppara, T.
    Virmani, R.
    Joner, M.
    [J]. MINERVA CARDIOANGIOLOGICA, 2015, 63 (01): : 59 - 74
  • [43] Multiple coronary micro-aneurysm formation after drug-eluting stent implantation
    Christou, Apostolos H.
    Papadakis, Emmanouil C.
    Nikolaou, Nikolaos I.
    Antonatos, Dionysios G.
    Anadiotis, Athanasios V.
    Patsilinakos, Sotirios P.
    [J]. HELLENIC JOURNAL OF CARDIOLOGY, 2016, 57 (03) : 191 - 193
  • [44] Relationship between Stent Malapposition and Incomplete Neointimal Coverage after Drug-Eluting Stent Implantation
    Kim, Byeong-Keuk
    Hong, Myeong-Ki
    Shin, Dong-Ho
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2012, 25 (03) : 270 - 277
  • [45] Coronary Artery Aneurysms After Drug-Eluting Stent Implantation
    Aoki, Jiro
    Kirtane, Ajay
    Leon, Martin B.
    Dangas, George
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (01) : 14 - 21
  • [46] Optical Coherence Tomographic Observation of Morphological Features of Neointimal Tissue after Drug-Eluting Stent Implantation
    Lee, Seung-Yul
    Shin, Dong-Ho
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. YONSEI MEDICAL JOURNAL, 2014, 55 (04) : 944 - 952
  • [47] Ex vivo assessment of neointimal characteristics after drug-eluting stent implantation: Optical coherence tomography and histopathology validation study
    Imanaka, Takahiro
    Fujii, Kenichi
    Hao, Hiroyuki
    Shibuya, Masahiko
    Saita, Ten
    Kawakami, Rika
    Fukunaga, Masashi
    Kawai, Kenji
    Tamaru, Hiroto
    Miki, Kojiro
    Horimatsu, Tetsuo
    Sumiyoshi, Akinori
    Nishimura, Machiko
    Hirota, Seiichi
    Masuyama, Tohru
    Ishihara, Masaharu
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 221 : 1043 - 1047
  • [48] Impact of Procedure-Related Vessel Wall Injury on Coronary Aneurysm Formation After Drug-Eluting Stent Implantation: A Serial Optical Coherence Tomography Study
    Tahara, Satoko
    Guagliumi, Giulio
    Sirbu, Vasile
    Bezerra, Hiram G.
    Kyono, Hiroyuki
    Musumeci, Giuseppe
    Lortkipanidze, Nicolos
    Wang, Wei
    Mehanna, Emile
    Ikejima, Hideyuki
    Matiashvili, Alexander
    Pokras, Stan
    Costa, Marco A.
    [J]. CIRCULATION, 2010, 122 (21)
  • [49] Changes of the Protruded Plaque After Drug-Eluting Stent Implantation in Patients With Acute Coronary Syndrome Evaluated With Optical Coherence Tomography
    Aoki, Yuki
    Nakamura, Norihito
    Aihara, Kazuki
    Torii, Sho
    Natsumeda, Makoto
    Ohno, Yohei
    Tanaka, Shigemitsu
    Nakazawa, Gaku
    Ikari, Yuji
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B213 - B213
  • [50] Optical coherence tomography findings of very late stent thrombosis after drug-eluting stent implantation
    Young-Guk Ko
    Dong-Min Kim
    Jin Man Cho
    So Yeon Choi
    Jung Han Yoon
    Jung-Sun Kim
    Byeong-Keuk Kim
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    [J]. The International Journal of Cardiovascular Imaging, 2012, 28 : 715 - 723