Evaluation neointimal coverage in patients with coronary artery aneurysm formation after drug-eluting stent implantation by optical coherence tomography

被引:9
|
作者
Tian Feng [1 ]
Chen Yundai [1 ]
Liu Hongbin [1 ]
Chen Lian [1 ]
Sun Zhijun [1 ]
Guo Jun [1 ]
Jin Qinhua [1 ]
Zhang Tao [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Cardiol, Beijing 100853, Peoples R China
来源
关键词
Drug-eluting stent; Coronary artery aneurysms; Optical coherence tomography; TERM-FOLLOW-UP; THROMBOSIS; MALAPPOSITION; ANGIOPLASTY; APPOSITION; PREDICTORS; RISK;
D O I
10.1007/s10554-013-0282-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The neointimal coverage in patients with coronary artery aneurysms (CAA) formation after drug eluting stent (DES) implantation is not clear. Total of 175 patients who had been implanted DES were identified. Patients were divided into the CAA group (n = 31) and non-CAA group (n = 144) based on the results of the coronary angiography. The cardiac events including angina and acute myocardial infarction were noted, in addition, the neointimal thickness and the frequence of strut malapposition and strut uncoverage were noted. A greater proportion of incomplete neointimal coverage (17.17 vs. 1.9 %, P < 0.001) and malapposition struts (18.2 vs. 1.38%, P < 0.001) were observed in the CAA group. 8 patients in CAA group underwent OCT examination twice in the period of follow-up. The proportion of incomplete neointimal coverage increased significantly as compared the second OCT results with the first examination (18.45 vs. 2.66 %, P < 0.001). Hyperplasia neointimal desquamated from struts and acquired struts incomplete neointimal coverage were detected. Patients with CAA had a higher frequency of cardiac events including angina pectoris (25.81 vs. 6.25 %, P = 0.001) and acute myocardial infarction (9.68 vs. 0.13 %, P = 0.002) and thrombosis (16.13 vs. 0.69 %, P < 0.001). The longitudinal length of CAA in cardiac event group was significantly longer than no cardiac event group (20.0 +/- A 9.07 vs. 12.05 +/- A 5.38 mm, P = 0.005). CAA formation after DES implantation frequently associated with cardiac events as a result of stent malapposition and incomplete neointimal coverage. Acquired incomplete neointimal coverage associated with CAA formation.
引用
收藏
页码:1677 / 1683
页数:7
相关论文
共 50 条
  • [1] Evaluation of neointimal coverage in patients with coronary artery aneurysm formation after drug-eluting stent implantation by optical coherence tomography
    TIAN Feng
    CHEN Yun-dai
    CHEN Lian
    SUN Zhi-jun
    GUO Jun
    JIN Qin-hua
    LIU Chang-fu
    WANG Jin-da
    LIU Hong-bin
    [J]. 中华医学杂志(英文版), 2013, 126 (11) : 2092 - 2097
  • [2] Evaluation neointimal coverage in patients with coronary artery aneurysm formation after drug-eluting stent implantation by optical coherence tomography
    Tian Feng
    Chen Yundai
    Liu Hongbin
    Chen Lian
    Sun Zhijun
    Guo Jun
    Jin Qinhua
    Zhang Tao
    [J]. The International Journal of Cardiovascular Imaging, 2013, 29 : 1677 - 1683
  • [3] Evaluation of neointimal coverage in patients with coronary artery aneurysm formation after drug-eluting stent implantation by optical coherence tomography
    Tian Feng
    Chen Yun-dai
    Chen Lian
    Sun Zhi-jun
    Guo Jun
    Jin Qin-hua
    Liu Chang-fu
    Wang Jin-da
    Liu Hong-bin
    [J]. CHINESE MEDICAL JOURNAL, 2013, 126 (11) : 2092 - 2097
  • [4] Coronary artery aneurysm formation after drug-eluting stent implantation
    Levisay, Justin P.
    Roth, Ronald M.
    Schatz, Richard A.
    [J]. CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2008, 9 (04) : 284 - 287
  • [5] Prediction of late neointimal regression after drug-eluting stent implantation by optical coherence tomography
    Okura, H.
    Fukuhara, K.
    Yamada, R.
    Kume, T.
    Neishi, Y.
    Yoshida, K.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 1145 - 1145
  • [6] Dynamic neointimal pattern after drug-eluting stent implantation defined by optical coherence tomography
    Yamamoto, Erika
    Xing, Lei
    Higuma, Takumi
    Minami, Yoshiyasu
    Bryniarski, Krzysztof
    Zanchin, Thomas
    Wang, Zhao
    Aguirre, Aaron D.
    Lee, Hang
    Jang, Ik-Kyung
    [J]. CORONARY ARTERY DISEASE, 2017, 28 (07) : 557 - 563
  • [7] Longitudinal neointimal distribution after drug-eluting stent implantation: an optical coherence tomography study
    Otsuki, S.
    Brugaletta, S.
    Shiratori, Y.
    Scalone, G.
    Gomez-Monterrosas, O.
    Romero-Villafane, S.
    Freixa, X.
    Martin-Yuste, V.
    Masotti, M.
    Sabate, M.
    [J]. EUROPEAN HEART JOURNAL, 2015, 36 : 490 - 490
  • [8] Optical coherence tomography assessment of edge dissections after drug-eluting stent implantation in coronary artery
    GUO JunCHEN YundaiTIAN FengLIU HongbinCHEN LianSUN ZhijunREN YihongJIN Qinhua LIU ChangfuHAN BaoshiGAI Luyue and YANG Tingshu Department of CardiologyChinese Peoples Liberation Army General HospitalBeijing China
    [J]. 中华医学杂志(英文版), 2012, (06) : 1047 - 1050
  • [9] Optical coherence tomography assessment of edge dissections after drug-eluting stent implantation in coronary artery
    Guo Jun
    Chen Yun-dai
    Tian Feng
    Liu Hong-bin
    Chen Lian
    Sun Zhi-jun
    Ren Yi-hong
    Jin Qin-hua
    Liu Chang-fu
    Han Bao-shi
    Gai Lu-yue
    Yang Ting-shu
    [J]. CHINESE MEDICAL JOURNAL, 2012, 125 (06) : 1047 - 1050
  • [10] Can Angiographic Late Loss Predict the Neointimal Coverage Of Stent Strut On Optical Coherence Tomography After Drug-eluting Stent Implantation?
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Jang, Yangsoo
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (13) : B14 - B14