A comparison of intrapartum automated fetal electrocardiography and conventional cardiotocography -: a randomised controlled study

被引:111
|
作者
Ojala, K
Vääräsmäki, M
Mäkikallio, K
Valkama, M
Tekay, A
机构
[1] Oulu Univ Hosp, Dept Pediat, Oulu, Finland
[2] Oulu Univ Hosp, Dept Obstet & Gynaecol, Oulu, Finland
关键词
cardiotocography; intrapartum monitoring; neonatal acidemia; ST analysis;
D O I
10.1111/j.1471-0528.2006.00886.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
To examine whether intrapartum monitoring by means of automatic ST analysis (STAN) of fetal electrocardiography could reduce the rate of neonatal acidemia and the rate of operative intervention during labour, compared with monitoring by means of cardiotocography (CTG). Randomised controlled trial. Labour ward in tertiary-level university hospital. A total of 1483 women in active labour with singleton term fetus in cephalic presentation. Women were randomly assigned to be monitored either by STAN or by CTG. Fetal blood sampling (FBS) was optional in both groups. Neonatal acidemia (umbilical artery pH < 7.10), neonatal metabolic acidosis (umbilical artery pH < 7.05 and base excess <-12 mmol/l) and operative interventions: caesarean section rate, vacuum outlet (VO) rate and FBS rate. There were no statistically significant differences between the STAN group and CTG group in the incidence of neonatal acidemia (5.8 versus 4.7%) or metabolic acidosis (1.7 versus 0.7%). The caesarean section rate (6.4 versus 4.7%) and the VO rate (9.5 versus 10.7%) were also similar in the STAN and CTG groups. The incidence of FBS was lower (P < 0.001) in the STAN group (7.0%) than in the CTG group (15.6%). Intrapartum fetal monitoring by means of automatic STAN did not improve the neonatal outcome or decrease the caesarean section rate. However, the need for FBS during labour was lower in the STAN group.
引用
收藏
页码:419 / 423
页数:5
相关论文
共 50 条
  • [21] COMPARATIVE STUDY TO DETERMINE THE RELIABILITY AND ACCURACY OF THE FETAL LITE ELECTRONIC FETAL MONITOR WHEN COMPARED WITH CONVENTIONAL CARDIOTOCOGRAPHY
    Subramanian, B. K.
    Kaulgud, S.
    Joshi, V. R.
    Godbole, Girish
    Bahulikar, Madhavi
    2018 10TH INTERNATIONAL CONFERENCE ON COMMUNICATION SYSTEMS & NETWORKS (COMSNETS), 2018, : 671 - 676
  • [22] Sensitivity and specificity of intrapartum computerised FIGO criteria for cardiotocography and fetal scalp pH during labour: multicentre, observational study
    Schiermeier, S.
    von Steinburg, S. Pildner
    Thieme, A.
    Reinhard, J.
    Daumer, M.
    Scholz, M.
    Hatzmann, W.
    Schneider, K. T. M.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2008, 115 (12) : 1557 - 1563
  • [23] Predicting Intrapartum Fetal Compromise at Term Using the Cerebroplacental Ratio and Placental Growth Factor (PROMISE) Study: A Randomised Controlled Trial
    Sherrell, H.
    Clifton, V.
    Kumar, S.
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2019, 59 : 104 - 104
  • [24] Randomised controlled trial of cardiotocography versus Doppler auscultation of fetal heart at admission in labour in low risk obstetric population
    Mires, G
    Williams, F
    Howie, P
    BRITISH MEDICAL JOURNAL, 2001, 322 (7300): : 1457 - 1460
  • [25] IMproving the practice of intrapartum electronic fetal heart rate MOnitoring with cardiotocography for safer childbirth (the IMMO programme): protocol for a qualitative study
    Lame, Guillaume
    Liberati, Elisa
    Burt, Jenni
    Draycott, Tim
    Winter, Cathy
    Ward, James
    Dixon-Woods, Mary
    BMJ OPEN, 2019, 9 (06):
  • [26] Women's satisfaction with intrapartum fetal surveillance: A mixed-method study within the STan Australian randomised controlled trial (START)
    Benton, Madeleine
    Salter, Amy
    Wilkinson, Chris
    Simpson, Bronni
    Turnbull, Deborah
    MIDWIFERY, 2025, 140
  • [27] A cost-effectiveness analysis of the intrapartum fetal pulse oximetry multicentre randomised controlled trial (the FOREMOST trial)
    East, C. E.
    Gascoigne, M. B.
    Doran, C. M.
    Brennecke, S. P.
    King, J. F.
    Colditz, P. B.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2006, 113 (09) : 1080 - 1087
  • [28] Comparison of the Use of Conventional and Prewired Electrodes for Electrocardiography in an Emergency Setting: The Spaghetti Study
    Lapostolle, Frederic
    Petrovic, Tomislav
    Bernot, Bruno
    Ballorin, Sophie
    Bossard, Gwenaelle
    Julien, Audrey
    Moisset, Denis
    Adnet, Frederic
    ANNALS OF EMERGENCY MEDICINE, 2011, 57 (04) : 357 - 361
  • [29] Predicting intrapartum fetal compromise at term using the cerebroplacental ratio and placental growth factor levels (PROMISE) study: randomised controlled trial protocol
    Sherrell, Helen
    Clifton, Vicky
    Kumar, Sailesh
    BMJ OPEN, 2018, 8 (08):
  • [30] The addition of fetal scalp blood lactate measurement as an adjunct to cardiotocography to reduce caesarean sections during labour: The Flamingo randomised controlled trial
    East, Christine E.
    Davey, Mary-Ann
    Kamlin, C. Omar F.
    Davis, Peter G.
    Sheehan, Penelope M.
    Kane, Stefan C.
    Brennecke, Shaun P.
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2021, 61 (05): : 684 - 692