Fluorescence lifetime imaging - techniques and applications

被引:604
|
作者
Becker, W. [1 ]
机构
[1] Becker & Hickl GmbH, D-12277 Berlin, Germany
关键词
FLIM; FRET; TCSPC; TIME-RESOLVED FLUORESCENCE; RESONANCE ENERGY-TRANSFER; MULTIPHOTON EXCITATION; ENDOGENOUS FLUORESCENCE; CHLORIDE HOMEOSTASIS; FREQUENCY-DOMAIN; MICROSCOPY FLIM; LIVE CELLS; HUMAN SKIN; PHOTON;
D O I
10.1111/j.1365-2818.2012.03618.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Fluorescence lifetime imaging (FLIM) uses the fact that the fluorescence lifetime of a fluorophore depends on its molecular environment but not on its concentration. Molecular effects in a sample can therefore be investigated independently of the variable, and usually unknown concentration of the fluorophore. There is a variety of technical solutions of lifetime imaging in microscopy. The technical part of this paper focuses on time-domain FLIM by multidimensional time-correlated single photon counting, time-domain FLIM by gated image intensifiers, frequency-domain FLIM by gain-modulated image intensifiers, and frequency-domain FLIM by gain-modulated photomultipliers. The application part describes the most frequent FLIM applications: Measurement of molecular environment parameters, protein-interaction measurements by Forster resonance energy transfer (FRET), and measurements of the metabolic state of cells and tissue via their autofluorescence. Measurements of local environment parameters are based on lifetime changes induced by fluorescence quenching or conformation changes of the fluorophores. The advantage over intensity-based measurements is that no special ratiometric fluorophores are needed. Therefore, a much wider selection of fluorescence markers can be used, and a wider range of cell parameters is accessible. FLIM-FRET measures the change in the decay function of the FRET donor on interaction with an acceptor. FLIM-based FRET measurement does not have to cope with problems like donor bleedthrough or directly excited acceptor fluorescence. This relaxes the requirements to the absorption and emission spectra of the donors and acceptors used. Moreover, FLIM-FRET measurements are able to distinguish interacting and noninteracting fractions of the donor, and thus obtain independent information about distances and interacting and noninteracting protein fractions. This is information not accessible by steady-state FRET techniques. Autofluorescence FLIM exploits changes in the decay parameters of endogenous fluorophores with the metabolic state of the cells or the tissue. By resolving changes in the binding, conformation, and composition of biologically relevant compounds FLIM delivers information not accessible by steady-state fluorescence techniques.
引用
下载
收藏
页码:119 / 136
页数:18
相关论文
共 50 条
  • [1] Fluorescence lifetime imaging techniques for microscopy
    French, T
    So, PTC
    Dong, CY
    Berland, KM
    Gratton, E
    METHODS IN CELL BIOLOGY, VOLUME 56, 1998, 56 : 277 - 304
  • [2] Fluorescence Lifetime Techniques for Biomedical Applications
    Marcu, Laura
    BIOPHYSICAL JOURNAL, 2018, 114 (03) : 6A - 6A
  • [3] Fluorescence Lifetime Techniques in Medical Applications
    Laura Marcu
    Annals of Biomedical Engineering, 2012, 40 : 304 - 331
  • [4] Fluorescence Lifetime Techniques in Medical Applications
    Marcu, Laura
    ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (02) : 304 - 331
  • [5] Fluorescence lifetime imaging in biosciences: technologies and applications
    Raluca Niesner
    Karl-Heinz Gericke
    Frontiers of Physics in China, 2008, 3 : 88 - 104
  • [6] Applications of fluorescence lifetime imaging in clinical medicine
    Wang, Zhanwen
    Zheng, Yanping
    Zhao, Deqiang
    Zhao, Ziwei
    Liu, Lixin
    Pliss, Artem
    Zhu, Feiqi
    Liu, Jun
    Qu, Junle
    Luan, Ping
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2018, 11 (01)
  • [7] Fluorescence lifetime imaging in biosciences: technologies and applications
    Niesner, Raluca
    Gericke, Karl-Heinz
    FRONTIERS OF PHYSICS IN CHINA, 2008, 3 (01): : 88 - 104
  • [8] Introduction: Advanced multiphoton and fluorescence lifetime imaging techniques
    Diaspro, Alberto
    MICROSCOPY RESEARCH AND TECHNIQUE, 2007, 70 (05) : 397 - 397
  • [9] Biological applications of fluorescence lifetime imaging beyond microscopy
    Akers, Walter J.
    Berezin, Mikhail Y.
    Lee, Hyeran
    Guo, Kevin
    Almutairi, Adah
    Frechet, Jean M. J.
    Fischer, Georg M.
    Daltrozzo, Ewald
    Achilefu, Samuel
    REPORTERS, MARKERS, DYES, NANOPARTICLES, AND MOLECULAR PROBES FOR BIOMEDICAL APPLICATIONS II, 2010, 7576
  • [10] FLUORESCENCE LIFETIME IMAGING MICROSCOPY (FLIM) - INSTRUMENTATION AND APPLICATIONS
    WANG, XF
    PERIASAMY, A
    HERMAN, B
    COLEMAN, DM
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1992, 23 (05) : 369 - 395