A potentiometric, enantioselective membrane electrode for S-ramipril assay

被引:0
|
作者
Stefan, RI [1 ]
van Staden, JF
Baiulescu, GE
Aboul-Enein, HY
机构
[1] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
[2] Univ Bucharest, Fac Chem, Dept Analyt Chem, Bucharest, Romania
[3] King Faisal Specialist Hosp & Res Ctr, Biol & Med Res Dept MBC03, Bioanalyt & Drug Dev Lab, Riyadh 11211, Saudi Arabia
来源
CHEMIA ANALITYCZNA | 1999年 / 44卷 / 3A期
关键词
potentiometric; enantioselective membrane electrode; S-ramipril; 2-hydroxy-3-trimethylammoniopropyl-beta-cyclodextrin (as chloride salt);
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric, enantioselective membrane electrode based on graphite paste (graphite powder and paraffin oil), impregnated with 10(-3) mol l(-1) 2-hydroxy-3-trimethyl-ammoniopropyl-beta-cyclodextrin (as chloride salt) solution, is proposed for S-ramipril assay. This sensor can be used reliably for the assay of S-ramipril as raw material (enantiopurity tests), as well as in its pharmaceutical formulations, in the concentration range from 1.80 x 10(-5) to 2.3 x 10(-1) mol l(-1),with a detection limit of 1 x 10-5 mol l(-1), and with an average recovery of 99.94% (RSD = 0.030%) (recovery test), employing the potentiometric technique. The enantioselectivity was determined versus D-proline. It was shown that L-proline is the only main interfering compound. The surface of the electrode can be regenerated by simply polishing it to obtain a fresh surface which is ready to be used in a new assay.
引用
收藏
页码:417 / 422
页数:6
相关论文
共 50 条
  • [1] A potentiometric, enantioselective membrane electrode for S-Ramipril assay
    Stefan, RI
    van Staden, JF
    Baiulescu, GE
    Aboul-Enein, HY
    CHEMIA ANALITYCZNA, 1999, 44 (03): : 417 - 422
  • [2] Potentiometric enantioselective membrane electrode for s-enalapril assay
    Aboul-Enein, HY
    Stefan, RI
    van Staden, JF
    ANALUSIS, 1999, 27 (01) : 53 - 56
  • [3] S-perindopril assay using a potentiometric, enantioselective membrane electrode
    Stefan, RI
    Van Staden, JF
    Aboul-Enein, HY
    CHIRALITY, 1999, 11 (08) : 631 - 634
  • [4] Biosensors for the enantioselective analysis of S-enalapril and S-ramipril
    Stefan, RI
    Aboul-Enein, HY
    Radu, GL
    PREPARATIVE BIOCHEMISTRY & BIOTECHNOLOGY, 1998, 28 (04): : 305 - 312
  • [5] A new construction for a potentiometric, enantioselective membrane electrode -: its utilization to the S-captopril assay
    Stefan, RI
    van Staden, JF
    Aboul-Enein, HY
    TALANTA, 1999, 48 (05) : 1139 - 1143
  • [6] Enantioselective, potentiometric membrane electrode, based on vancomycin as chiral selector, for the assay of S-perindopril
    Ozoemena, KI
    Stefan, RI
    van Staden, JF
    Aboul-Enein, HY
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2004, 32 (04) : 371 - 378
  • [7] Enantioselective assay of S(+)-ibuprofen using enantioselective, potentiometric membrane electrodes based on maltodextrins
    Stefan-van Staden, Raluca-Ioana
    Mashile, Tumelo R.
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 120 (01): : 295 - 297
  • [8] Utilization of maltodextrin-based enantioselective, potentiometric membrane electrodes for the enantioselective assay of S-flurbiprofen
    Stefan-van Staden, RI
    Bokretsion, RG
    Ozoemena, KI
    ANALYTICAL LETTERS, 2006, 39 (06) : 1065 - 1073
  • [9] Detection of S-enantiomers of cilazapril, pentopril and trandolapril using a potentiometric, enantioselective membrane electrode
    Stefan, RI
    van Staden, JKF
    Aboul-Enein, HY
    ELECTROANALYSIS, 1999, 11 (03) : 192 - 194
  • [10] Enantioselective Determination of R-Clenbuterol Using an Enantioselective, Potentiometric Membrane Electrode Based on a -Cyclodextrin Derivative
    Stefan-van Staden, Raluca-Ioana
    Holo, Luxolo
    Moeketsi, Bakang
    van Staden, Jacobus Frederick
    Aboul-Enein, Hassan Y.
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2009, 37 (02) : 189 - 196