Neuroendocrine and haemodynamic changes in single-lead atrial pacing and dual-chamber pacing modes

被引:2
|
作者
Zhang, Ying-ying [1 ,2 ]
Wu, Dong-yan [2 ]
Fu, Nai-kuan [2 ]
Lu, Feng-min [2 ]
Xu, Jing [2 ]
机构
[1] Tianjin Med Univ, Grad Sch, Tianjin, Peoples R China
[2] Tianjin Chest Hosp, Dept Cardiol, Tianjin, Peoples R China
关键词
Sick sinus syndrome; single-lead atrial pacing; AAI; dual-chamber pacing; DDD; aortic flow velocity-time integral; interventricular mechanical delay; CARDIAC RESYNCHRONIZATION THERAPY; LEFT-VENTRICULAR DYSSYNCHRONY; NATRIURETIC PEPTIDE LEVELS; SICK SINUS SYNDROME; HEART-FAILURE; PLASMA-ALDOSTERONE; FIBRILLATION; ACTIVATION; ASYNCHRONY; PACEMAKER;
D O I
10.1177/0300060513489798
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives: Neuroendocrine and haemodynamic changes were compared between single-lead atrial (AAI) or dual-chamber (DDD) pacing modes in patients with sick sinus syndrome, in a crossover study. Methods: Inpatients scheduled for their first pacemaker implantation were screened for the following inclusion criteria: sick sinus syndrome; intact atrioventricular conduction; normal QRS interval. All study patients were implanted with a dual-chamber pacemaker, programmed for AAI or DDD pacing mode. Patients were allocated randomly to AAI followed by DDD pacing or to DDD followed by AAI pacing, each mode being applied for 72h. Echocardiographic, electrocardiographic and neuroendocrine parameters were tested at the end of each pacing mode. Results: From 152 inpatients screened for inclusion, 28 were selected for treatment. Plasma levels of atrial natriuretic peptide (ANP), endothelin, aldosterone and angiotension II were significantly lower, and aortic flow velocity-time integral was significantly higher, in AAI mode than in DDD mode. Aortic pre-ejection interval, interventricular mechanical delay and QRS duration were significantly higher in DDD than in AAI mode. Conclusions: In patients with sick sinus syndrome, DDD pacing mode can induce neuroendocrine system activation, and left ventricular dysfunction and dyssynchrony. These findings discourage the routine use of DDD pacing in patients with sick sinus syndrome.
引用
下载
收藏
页码:1057 / 1066
页数:10
相关论文
共 50 条
  • [41] CLINICAL-RESULTS OF DUAL-CHAMBER PACING
    PARSONNET, V
    WERRES, R
    ATHERLEY, T
    BALBACH, C
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1983, 6 (02): : 312 - 312
  • [42] DUAL-CHAMBER PACING IN HYPERTENSIVE HYPERTROPHIC CARDIOMYOPATHY
    PAK, P
    MAUGHAN, L
    KASS, DA
    CIRCULATION, 1995, 92 (08) : 3756 - 3756
  • [43] DUAL-CHAMBER PACING IN THE CARDIOMYOPATHY OF PRIMARY AMYLOIDOSIS
    CLUGSTON, RA
    DAVIS, MJE
    MEDICAL JOURNAL OF AUSTRALIA, 1988, 148 (05) : 256 - &
  • [44] Dual-Chamber Leadless Pacing: The Future is Wireless
    Tang, Jonathan E.
    Awad, Hamdy
    Essandoh, Michael K.
    Iyer, Manoj H.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 38 (01) : 1 - 3
  • [45] Dual-chamber pacing in a patient with hypertrophic cardiomyopathy
    Nishimura, RA
    Symanski, JD
    Hurrell, DG
    CIRCULATION, 1997, 96 (05) : 1701 - 1701
  • [46] DECIDING WHO NEEDS DUAL-CHAMBER PACING
    JOSEPH, S
    BRITISH MEDICAL JOURNAL, 1993, 307 (6903): : 567 - 567
  • [47] OUTCOME OF DUAL-CHAMBER PACING FOR THE PACEMAKER SYNDROME
    NISHIMURA, RA
    GERSH, BJ
    HOLMES, DR
    VLIETSTRA, RE
    BROADBENT, JC
    MAYO CLINIC PROCEEDINGS, 1983, 58 (07) : 452 - 456
  • [48] Wide complex tachycardia and dual-chamber pacing
    Kantharia, BK
    HEART RHYTHM, 2005, 2 (09) : 1013 - 1014
  • [49] NEW DUAL-CHAMBER PACING MODES TO MINIMIZE RIGHT VENTRICULAR PACING ARE EFFECTIVE AND MAY IMPROVE CLINICAL OUTCOMES
    Durao, D. L.
    Martins, V.
    Alves, M.
    Cabanelas, N.
    Francisco, A.
    Loureiro, J.
    Pitta, M.
    Silva, G.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 : S78 - S78
  • [50] SINGLE-LEAD ATRIAL SYNCHRONOUS VENTRICULAR PACING - A DREAM COME TRUE
    ANTONIOLI, GE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (09): : 1531 - 1547