A comparative study of two large radiative dew water condensers

被引:45
|
作者
Muselli, M
Beysens, D
Millmouk, I
机构
[1] Univ Corse, CNRS, UMR 6134, Ajaccio, France
[2] Int Org Dew Utilizat, F-33600 Pessac, France
[3] CEA Grenoble, Equipe Supercrit Environm Mat & Espace, F-38504 Grenoble, France
[4] Ecole Super Phys & Chim Ind Ville Paris, F-75231 Paris, France
[5] ICMCB, CNRS, ESEME, F-33608 Pessac, France
关键词
dew collection; water production; radiative condenser; water vapor;
D O I
10.1016/j.jaridenv.2005.04.007
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
In order to improve the yield of dew condensation from atmospheric vapor, two large (30 m(2) in area) insulated plane radiative condensers, inclined at 30 degrees, were installed in Ajaccio (Corsica island, France; latitude 41 degrees 55'N, longitude 8 degrees 48'E). Prototype P1 was elevated such that the underside was open and exposed. Prototype P2, however, was enclosed on all sides and closer to the ground. Both used a special radiative foil that enhances dew formation. The period of observation for P1 was July 22, 2000-November 11, 2001, and for P2 was December 10, 2001-December 10, 2003. All data were compared with respect to the same horizontal calibration plate of polymethylmethacrylate (Plexiglas) placed at 1 m above the ground on a sensitive recording balance. Water yield of both prototypes were compared and correlated against meteorological data (cloud cover, relative humidity, wind speed, condenser temperature and air temperature). Both prototypes exhibit improved performances when compared with the calibration plate: more dew days (+ 16% and + 15% for P1 and P2, respectively); decrease of the humidity threshold (-3% and -4.4% for P1 and P2); increase of dew yields for wind speeds up to 3 m s(-1). A model of the mass and thermal exchanges with the ambient air was used. Two adjustable parameters (heat and mass transfer coefficients) are used in the model. The values of these parameters were found larger than the values obtained in continental sites where dew forms with weak wind, thus emphasizing the peculiarities of dew formation in windy islands. When data are reduced with the calibration PMMA data, prototype P1 provided average water yields slightly larger than the enclosed prototype P2, a result that can be attributed to the influence of surface thermal radiation. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:54 / 76
页数:23
相关论文
共 50 条
  • [11] Study of dew water collection in humid tropical islands
    Clus, O.
    Ortega, P.
    Muselli, M.
    Milimouk, I.
    Beysens, D.
    JOURNAL OF HYDROLOGY, 2008, 361 (1-2) : 159 - 171
  • [12] Comparative study on two deployment methods for large subsea spools
    Li, Lin
    Zhu, Xinying
    Parra, Carlos
    Ong, Muk Chen
    OCEAN ENGINEERING, 2021, 233
  • [13] Comparative study on two deployment methods for large subsea spools
    Li, Lin
    Zhu, Xinying
    Parra, Carlos
    Ong, Muk Chen
    Ocean Engineering, 2021, 233
  • [14] LARGE-SCALE DEW COLLECTION AS A SOURCE OF FRESH-WATER SUPPLY
    RAJVANSHI, AK
    DESALINATION, 1981, 36 (03) : 299 - 306
  • [15] INVESTIGATION OF RELATIVE HUMIDITY INFLUENCE ON SORPTION-BASED ATMOSPHERIC WATER HARVESTING PERFORMANCE BY PASSIVE RADIATIVE CONDENSERS
    Bai, S.
    Chao, L. C.
    Pan, A.
    Ho, T. C.
    Tso, C. Y.
    8TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, 2023, : 871 - 880
  • [16] COMPARATIVE STUDY OF WATER RESCUE OCCURRENCES ON TWO BEACHES OF FORTALEZA
    Barbosa Filho, Ruy Paulino
    Crisostomo, Vicente Lima
    de Freitas, Eduardo Benevides
    GEOSABERES, 2021, 12 : 274 - 293
  • [17] Radiative and dissipative flow of hybrid nanofluid between two coaxial cylinders: A comparative numerical study
    Hayat, Tasawar
    Yazman, Muhammad
    Muhammad, Khursheed
    Momani, Shaher
    ALEXANDRIA ENGINEERING JOURNAL, 2023, 71 : 79 - 88
  • [18] A comparative study of two methods of large loop excision of the transformation zone
    Mossa, MA
    Carter, PG
    Abdu, S
    Young, MPA
    Thomas, VA
    Barton, DPJ
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2005, 112 (04) : 490 - 494
  • [19] Comparative analysis of radiative characteristics for two types of waveguide antennas
    Andriychuk, M. I.
    Zamorska, O. F.
    2007 PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON THE EXPERIENCE OF DESIGNING AND APPLICATION OF CAD SYSTEMS IN MICROELECTRONICS, 2007, : 80 - 83
  • [20] Comparative study of two approaches for the prediction of the radiative heat transfer in a participating media subjected to a collimated radiation
    Belhaj Ali, H.
    Askri, F.
    Ben Salah, M.
    Ben Nasrallah, S.
    International Journal of Heat and Technology, 2010, 28 (02) : 125 - 130