Translumbar repair of a type II endoleak associated with an aorta-to-left renal vein fistula after aortic stent-graft placement

被引:6
|
作者
Resnick, S
Rome, V
Eskandari, M
机构
[1] Northwestern Mem Hosp, Dept Radiol, Chicago, IL 60611 USA
[2] Univ Illinois, Coll Med, Chicago, IL USA
关键词
D O I
10.1097/01.RVI.0000195320.08434.D9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An abdominal aortic aneurysm (AAA) is a serious medical condition with significant associated morbidity and mortality. Endograft repair of AAAs is a therapy in evolution, but offers promise as a minimally invasive treatment option. Persistent sac pressurization via endoleaks has limited wider application of stent-grafting technology. The present report describes a case of an AAA with rupture into a retroaortic left renal vein that was treated acutely with aortic stent-graft repair. Continued aneurysm enlargement and a large type II endoleak drained by an arteriovenous fistula were subsequently treated via a translumbar approach.
引用
收藏
页码:557 / 561
页数:5
相关论文
共 50 条
  • [31] Effects of in situ fenestration stent-graft of left subclavian artery on the hemodynamics after thoracic endovascular aortic repair
    Qiao, Yonghui
    Mao, Le
    Ding, Ying
    Fan, Jianren
    Luo, Kun
    Zhu, Ting
    [J]. VASCULAR, 2019, 27 (04) : 369 - 377
  • [32] The Effect of Abdominal Aortic Aneurysm Size on Type II Endoleak and Sac Regression Following Endovascular Stent Graft Repair
    Hsu, Harold W.
    Dunlavy, Paul
    Franko, Jan
    Chew, David K.
    [J]. JOURNAL OF VASCULAR SURGERY, 2015, 62 (03) : 820 - 820
  • [33] Type II Endoleak After Endovascular Aortic Aneurysm Repair Using the Endurant Stent Graft System for Abdominal Aortic Aneurysm with Occluded Inferior Mesenteric Artery
    Gentsu, Tomoyuki
    Okada, Takuya
    Yamaguchi, Masato
    Horinouchi, Hiroki
    Katayama, Naoto
    Ueshima, Eisuke
    Koide, Yutaka
    Sofue, Keitaro
    Gotake, Yasuko
    Nomura, Yoshikatsu
    Tanaka, Hiroshi
    Okita, Yutaka
    Sugimoto, Koji
    Murakami, Takamichi
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2019, 42 (04) : 505 - 512
  • [34] Type II Endoleak After Endovascular Aortic Aneurysm Repair Using the Endurant Stent Graft System for Abdominal Aortic Aneurysm with Occluded Inferior Mesenteric Artery
    Tomoyuki Gentsu
    Takuya Okada
    Masato Yamaguchi
    Hiroki Horinouchi
    Naoto Katayama
    Eisuke Ueshima
    Yutaka Koide
    Keitaro Sofue
    Yasuko Gotake
    Yoshikatsu Nomura
    Hiroshi Tanaka
    Yutaka Okita
    Koji Sugimoto
    Takamichi Murakami
    [J]. CardioVascular and Interventional Radiology, 2019, 42 : 505 - 512
  • [35] Type II endoleak after endoluminal repair of thoracic aortic aneurysm associated with native coarctation
    Maitriasa, Pierre
    Mage, Adriane
    Belhomme, Denis
    Reix, Thierry
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (02) : 304 - 306
  • [36] Metabolic syndrome is associated with type II endoleak after endovascular abdominal aortic aneurysm repair
    Hall, Michael R.
    Protack, Clinton D.
    Assi, Roland
    Williams, Willis T.
    Wong, Daniel J.
    Lu, Daniel
    Muhs, Bart E.
    Dardik, Alan
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 59 (04) : 938 - 943
  • [37] A meta-analysis of translumbar embolization versus transarterial embolization for type II endoleak after endovascular repair of abdominal aortic aneurysm
    Guo, Qiang
    Zhao, Jichun
    Ma, Yukui
    Huang, Bin
    Yuan, Ding
    Yang, Yi
    Du, Xiaojiong
    [J]. JOURNAL OF VASCULAR SURGERY, 2020, 71 (03) : 1029 - +
  • [38] Association Between Extent of Stent-Graft Coverage and Thoracic Aortic Remodeling After Endovascular Repair of Type B Aortic Dissection
    Xue, Yan
    Ge, Yangyang
    Ge, Xiaohu
    Miao, Jianhang
    Fan, Weidong
    Rong, Dan
    Liu, Feng
    Liu, Xiaoping
    Guo, Wei
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (02) : 211 - 220
  • [39] Late distal perigraft endoleak after endovascular repair of an abdominal aortic aneurysm due to cranial migration of the iliac branch of a modular stent-graft
    Maleux, G
    Nevelsteen, A
    Stockx, L
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (02): : 156 - 157
  • [40] Factors Related to Late False Lumen Enlargement after Thoracic Stent-Graft Placement for Type B Aortic Dissection
    Gasparetto, Alessandro
    Park, Kwang Bo
    Sabri, Saher S.
    Park, Auh Whan
    Matsumoto, Alan H.
    Angle, John Fritz
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (01) : 44 - 49