T staging of gastric cancer: Role of multi-detector row CT

被引:95
|
作者
Kumano, S
Murakami, T
Kim, T
Hori, M
Iannaccone, R
Nakata, S
Onishi, H
Osuga, K
Tomoda, K
Catalano, C
Nakamura, H
机构
[1] Osaka Univ, Dept Radiol, Grad Sch Med, Suita, Osaka 5650871, Japan
[2] Univ Roma La Sapienza, Dept Radiol Sci, Rome, Italy
关键词
D O I
10.1148/radiol.2373041380
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate retrospectively the accuracy of multi-detector row computed tomography (CT) in the assessment of serosal invasion in patients with gastric cancer. MATERIALS AND METHODS: The Ethics Committee does not require approval or informed consent for retrospective studies. Forty-one consecutive patients (24 men, 17 women; mean age, 68 years) with gastric cancer were included in this study. All patients were given 600 mL of tap water to drink and were positioned prone or supine on the scanning table. The detector row configuration included four detector rows, a section thickness of 1.25 mm, a pitch of 6, and a reconstruction interval of 0.63 mm. Transverse and multiplanar reconstruction images were simultaneously evaluated by two independent observers to assess the depth of tumor invasion in the gastric wall (ie, T stage). T staging at multi-detector row CT was compared with T staging at histologic evaluation (reference standard), which was performed by means of surgical or histologic examination of the resected specimen. We also calculated the sensitivity, specificity, and accuracy of multi-detector row CT for each observer in the assessment of serosal invasion. RESULTS: Analysis of interobserver agreement showed substantial or almost perfect agreement (nonweighted kappa value of 0.78 and weighted kappa value of 0.85). Correct assessment of gastric wall invasion was 80% and 85% for observers 1 and 2, respectively. The sensitivity, specificity, and accuracy of multi-detector row CT in the assessment of serosal invasion were 90%, 95%, and 93%, respectively, for observer 1 and 80%, 97%, and 93%, respectively, for observer 2. Overstaging occurred in six patients, and understaging occurred in five patients. All understaged tumors were scirrhous subtype gastric cancer. CONCLUSION: Multi-detector row CT scanning of patients with gastric cancer gave 93% accuracy in the assessment of serosal invasion in patients with gastric cancer. (c) RSNA, 2005.
引用
收藏
页码:961 / 966
页数:6
相关论文
共 50 条
  • [1] Preoperative T staging of gastric cancer by multi-detector row computed tomography
    Makino, Tomoki
    Fujiwara, Yoshiyuki
    Takiguchi, Shuji
    Tsuboyama, Takahiro
    Kim, Tonsok
    Nushijima, Youichirou
    Yamasaki, Makoto
    Miyata, Hiroshi
    Nakajima, Kiyokazu
    Mori, Masaki
    Doki, Yuichiro
    [J]. SURGERY, 2011, 149 (05) : 672 - 679
  • [2] Gastric cancer staging at multi-detector row CT gastrography: Comparison of transverse and volumetric CT scanning
    Kim, HJ
    Kim, AY
    Oh, ST
    Kim, JS
    Kim, KW
    Kim, PN
    Lee, MG
    Ha, HK
    [J]. RADIOLOGY, 2005, 236 (03) : 879 - 885
  • [3] Role of multi-detector row CT angiography in the management of gastric fundal varices
    Matsumoto, A
    Sugano, Y
    Yasuda, M
    Takimoto, K
    [J]. GUT, 2004, 53 (03) : 467 - 467
  • [4] Multi-detector row CT of hemoptysis
    Bruzzi, John F.
    Remy-Jardin, Martine
    Delhaye, Damien
    Teisseire, Antoine
    Khalil, Chadi
    Remy, Jacques
    [J]. RADIOGRAPHICS, 2006, 26 (01) : 3 - U78
  • [5] Acute aortic syndromes: Role of multi-detector row CT
    Salvolini, Luca
    Renda, Pietro
    Fiore, Davide
    Scaglione, Mariano
    Piccoli, GianPiero
    Giovagnoni, Andrea
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (03) : 350 - 358
  • [6] Gastric cancer: Preoperative local staging with 3D multi-detector row CT - Correlation with surgical and histopathologic results
    Chen, Chiao-Yun
    Hsu, Jui-Sheng
    Wu, Deng-Chyang
    Kang, Wan-Yi
    Hsieh, Jan-Sing
    Jaw, Twei-Shiun
    Wu, Ming-Tsang
    Liu, Gin-Chung
    [J]. RADIOLOGY, 2007, 242 (02) : 472 - 482
  • [7] CT: status on multi-detector row scanners
    Martinez-Souloumiac, L.
    Gosso, F.
    [J]. JOURNAL DE RADIOLOGIE, 2006, 87 (7-8): : 927 - 935
  • [8] Detection of submucosal gastric fundal varices with multi-detector row CT angiography
    Willmann, JK
    Weishaupt, D
    Böhm, T
    Pfammatter, T
    Seifert, B
    Marincek, B
    Bauerfeind, P
    [J]. GUT, 2003, 52 (06) : 886 - 892
  • [9] Diagnostic accuracy of endoscopic ultrasonography compared with multi-detector row computerized tomography in staging of early gastric cancer
    Kang, Hyoun Woo
    Kim, Sang Gyun
    Kang, Hae Yeon
    Im, Jong Pil
    Kim, Joo Sung
    Yang, Han-Kwang
    Kim, Se Hyung
    Kim, Woo Ho
    Lee, Kook Lac
    Kim, Ji Won
    Jung, Hyun Chae
    [J]. GASTROINTESTINAL ENDOSCOPY, 2008, 67 (05) : AB220 - AB220
  • [10] Benefits of contrast-enhanced multi-detector row CT colonography for preoperative staging in colorectal cancer patients
    Iinuma, G
    Moriyama, N
    Satake, M
    Miyakawa, K
    Muramatsu, Y
    Tateishi, U
    Akasu, T
    Otake, Y
    Fujii, T
    Kobayashi, T
    [J]. MEDICAL IMAGING 2003: PHYSIOLOGY AND FUNCTION: METHODS, SYSTEMS, AND APPLICATIONS, 2003, 5031 : 398 - 404