共 36 条
Rigid Mini-Thoracoscopy Versus Semirigid Thoracoscopy in Undiagnosed Exudative Pleural Effusion The MINT Randomized Controlled Trial
被引:17
|作者:
Bansal, Shweta
[1
]
Mittal, Saurabh
[1
]
Tiwari, Pavan
[1
]
Jain, Deepali
[2
]
Arava, Sudheer
[2
]
Hadda, Vijay
[1
]
Mohan, Anant
[1
]
Malik, Prabhat
[3
]
Pandey, Ravindra Mohan
[4
]
Khilnani, Gopi C.
[1
]
Guleria, Randeep
[1
]
Madan, Karan
[1
]
机构:
[1] All India Inst Med Sci, Dept Pulm Crit Care & Sleep Med, New Delhi, India
[2] All India Inst Med Sci, Dept Pathol, New Delhi, India
[3] All India Inst Med Sci, Dept Med Oncol, New Delhi, India
[4] All India Inst Med Sci, Dept Biostat, New Delhi, India
关键词:
pleural effusion;
lung cancer;
tuberculosis;
thoracoscopy;
pleura;
DIAGNOSIS;
D O I:
10.1097/LBR.0000000000000620
中图分类号:
R56 [呼吸系及胸部疾病];
学科分类号:
摘要:
Background: There is debate regarding the ideal instrument for medical thoracoscopy. The authors compared rigid mini-thoracoscopy with semirigid thoracoscopy for thoracoscopic pleural biopsy. Methods: Consecutive subjects with undiagnosed exudative pleural effusion were randomized (1:1 ratio) to mini-thoracoscopy or semirigid thoracoscopy groups. The primary objective was a comparison of the diagnostic yield of pleural biopsy. Key secondary outcomes were the comparison of sedative/analgesic dose, operator-rated and patient-rated pain on visual analog scale (VAS), operator-rated overall procedural satisfaction (VAS), pleural biopsy size, and complications between the groups. Results: Of the 88 screened subjects, 73 were randomized: 36 to mini-thoracoscopy and 37 to semirigid thoracoscopy. Diagnostic yield of pleural biopsy in the mini-thoracoscopy (69.4%) and semirigid thoracoscopy groups (81.1%) was similar on intention-to-treat analysis (P=0.25). Although the operator-rated overall procedure satisfaction scores were similar between groups (P=0.87), operator-rated pain [VAS (mean +/- SD), 43.5 +/- 16.7 vs. 31.7 +/- 15.8;P<0.001] and patient-rated pain (VAS, 41.9 +/- 17.3 vs. 32.1 +/- 16.5;P=0.02) scores were greater in the mini-thoracoscopy group. Mean dose of fentanyl and midazolam received was similar between the 2 groups (P=0.28 and 0.68, respectively). Biopsy size was larger in the mini-thoracoscopy group (16.1 +/- 4.5 vs. 8.3 +/- 2.9 mm;P<0.001). Three minor complications occurred in the mini-thoracoscopy group and 6 in the semirigid thoracoscopy group (P=0.11). There were no serious adverse events or procedure-related mortality. Conclusion: Diagnostic yield of rigid mini-thoracoscopy is not superior to semirigid thoracoscopy. Use of semirigid thoracoscope may provide greater patient comfort.