Simultaneous measurement of multiparameters using a Sagnac interferometer with polarization maintaining side-hole fiber

被引:90
|
作者
Frazao, O. [1 ]
Silva, S. O. [1 ]
Baptista, J. M. [1 ,2 ]
Santos, J. L. [1 ,3 ]
Statkiewicz-Barabach, G. [4 ]
Urbanczyk, W. [4 ]
Wojcik, J. [5 ]
机构
[1] INESC, P-4169007 Oporto, Portugal
[2] Univ Madeira, Dept Matemat & Engn, P-9000390 Penteada, Funchal, Portugal
[3] Univ Porto, Fac Ciencias, P-4169007 Oporto, Portugal
[4] Wroclaw Univ Technol, PL-50370 Wroclaw, Poland
[5] Marie Curie Sklodowska Univ, PL-20031 Lublin, Poland
关键词
D O I
10.1364/AO.47.004841
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A Sagnac interferometer with a section of a polarization maintaining side-hole fiber for multiparameter measurement is proposed. The sensor was experimentally demonstrated to be sensitive to torsion, temperature, and longitudinal strain, simultaneously The birefringence in the investigated side-hole fiber is induced simultaneously by the elliptical shape of a germanium-doped core and by field overlap with the air holes surrounding the core. The latter effect is purely geometrical and causes high chromatic dispersion of the group birefringence in the long wavelength range, which results in a different period of spectral interference fringes. A different wavelength response is obtained for each interference fringe peak when the fiber is subjected to torsion, temperature, or longitudinal strain. A matrix equation for simultaneous measurement of the three parameters-torsion, temperature, and longitudinal strain-is also proposed. (C) 2008 Optical Society of America
引用
收藏
页码:4841 / 4848
页数:8
相关论文
共 50 条
  • [41] Sagnac loop interferometer based on polarization maintaining photonic crystal fiber with reduced temperature sensitivity
    Kim, DH
    Kang, JU
    OPTICS EXPRESS, 2004, 12 (19): : 4490 - 4495
  • [42] Prototype of the side-hole HB optical fiber
    Wójcik, J
    Urbanczyk, W
    Bock, W
    Janoszczyk, B
    Mergo, P
    Makara, M
    Poturaj, K
    Spytek, W
    OPTICAL FIBERS AND THEIR APPLICATIONS VI, 1999, 3731 : 88 - 93
  • [43] Non-invasive Vital Signs Monitoring Based on Polarization Maintaining Fiber and Sagnac Interferometer
    Qu, Jiaqi
    Shen, Ying
    Xu, Wei
    Tan, Fengze
    Yu, Changyuan
    Yu, Cheungchuen
    2019 24TH OPTOELECTRONICS AND COMMUNICATIONS CONFERENCE (OECC) AND 2019 INTERNATIONAL CONFERENCE ON PHOTONICS IN SWITCHING AND COMPUTING (PSC), 2019,
  • [44] Modelocked fiber laser using the Sagnac interferometer and the nonlinear polarization rotation
    Ibarra-Escamilla, B
    Kuzin, EA
    Haus, JW
    Pottiez, O
    Gómez-García, DE
    Guriérrez-Zainos, F
    Mendosa-Vázquez, S
    Grajales-Coutiño, R
    ADVANCES IN FIBER LASERS, 2003, 4974 : 26 - 35
  • [46] Directional Bending Sensor Based on a Dual Side-Hole Fiber Mach-Zehnder Interferometer
    Tian, Ye
    Chai, Quan
    Tan, Tao
    Mu, Boxin
    Liu, Qiang
    Liu, Yanlei
    Ren, Jing
    Zhang, Jianzhong
    Oh, Kyunghwan
    Lewis, Elfed
    Yang, Jun
    Liu, Zhihai
    Zhang, Wenping
    Yuan, Libo
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2018, 30 (04) : 375 - 378
  • [47] Temperature-Insensitive Pressure Sensor Using a Polarization-Maintaining Photonic Crystal Fiber based Sagnac Interferometer
    Tam, H. Y.
    Khijwania, Sunil K.
    Dong, X. Y.
    AOE 2007: ASIA OPTICAL FIBER COMMUNICATION & OPTOELECTRONIC EXPOSITION & CONFERENCE, CONFERENCE PROCEEDINGS, 2008, : 345 - +
  • [48] Bovine serum albumin detection using side-hole fiber sensors
    Shi, Yan
    Yu, Zhenyu
    Chen, Mengdan
    Lang, Tingting
    OPTICAL FIBER TECHNOLOGY, 2021, 65
  • [49] Pressure sensitivity of side-hole optical fiber sensors
    Clowes, JR
    Syngellakis, S
    Zervas, MN
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1998, 10 (06) : 857 - 859
  • [50] Fabry-Perot Interferometer Based on Etched Side-hole Fiber for Microfluidic Refractive Index Sensing
    Wu, Shengnan
    Yan, Guofeng
    Zhou, Bin
    He, Sailing
    2015 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SENSORS AND APPLICATIONS, 2015, 9620