The effect of rectal heterogeneity on wall dose in high dose rate brachytherapy

被引:36
|
作者
Kwan, I. S. [1 ]
Wilkinson, D. [1 ]
Cutajar, D. [1 ]
Lerch, M. [1 ]
Rosenfeld, A. [1 ]
Howie, A. [2 ]
Bucci, J. [2 ]
Chin, Y. [2 ]
Perevertaylo, V. L. [3 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
[2] St George Hosp Canc Care Ctr, Kogarah, NSW 2217, Australia
[3] SPA BIT, Kiev, Ukraine
关键词
MOSFET detector; prostate cancer; rectum; high dose rate (HDR) brachytherapy; LOCALIZED PROSTATE-CANCER; HIGH-ENERGY PHOTON; RADIATION-THERAPY; INTERSTITIAL BRACHYTHERAPY; MONTE-CARLO; IN-VIVO; HDR BRACHYTHERAPY; SKIN DOSIMETRY; MOSFET; IR-192;
D O I
10.1118/1.3031111
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
When treating prostate cancer using high dose rate (HDR) brachytherapy, overdosing the rectal wall may lead to post-treatment rectal complications. An area of concern is related to how the rectal wall dose is calculated by treatment planning systems (TPSs). TPSs are used to calculate the dose delivered to the rectal wall, but they assume that the rectum is a water-equivalent homogeneous medium of infinite size and do not consider the effect that an air-filled "empty" rectal cavity would have on the dose absorbed along the rectal wall. The aim of this research is to quantify the effect that an air cavity has on the rectal wall dose, as its presence changes the backscatter conditions in the region. The MO Skin and RADFET dosimeters proved capable of measuring absolute dose with increasing distance from the HDR Ir-192 brachytherapy source. However, the anterior rectal wall doses measured by the MOSkin and RADFET in an empty rectal cavity were 14.7 +/- 0.2% and 13.7 +/- 0.6% lower than the dose measured in a homogeneous rectal phantom. Monte Carlo simulations corroborated the experimentally obtained results, reporting a -13.2 +/- 0.6% difference. The dose measured at the posterior wall of an empty rectal cavity was between 22% and 26% greater than the dose measured in a full rectal cavity. The heterogeneity of the rectal volume appears to have a significant effect on the rectal dose when compared to calculated rectal dose. c 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3031111]
引用
收藏
页码:224 / 232
页数:9
相关论文
共 50 条
  • [21] NEOADJUVANT HIGH DOSE RATE ENDORECTAL BRACHYTHERAPY ALONE FOR OPERABLE RECTAL CANCER
    Vuong, T.
    Tamim, N.
    Ridhard, C.
    Letellier, F.
    Liberman, S.
    Stroian, G.
    Batist, G.
    Morin, N.
    Devic, S.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S41 - S42
  • [22] Pulsed dose rate and fractionated high dose rate brachytherapy: Choice of brachytherapy schedules to replace low dose rate treatments
    Visser, AG
    vandenAardweg, GJMJ
    Levendag, PC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02): : 497 - 505
  • [23] Dose warping uncertainties for the cumulative rectal wall dose from brachytherapy in cervical cancer
    Van Heerden, L. E.
    Van Wieringen, N.
    Koedooder, C.
    Rasch, C. R. N.
    Pieters, B. R.
    Bel, A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S192 - S193
  • [24] High dose rate prostate brachytherapy
    Nickers, P.
    Blanchard, P.
    Hannoun-Levi, J-M
    Bossi, A.
    Chapet, O.
    Guerif, S.
    CANCER RADIOTHERAPIE, 2013, 17 (02): : 118 - 124
  • [25] HIGH-DOSE-RATE BRACHYTHERAPY
    SPEISER, BL
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 116 - 116
  • [26] THE EFFECT OF RECTAL RETRACTOR ON RECTAL DOSE IN GYNECOLOGICAL BRACHYTHERAPY APPLICATIONS
    Tuncel, N.
    Dundar, E.
    Inal, A.
    Aksu, M. G.
    Korcum, A. F.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S190 - S191
  • [27] Rectal bleeding after high-dose-rate brachytherapy combined with hypofractionated external-beam radiotherapy for localized prostate cancer: Impact of rectal dose in high-dose-rate brachytherapy on occurrence of grade 2 or worse rectal bleeding
    Akimoto, Tetsuo
    Katoh, Hiroyuki
    Kitamoto, Yoshizumi
    Tamaki, Tomoaki
    Harada, Kosaku
    Shirai, Katsuyuki
    Nakano, Takashi
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02): : 364 - 370
  • [28] High-dose-rate brachytherapy and pulsed brachytherapy
    Mazeron, JJ
    EUROCANCER 2002, 2002, : 57 - 58
  • [29] The clinical impact of removing rectal gas on high-dose-rate brachytherapy dose distributions for gynecologic cancers
    Vergalasova, Irina
    Ennis, Ronald D.
    Sayan, Mutlay
    Liu, Bo
    Yue, Ning J.
    Hathout, Lara
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (02): : 35 - 41
  • [30] The Impact Of Rectal Distention On The Maximum Rectal Dose Delivered In 3-D Planned High Dose Rate Brachytherapy For Cervical Cancer
    Mayadev, J. S.
    Lim, J.
    Durbin-Johnson, B.
    Mathai, M.
    Stern, R.
    Valicenti, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S456 - S456