Functional activity maps based on significance measures and Independent Component Analysis

被引:19
|
作者
Martinez-Murcia, F. J. [1 ]
Gorriz, J. M. [1 ]
Ramirez, J. [1 ]
Puntonet, C. G. [2 ]
Illan, I. A. [1 ]
机构
[1] Univ Granada, Dept Signal Theory Networking & Commun, E-18071 Granada, Spain
[2] Univ Granada, Dept Comp Architecture & Technol, E-18071 Granada, Spain
基金
加拿大健康研究院; 美国国家卫生研究院;
关键词
Alzheimer's Disease (AD); Computer Aided Diagnosis (CAD); Relative Entropy; Independent Component Analysis (ICA); Naive Bayes Classifier; Support Vector Machines (SVM); PET and SPECT; ALZHEIMERS-DISEASE; FEATURE-SELECTION; SPECT IMAGES; DIAGNOSIS; CLASSIFICATION; PET; SEGMENTATION; ALGORITHMS; HMPAO; PCA;
D O I
10.1016/j.cmpb.2013.03.015
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The use of functional imaging has been proven very helpful for the process of diagnosis of neurodegenerative diseases, such as Alzheimer's Disease (AD). In many cases, the analysis of these images is performed by manual reorientation and visual interpretation. Therefore, new statistical techniques to perform a more quantitative analysis are needed. In this work, a new statistical approximation to the analysis of functional images, based on significance measures and Independent Component Analysis (ICA) is presented. After the images preprocessing, voxels that allow better separation of the two classes are extracted, using significance measures such as the Mann-Whitney-Wilcoxon U-Test (MWW) and Relative Entropy (RE). After this feature selection step, the voxels vector is modelled by means of ICA, extracting a few independent components which will be used as an input to the classifier. Naive Bayes and Support Vector Machine (SVM) classifiers are used in this work. The proposed system has been applied to two different databases. A 96-subjects Single Photon Emission Computed Tomography (SPECT) database from the "Virgen de las Nieves" Hospital in Granada, Spain, and a 196-subjects Positron Emission Tomography (PET) database from the Alzheimer's Disease Neuroimaging Initiative (ADNI). Values of accuracy up to 96.9% and 91.3% for SPECT and PET databases are achieved by the proposed system, which has yielded many benefits over methods proposed on recent works. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:255 / 268
页数:14
相关论文
共 50 条
  • [1] Independent Component Analysis with Functional Neuroscience Data Analysis
    Aljobouri H.K.
    Journal of Biomedical Physics and Engineering, 2023, 13 (02): : 169 - 180
  • [2] Independent component analysis for functional neuronal interactions
    Yoshida, A
    Nakagawa, T
    Cao, JT
    Tanaka, S
    8TH INTERNATIONAL CONFERENCE ON NEURAL INFORMATION PROCESSING, VOLS 1-3, PROCEEDING, 2001, : 1403 - 1408
  • [3] Independent component analysis for multivariate functional data
    Virta, Joni
    Li, Bing
    Nordhausen, Klaus
    Oja, Hannu
    JOURNAL OF MULTIVARIATE ANALYSIS, 2020, 176
  • [4] Independent Component Analysis of Functional MRI Data
    Nath, Malaya Ku
    Sahambi, J. S.
    2008 IEEE REGION 10 CONFERENCE: TENCON 2008, VOLS 1-4, 2008, : 1094 - 1099
  • [5] TOPOGRAPHIC PHASE MAPS USING ITERATIVE INDEPENDENT COMPONENT ANALYSIS
    Iyer, Darshan
    Zouridakis, George
    2011 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2011, : 773 - 776
  • [6] Non-linear independent component analysis with diffusion maps
    Singer, Amit
    Coifman, Ronald R.
    APPLIED AND COMPUTATIONAL HARMONIC ANALYSIS, 2008, 25 (02) : 226 - 239
  • [7] Analysis of functional MRI image using independent component analysis
    Shen, MF
    Xu, WL
    Huang, JX
    Beadle, P
    PARALLEL AND DISTRIBUTED COMPUTING: APPLICATIONS AND TECHNOLOGIES, PROCEEDINGS, 2004, 3320 : 127 - 130
  • [8] Quadratic Independent Component Analysis Based on Sparse Component
    Wang, JingHui
    Tang, ShuGang
    MATERIALS ENGINEERING AND MECHANICAL AUTOMATION, 2014, 442 : 562 - 567
  • [9] CO COMPONENT ESTIMATION BASED ON THE INDEPENDENT COMPONENT ANALYSIS
    Ichiki, Kiyotomo
    Kaji, Ryohei
    Yamamoto, Hiroaki
    Takeuchi, Tsutomu T.
    Fukui, Yasuo
    ASTROPHYSICAL JOURNAL, 2014, 780 (01):
  • [10] Electrogastrography based on independent component analysis
    He, Feng
    Li, Gang
    Zhou, Zhenli
    Yu, Xiangyang
    Zhang, Juyuan
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2009, 30 (04): : 871 - 875