UHF Sensor Array for Partial Discharge Location in Transformers

被引:0
|
作者
Sinaga, H. H. [1 ]
Phung, B. T. [1 ]
Blackburn, T. R. [1 ]
机构
[1] Univ New S Wales, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
关键词
Partial discharge; Ultra high frequency; Localization; Time difference of arrival (TDOA);
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The application of the ultra-high frequency (UHF) partial discharge (PD) detection method has proven effective in GIS. This method is now also being applied to detect PDs in oil-filled power transformers. In this paper, the localization of the PD source in transformer is discussed. This is achieved by applying an array of four sensors to capture the PD signals at the same time. To determine the PD location, two methods (first peak and cross-correlation) are used to determine the difference in time of arrival between sensor signals and followed by numerical triangulation. The sensor positions and array size influence the PD waveform patterns captured, and thus the accuracy of the PD localization. Experimental results and analysis indicate the first peak method yields better location accuracy than the cross correlation method. However, the traditional external acoustic detection method performs better than the UHF detection method under the same test configurations.
引用
收藏
页码:979 / 982
页数:4
相关论文
共 50 条
  • [41] Optimisation of a Sensor for Onsite Detection of Partial Discharges in Power Transformers by the UHF Method
    Lopez-Roldan, J.
    Tang, T.
    Gaskin, M.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (06) : 1634 - 1639
  • [42] Partial Discharge Direction Finding Method Based on Received Signal Strength and Circular UHF Wireless Sensor Array
    基于接收信号强度和圆形特高频无线传感阵列的局部放电测向方法
    [J]. Luo, Lingen (llg523@sjtu.edu.cn), 1939, Science Press (46): : 1939 - 1947
  • [43] Optimum acoustic sensor placement for partial discharge allocation in transformers
    Hekmati, Arsalan
    Hekmati, Rasoul
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2017, 11 (05) : 581 - 589
  • [44] Study on partial discharge ultrasonic array sensor location method based on the sparse signal decomposition
    Li, Tong
    Xie, Qing
    Zhang, Hongwei
    Li, Jie
    Peng, Peng
    Xu, Yuqin
    [J]. Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2015, 36 (06): : 1301 - 1310
  • [45] Enhancing the Accuracy of Partial Discharge Localization in Power Transformers Using the UHF Measurement Technique
    Azirani, Mohammad Akbari
    Ariannik, Mohamadreza
    Werle, Peter
    Akbari, Asghar
    [J]. 2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 58 - 62
  • [46] Partial Discharge Localization in Transformers Using Monopole and Log-Spiral UHF Sensors
    Sinaga, H. H.
    Phung, B. T.
    Blackburn, T. R.
    [J]. 2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,
  • [47] Investigating Suitable Positions in Power Transformers for Installing UHF Antennas for Partial Discharge Localization
    Mirzaei, H. R.
    Akbari, A.
    Zanjani, M.
    Miralikhani, K.
    Gockenbach, E.
    Borsi, H.
    [J]. PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 625 - 628
  • [48] Recognising multiple partial discharge sources in power transformers by wavelet analysis of UHF signals
    Yang, L
    Judd, MD
    [J]. IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2003, 150 (03) : 119 - 127
  • [49] APPLICATION OF DIGITAL FILTERING TECHNIQUES TO THE DETERMINATION OF PARTIAL DISCHARGE LOCATION IN TRANSFORMERS
    JAMES, RE
    PHUNG, BT
    SU, Q
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1989, 24 (04): : 657 - 668
  • [50] Study on Location of Acoustic Emission Partial Discharge Detection in Power Transformers
    Zhang, Linhai
    Liu, Gang
    Li, Cheng
    Li, Yanming
    Zhang, Longjun
    Lu, Guojun
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 589 - +