Fluorescence lifetime imaging - techniques and applications

被引:604
|
作者
Becker, W. [1 ]
机构
[1] Becker & Hickl GmbH, D-12277 Berlin, Germany
关键词
FLIM; FRET; TCSPC; TIME-RESOLVED FLUORESCENCE; RESONANCE ENERGY-TRANSFER; MULTIPHOTON EXCITATION; ENDOGENOUS FLUORESCENCE; CHLORIDE HOMEOSTASIS; FREQUENCY-DOMAIN; MICROSCOPY FLIM; LIVE CELLS; HUMAN SKIN; PHOTON;
D O I
10.1111/j.1365-2818.2012.03618.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Fluorescence lifetime imaging (FLIM) uses the fact that the fluorescence lifetime of a fluorophore depends on its molecular environment but not on its concentration. Molecular effects in a sample can therefore be investigated independently of the variable, and usually unknown concentration of the fluorophore. There is a variety of technical solutions of lifetime imaging in microscopy. The technical part of this paper focuses on time-domain FLIM by multidimensional time-correlated single photon counting, time-domain FLIM by gated image intensifiers, frequency-domain FLIM by gain-modulated image intensifiers, and frequency-domain FLIM by gain-modulated photomultipliers. The application part describes the most frequent FLIM applications: Measurement of molecular environment parameters, protein-interaction measurements by Forster resonance energy transfer (FRET), and measurements of the metabolic state of cells and tissue via their autofluorescence. Measurements of local environment parameters are based on lifetime changes induced by fluorescence quenching or conformation changes of the fluorophores. The advantage over intensity-based measurements is that no special ratiometric fluorophores are needed. Therefore, a much wider selection of fluorescence markers can be used, and a wider range of cell parameters is accessible. FLIM-FRET measures the change in the decay function of the FRET donor on interaction with an acceptor. FLIM-based FRET measurement does not have to cope with problems like donor bleedthrough or directly excited acceptor fluorescence. This relaxes the requirements to the absorption and emission spectra of the donors and acceptors used. Moreover, FLIM-FRET measurements are able to distinguish interacting and noninteracting fractions of the donor, and thus obtain independent information about distances and interacting and noninteracting protein fractions. This is information not accessible by steady-state FRET techniques. Autofluorescence FLIM exploits changes in the decay parameters of endogenous fluorophores with the metabolic state of the cells or the tissue. By resolving changes in the binding, conformation, and composition of biologically relevant compounds FLIM delivers information not accessible by steady-state fluorescence techniques.
引用
下载
收藏
页码:119 / 136
页数:18
相关论文
共 50 条
  • [21] Fluorescence lifetime imaging microscopy using rapid lifetime determination method: Theory and applications.
    Periasamy, A
    Sharman, KK
    Demas, JN
    BIOPHYSICAL JOURNAL, 1999, 76 (01) : A10 - A10
  • [22] Applications of ultrafast lasers to two-photon fluorescence and lifetime imaging
    Barry, NP
    Hanson, KM
    Gratton, E
    Clegg, RM
    Behne, MJ
    Mauro, TM
    COMMERCIAL AND BIOMEDICAL APPLICATIONS OF ULTRAFAST AND FREE-ELECTRON LASERS, 2002, 4633 : 50 - 61
  • [23] Fluorescence lifetime imaging microscopy: fundamentals and advances in instrumentation, analysis, and applications
    Datta, Rupsa
    Heaster, Tiffany M.
    Sharick, Joe T.
    Gillette, Amani A.
    Skala, Melissa C.
    JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (07)
  • [24] Construction and applications of a frequency-domain fluorescence lifetime imaging microscope
    Gadella, TWJ
    Goedhart, J
    VanHoek, A
    Visser, AJWG
    PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 1996, 65 : PC121 - PC121
  • [25] Fluorescence lifetime imaging microscopy and its applications in skin cancer diagnosis
    Liu, Lixin
    Yang, Qianqian
    Zhang, Meiling
    Wu, Zhaoqing
    Xue, Ping
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2019, 12 (05)
  • [26] Special issue on fluorescence lifetime imaging (FLIM): from fundamentals to applications
    Ameer-Beg, Simon
    Suhling, Klaus
    Kuimova, Marina
    METHODS AND APPLICATIONS IN FLUORESCENCE, 2020, 8 (04):
  • [27] Referencing techniques for the analog mean-delay method in fluorescence lifetime imaging
    Won, Young Jae
    Moon, Sucbei
    Han, Won-Taek
    Kim, Dug Young
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2010, 27 (11) : 2402 - 2410
  • [28] Fluorescence lifetime imaging ophthalmoscopy
    Dysli, Chantal
    Wolf, Sebastian
    Berezin, Mikhail Y.
    Sauer, Lydia
    Hammer, Martin
    Zinkernagel, Martin S.
    PROGRESS IN RETINAL AND EYE RESEARCH, 2017, 60 : 120 - 143
  • [29] Fluorescence Lifetime Imaging Endoscopy
    Kennedy, G. T.
    Coda, S.
    Thompson, A. J.
    Elson, D. S.
    Neil, M. A. A.
    Stamp, G. W.
    Thillainayagam, A.
    Viellerobe, B.
    Lacombe, F.
    Dunsby, C.
    French, P. M. W.
    ENDOSCOPIC MICROSCOPY VI, 2011, 7893
  • [30] Two postprocessing techniques for the elimination of background autofluorescence for fluorescence lifetime imaging microscopy
    Jones, Phillip B.
    Rozkalne, Aneta
    Meyer-Luehmann, Melanie
    Spires-Jones, Tara L.
    Makarova, Alexandra
    Kumar, Anand T. N.
    Berezovska, Oksana
    Bacskai, Brian B.
    Hyman, Bradley T.
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (01)