Comparison of blue/yellow and frequency doubling technology perimetry in glaucoma patients, glaucoma suspects, and normals

被引:0
|
作者
Langerhorst, CT [1 ]
Carenini, LL [1 ]
Bakker, D [1 ]
Van den Berg, TJTP [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Ophthalmol, NL-1100 DD Amsterdam, Netherlands
来源
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The authors compared two tests designed to measure specific large ganglion cell activity in glaucoma. Forty-six glaucoma patients with early to late damage, 40 glaucoma suspects, 15 ocular hypertensives, and 14 normals were tested with the Humphrey Field Analyzer (HFA) blue/yellow (b/y) full-threshold procedure and with frequency doubling technology (FDT) full-threshold test. The HFA 30-2 white/white (w/w) SITA Standard program was used as a reference standard. Both b/y and FDT showed larger mean deviation and pattern. standard deviation than w/w perimetry in all groups except for the normals. However, after a point-by-point analysis (statistical comparison with normal values) and use of a classification system, FDT was found to be much more accurate than b/y testing, as indicated by receiver operator characteristics (ROC) curve analysis.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [1] Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients
    Horn, FK
    Wakili, N
    Jünemann, AM
    Korth, M
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2002, 240 (08) : 658 - 665
  • [2] Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients
    Folkert K. Horn
    Nina Wakili
    Anselm M. Jünemann
    Matthias Korth
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2002, 240 : 658 - 665
  • [3] The influence of instruction on frequency doubling technology perimetry and Humphrey Matrix results in normals and early glaucoma patients
    Takahashi, G
    Aoki, Y
    Koike, T
    Nakano, T
    Kitahara, K
    Demirel, S
    Johnson, CA
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [4] Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma
    Stefan Serguhn
    Detlev Spiegel
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 351 - 355
  • [5] Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma
    Serguhn, S
    Spiegel, D
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2001, 239 (05) : 351 - 355
  • [6] Frequency doubling perimetry in glaucoma
    Thomas, R
    Bhat, S
    Muliyil, JP
    Parikh, R
    George, R
    [J]. JOURNAL OF GLAUCOMA, 2002, 11 (01) : 46 - 50
  • [7] The ability of frequency doubling technology perimetry in the diagnosis of glaucoma
    Zhao, X
    Xu, L
    Zhang, R
    Ma, Y
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U491 - U491
  • [8] Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma
    Siddiqui, MAR
    Azuara-Blanco, A
    Neville, S
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (12) : 1569 - 1571
  • [9] Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
    Seong Ah Kim
    Chan Kee Park
    Hae-Young Lopilly Park
    [J]. Scientific Reports, 12
  • [10] Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
    Kim, Seong Ah
    Park, Chan Kee
    Park, Hae-Young Lopilly
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)