Label-free protein detection using a microfluidic Coulter-counter device

被引:32
|
作者
Rodriguez-Trujillo, Romen [1 ]
Ajine, Mohammad A. [1 ]
Orzan, Alice [1 ]
Mar, Mikkel D. [2 ]
Larsen, Flemming [1 ]
Clausen, Casper H. [1 ]
Svendsen, Winnie E. [1 ]
机构
[1] Tech Univ Denmark, Dept Micro & Nanotechnol, DK-2800 Lyngby, Denmark
[2] Tech Univ Denmark, Natl Ctr Micro & Nanofabricat, DK-2800 Lyngby, Denmark
关键词
Label-free detection; Protein; Coulter-counter; Microfluidics; Impedance; Bead-based assay; IMPEDANCE SPECTROSCOPY; FLOW CYTOMETER; SERUM;
D O I
10.1016/j.snb.2013.09.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for measuring specific protein concentrations in solutions has been developed. The technique makes use of the Coulter effect for detecting and sizing of micro-scaled objects suspended in a buffer fluid. The method is completely label-free as it is only based on the electrical readout when a suspension of microscopic beads flows over a set of electrodes in a microfluidic device. Since no electrode functionalization is needed the same device can be used in a number of different assays. Using goat-anti-rat IgG functionalized polystyrene beads we have shown proof of principle detecting rat IgG in solution. When the analyte (rat IgG) is present oligomers of beads are formed. The electrical readout of the oligomers is different compared to a zero control sample with no rat IgG. Detection of the protein has been performed in a concentration as small as 14 ng/mL. The dynamic range of the system has been demonstrated to be relatively large, ranging from 1 mu g/mL to 14 ng/mL. The microfluidic system is made from polymer and glass and very little volume of sample (<10 mu L) is needed for analysis. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:922 / 927
页数:6
相关论文
共 50 条
  • [21] PARTICLE-SIZE ANALYSIS OF BEER SOLIDS USING A COULTER-COUNTER
    MORRIS, TM
    JOURNAL OF THE INSTITUTE OF BREWING, 1984, 90 (03) : 162 - 166
  • [22] Label-free Hematological Assessment of Neutropenia using a Microfluidic Device and Deep-UV Microscopy
    Ojaghi, Ashkan
    Gorti, Viswanath
    Robles, Francisco E.
    OPTICAL DIAGNOSTICS AND SENSING XXII: TOWARD POINT-OF-CARE DIAGNOSTICS, 2022, 11968
  • [23] USE OF THE COULTER-COUNTER MODEL ZM FOR PARTICLE-DETECTION IN PARENTERAL LIQUIDS
    SUGRUE, S
    INTERNATIONAL CONFERENCE ON LIQUID BORNE PARTICLE INSPECTION AND METROLOGY, 1987, : 412 - 421
  • [24] Terahertz Imaging for Label-free Protein Detection
    Ogawa, Y.
    Hayashi, S.
    Yoshida, H.
    Otani, C.
    Kawase, K.
    2009 34TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, VOLS 1 AND 2, 2009, : 352 - +
  • [25] Label-free, capacitive immunosensor for protein detection
    Gul, Ozgur
    Heves, Emre
    Kaynak, Mehmet
    Basaga, Huveyda
    Gurbuz, Yasar
    2006 IEEE SENSORS, VOLS 1-3, 2006, : 600 - +
  • [26] Label-free detection methods for protein microarrays
    Yu, Xiaobo
    Xu, Danke
    Cheng, Quan
    PROTEOMICS, 2006, 6 (20) : 5493 - 5503
  • [27] DETERMINATION OF THE CLONING EFFICIENCY OF HUMAN RHABDOMYOSARCOMA CELLS USING A COULTER-COUNTER
    HAZELTON, BJ
    TORRANCE, PM
    HOUGHTON, PJ
    PROCEEDINGS OF THE AMERICAN ASSOCIATION FOR CANCER RESEARCH, 1983, 24 (MAR): : 312 - 312
  • [28] AN EASY QUANTITATIVE CYTO-TOXICITY ASSAY USING A COULTER-COUNTER
    IWAMOTO, M
    SEIKAGAKU, 1982, 54 (10): : 1193 - 1196
  • [29] Single cell manipulation, analytics, and label-free protein detection in microfluidic devices for systems nanobiology
    Hellmich, W
    Pelargus, C
    Leffhalm, K
    Ros, A
    Anselmetti, D
    ELECTROPHORESIS, 2005, 26 (19) : 3689 - 3696
  • [30] Label-free microfluidic sorting of microparticles
    Zhou, Jian
    Mukherjee, Prithviraj
    Gao, Hua
    Luan, Qiyue
    Papautsky, Ian
    APL BIOENGINEERING, 2019, 3 (04):