Automated and Accurate Measurement of Aortic Pulse Wave Velocity Using Magnetic Resonance Imaging

被引:4
|
作者
Giri, S. S. [1 ]
Ding, Y. [2 ]
Nishijima, Y. [2 ]
Pedraza-Toseano, A. [2 ]
Burns, P. M. [2 ]
Hamlin, R. L. [2 ]
Simonetti, O. P. [2 ]
机构
[1] Cardiac MRI Res Ctr, 410 W 10th Ave,Room 527 Doan Hall, Columbus, OH 43210 USA
[2] Ohio State Univ, Columbus, OH 43210 USA
来源
COMPUTERS IN CARDIOLOGY 2007, VOL 34 | 2007年 / 34卷
关键词
D O I
10.1109/CIC.2007.4745572
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Arterial stiffness is thought to he a powerful indicator of present and possible future cardiovascular risk. Accordingly, there is an increasing interest in the non-invasive clinical measurement of arterial stiffness. The commonly used non-invasive methods assess aortic Pulse Wave Velocity (PWV) which is known to be a good indicator of aortic stiffness. These methods calculate the PWV by measuring the pressure or flow velocity, at two locations along the aorta to determine the arrival time of the pulse wave; the distance between these locations is measured either on the body surface or using high resolution images. In this study, we have developed a novel method based on MRI that calculates the aortic PWV using multiple locations along the aorta. This approach is largely automatic vis-a-vis aortic segmentation that reduces user-subjectivity; the inclusion of multiple points along aorta increases the accuracy of PWV measurement by averaging.
引用
收藏
页码:661 / +
页数:2
相关论文
共 50 条
  • [21] Measurement of Local Pulse Wave Velocity using Fast Ultrasound Imaging
    Singh, Abhinav Kumar
    Sahani, Ashish Kumar
    2020 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2020,
  • [22] Measuring aortic pulse wave velocity using high-field cardiovascular magnetic resonance: comparison of techniques
    El-Sayed H Ibrahim
    Kevin R Johnson
    Alan B Miller
    Jean M Shaffer
    Richard D White
    Journal of Cardiovascular Magnetic Resonance, 12
  • [23] Measuring aortic pulse wave velocity using high-field cardiovascular magnetic resonance: comparison of techniques
    Ibrahim, El-Sayed H.
    Johnson, Kevin R.
    Miller, Alan B.
    Shaffer, Jean M.
    White, Richard D.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2010, 12
  • [24] Estimation of aortic pulse wave velocity using pulse wave analysis
    McEniery, CM
    Wilson, JC
    Hall, IR
    Cockcroft, JR
    Wilkinson, IB
    JOURNAL OF HYPERTENSION, 2002, 20 : S188 - S189
  • [25] Required temporal resolution for accurate thoracic aortic pulse wave velocity measurements by phase-contrast magnetic resonance imaging and comparison with clinical standard applanation tonometry
    Karolina Dorniak
    Einar Heiberg
    Marcin Hellmann
    Dorota Rawicz-Zegrzda
    Maria Wesierska
    Rafal Galaska
    Agnieszka Sabisz
    Edyta Szurowska
    Maria Dudziak
    Erik Hedström
    BMC Cardiovascular Disorders, 16
  • [26] Required temporal resolution for accurate thoracic aortic pulse wave velocity measurements by phase-contrast magnetic resonance imaging and comparison with clinical standard applanation tonometry
    Dorniak, Karolina
    Heiberg, Einar
    Hellmann, Marcin
    Rawicz-Zegrzda, Dorota
    Wesierska, Maria
    Galaska, Rafal
    Sabisz, Agnieszka
    Szurowska, Edyta
    Dudziak, Maria
    Hedstrom, Erik
    BMC CARDIOVASCULAR DISORDERS, 2016, 16
  • [27] Accurate measurement of the pulse wave delay with imaging photoplethysmography
    Kamshilin, Alexei A.
    Sidorov, Igor S.
    Babayan, Laura
    Volynsky, Maxim A.
    Giniatullin, Rashid
    Mamontov, Oleg V.
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (12): : 5138 - 5147
  • [28] Towards accurate estimation of aortic stiffness and cardiovascular risk: Is a single measurement of pulse wave velocity enough?
    Papaioannou, T.
    Protogerou, A.
    Skliros, N.
    Nasothimiou, E.
    Tzamouranis, P.
    Achimastos, A.
    Papadogiannis, D.
    Stefanadis, C.
    EUROPEAN HEART JOURNAL, 2011, 32 : 548 - 548
  • [29] Accurate measurement of vocal tract shapes using magnetic resonance imaging
    Yang, CS
    Kasuya, H
    Kano, S
    Sato, T
    ELECTRONICS AND COMMUNICATIONS IN JAPAN PART III-FUNDAMENTAL ELECTRONIC SCIENCE, 1995, 78 (08): : 63 - 74
  • [30] Accurate measurement of vocal tract shapes using magnetic resonance imaging
    Yang, Chang-Sheng, 1995, Scripta Technica Inc, New York, NY, United States (78):