A new technique for Nd:YAG laser posterior capsulotomy

被引:7
|
作者
Min, Jung Kee [1 ]
An, Jae Hwan [1 ]
Yim, Jin Ho [2 ]
机构
[1] Univ Ulsan, Coll Med, Ulsan Univ Hosp, Dept Ophthalmol, Ulsan 682714, South Korea
[2] Samsung Eye Clin, Cheongju 361270, Chungbuk, South Korea
关键词
cataract; intraocular lens damage; posterior capsular opacification; vitreous strand; YAG laser capsulotomy; ND-YAG CAPSULOTOMY; RETINAL-DETACHMENT; CATARACT-SURGERY; INTRAOCULAR LENSES; TERM CHANGES; FOLLOW-UP; NEODYMIUM; OPACIFICATION; MORPHOLOGY; COMPLICATIONS;
D O I
10.3980/j.issn.2222-3959.2014.02.28
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To investigate the effects of a new opening pattern in neodymium:yttrium -aluminum -garnet (Nd:YAG) laser posterior capsulotomy on visual function. METHODS: This technique was conducted along a circular pattern. The energy ranged between 0.8 and 1.2 mJ/pulse was consumed and mean total energy levels were 74 +/- 21 mJ (mean standard deviation: SD, from 40 to 167) and laser shots aimed at 150 mu M away behind a datum point and went along an imaginary line which extends 0.5 mm inside from optic margin and into the circular en bloc pattern. Vitreous stands were attached with fragment and then they were cut off by the laser after circular application. The circular fragment was completely separated from vitreous, and then this fragment was quickly sunk in intravitreal space. RESULTS: The follow-up period ranges from at least a week to 40mo, making 15.8mo on average. The procedural outcome showed 96% (74 eyes out of the 77 eyes) enhancement in patients' visual acuity. Cystoid macular edema or retinal detachment was not observed in any of the patients during follow-up periods. CONCLUSION: This new technique is expected to improve the weaknesses that the conventional procedures have by adding the process to cut off vitreous stands attached with the fragment by the laser to the circular application.
引用
收藏
页码:345 / 349
页数:5
相关论文
共 50 条
  • [21] Use of Nd:YAG laser capsulotomy
    Aslam, TM
    Devlin, H
    Dhillon, B
    [J]. SURVEY OF OPHTHALMOLOGY, 2003, 48 (06) : 594 - 612
  • [22] Use of Nd:YAG laser capsulotomy
    Schubert, H
    [J]. SURVEY OF OPHTHALMOLOGY, 2004, 49 (03) : 376 - 377
  • [23] Incidence of retinal detachment (RD) after neodymium:: YAG laser posterior capsulotomy (Nd:YAG)
    Jahn, CE
    Kremer, G
    Jahn, AH
    Kron, M
    Richter, J
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U135 - U135
  • [24] VISUAL OUTCOME OF Nd-YAG LASER CAPSULOTOMY IN POSTERIOR CAPSULE OPACIFICATION
    Sirisha, Gantela
    Chowdary, Nallabantu Lakshmi
    [J]. JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (29): : 1479 - 1482
  • [25] Nd:YAG laser posterior capsulotomy after pediatric and adult cataract surgery
    Cinal, Adnan
    Demirok, Ahmet
    Yasar, Tekin
    Yazicioglu, Atilla
    Yener, H. Ibrahim
    Kilic, Adil
    [J]. ANNALS OF OPHTHALMOLOGY, 2007, 39 (04) : 321 - 326
  • [26] BILATERAL MACULAR HOLES AFTER ND-YAG LASER POSTERIOR CAPSULOTOMY
    BLACHARSKI, PA
    NEWSOME, DA
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1988, 105 (04) : 417 - 418
  • [27] Posterior capsule opacification and problems of Nd:YAG laser capsulotomy in retinitis pigmentosa
    Auffarth, GU
    Nimsgern, C
    Tetz, MR
    Krastel, H
    Volcker, HE
    [J]. OPHTHALMOLOGE, 1997, 94 (11): : 791 - 795
  • [28] The effect of Nd:YAG laser posterior capsulotomy on ocular wave front aberrations
    Levy, Jaime
    Lifshitz, Tova
    Klemperer, Itamar
    Knyazer, Boris
    Ashkenazy, Zach
    Kratz, Assaf
    Belfair, Nadav
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2009, 44 (05): : 529 - 533
  • [29] EVALUATION OF VISUAL FUNCTION FOLLOWING ND-YAG LASER POSTERIOR CAPSULOTOMY
    MAGNO, BV
    DATILES, MB
    LASA, MSM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S812 - S812
  • [30] Pseudophakic retinal detachment in eyes with and without Nd:Yag laser posterior capsulotomy
    Ranta, P
    Kivela, T
    [J]. VISION RESEARCH, 1996, 36 : 3117 - 3117