Monte Carlo simulation of X-ray fluorescence and scattering tomography experiments

被引:10
|
作者
Vincze, L [1 ]
Janssens, K [1 ]
Vekemans, B [1 ]
Adams, F [1 ]
机构
[1] Univ Antwerp, Dept Chem, B-2610 Wilrijk, Belgium
来源
关键词
D O I
10.1117/12.363736
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Experimental data and results from a detailed Monte Carlo (MC) simulation of X-ray Fluorescence, Compton and Rayleigh scattering tomography are presented. The MC model was developed by the authors for aiding the optimization and evaluation of synchrotron radiation induced X-ray fluorescence (SRXRF) experiments. The code simulates complete X-ray fluorescence spectra in the incident energy range of 1-100 keV, including K,L fluorescent lines and Compton, Rayleigh scattering contributions. This generalized simulation model describes the interactions between X-ray photons and heterogeneous samples. The MC code was evaluated by comparisons of simulated and experimental X-ray fluorescent and scattering tomography data. These data were collected at HASYLAB, beamline L (polychromatic setup) and BW5 (monochromatic setup). Good agreement was found between experimental and simulated results.
引用
收藏
页码:328 / 337
页数:10
相关论文
共 50 条
  • [1] A Monte Carlo simulation of scattering reduction in spectral X-ray computed tomography
    Busi, Matteo
    Olsen, Ulrik L.
    Knudsen, Erik B.
    Frisvad, Jeppe R.
    Kehres, Jan
    Christensen, Erik D.
    Khalil, Mohamad
    Haldrup, Kristoffer
    [J]. ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS IV, 2017, 10388
  • [2] X-ray scattering in X-ray fluorescence spectra with X-ray tube excitation - Modelling, experiment, and Monte-Carlo simulation
    Hodoroaba, V. -D.
    Radtke, M.
    Vincze, L.
    Rackwitz, V.
    Reuter, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (24): : 3568 - 3575
  • [3] Monte Carlo simulation of a computed tomography x-ray tube
    Bazalova, Magdalena
    Verhaegen, Frank
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19): : 5945 - 5955
  • [4] X-ray scattering in X-ray fluorescence spectra with X-ray monochromatic, polarised excitation - Modelling, experiment, and Monte-Carlo simulation
    Hodoroaba, V. -D.
    Radtke, M.
    Reinholz, U.
    Riesemeier, H.
    Vincze, L.
    Reuter, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (13): : 1493 - 1498
  • [5] Monte Carlo simulation of X-ray fluorescence spectra: Part 4. Photon scattering at high X-ray energies
    Vincze, L
    Janssens, K
    Vekemans, B
    Adams, F
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (12) : 1711 - 1722
  • [6] Numerical and Monte Carlo Simulation on X-ray Fluorescence Computed Tomography with Self-Absorption Correction
    Jiang, Shanghai
    Wei, Biao
    Feng, Peng
    He, Peng
    Deng, Luzhen
    Chen, Mianyi
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (07) : 1720 - 1726
  • [7] A Monte Carlo study of x-ray fluorescence in x-ray detectors
    Boone, JM
    Seibert, JA
    Sabol, JM
    Tecotzky, M
    [J]. MEDICAL PHYSICS, 1999, 26 (06) : 905 - 916
  • [8] Fullerene-cubane:: X-ray scattering experiments and Monte Carlo simulations
    Verberck, B.
    Heresanu, V.
    Rouziere, S.
    Cambedouzou, J.
    Launois, P.
    Kovats, E.
    Pekker, S.
    Vliegenthart, G. A.
    Michel, K. H.
    Gompper, G.
    [J]. FULLERENES NANOTUBES AND CARBON NANOSTRUCTURES, 2008, 16 (5-6) : 293 - 300
  • [9] Monte Carlo simulation for x-ray detector
    Cai, Houzhi
    Liu, Jinyuan
    Peng, Xiang
    Niu, Lihong
    Peng, Wenda
    Long, Jinghua
    [J]. INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN IMAGING DETECTORS AND APPLICATIONS, 2011, 8194
  • [10] A Monte Carlo simulation of x-ray mammography
    Spyrou, G
    Panayiotakis, G
    Tzanakos, G
    [J]. PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 842 - 843