A new approach towards simultaneous activity and attenuation reconstruction in emission tomography

被引:51
|
作者
Dicken, V [1 ]
机构
[1] Univ Bremen, Zentrum Technomath, D-28334 Bremen, Germany
关键词
D O I
10.1088/0266-5611/15/4/307
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
In single photon emission computed tomography (SPECT) one is interested in reconstructing the activity distribution f of some radiopharmaceutical. The data gathered suffer from attenuation due to the tissue density mu. Each imaged slice incorporates noisy sample values of the nonlinear attenuated Radon transform A(f, mu)(omega, s) = integral(-infinity)(infinity) f(s omega(perpendicular to) + t omega) exp (-integral(t)(infinity) mu(s omega(perpendicular to) + tau omega) d tau) dt. (1) Traditional theory for SPECT reconstruction treats mu as a known parameter. In practical applications, however, mu is not known, but either crudely estimated, determined in costly additional measurements or plainly neglected. We demonstrate that an approximation of both f and mu from SPECT data alone is feasible, leading to quantitatively more accurate SPECT images. The result is based on nonlinear Tikhonov regularization techniques for parameter estimation problems in differential equations combined with Gauss-Newton-CG minimization.
引用
收藏
页码:931 / 960
页数:30
相关论文
共 50 条
  • [1] NEW APPROACH TO THE EMISSION COMPUTERIZED TOMOGRAPHY PROBLEM - SIMULTANEOUS CALCULATION OF ATTENUATION AND ACTIVITY-COEFFICIENTS
    CENSOR, Y
    GUSTAFSON, DE
    LENT, A
    TUY, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) : 2775 - 2779
  • [2] Simultaneous iterative reconstruction for emission and attenuation images in positron emission tomography
    Glatting, G
    Wuchenauer, M
    Reske, SN
    MEDICAL PHYSICS, 2000, 27 (09) : 2065 - 2071
  • [3] Simultaneous iterative reconstruction of emission and attenuation images in positron emission tomography.
    Glatting, G
    Wuchenauer, M
    Reske, SN
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 195P - 195P
  • [4] Simultaneous activity attenuation reconstruction in positron emission tomography via maximum likelihood and iterative methods
    De Pierro, AR
    Crepaldi, F
    2005 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), VOLS 1-5, 2005, : 3545 - 3548
  • [5] SIMULTANEOUS RECONSTRUCTION OF EMISSION AND ATTENUATION IN PASSIVE GAMMA EMISSION TOMOGRAPHY OF SPENT NUCLEAR FUEL
    Backholm, Rasmus
    Bubba, Tatiana A.
    Belanger-Champagne, Camille
    Helin, Tapio
    Dendooven, Peter
    Siltanen, Samuli
    INVERSE PROBLEMS AND IMAGING, 2020, 14 (02) : 317 - 337
  • [6] Simultaneous iterative reconstruction of emission and attenuation images in positron emission tomography from emission data only
    Landmann, M
    Reske, SN
    Glatting, G
    MEDICAL PHYSICS, 2002, 29 (09) : 1962 - 1967
  • [7] Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms
    Nuyts, J
    Dupont, P
    Stroobants, S
    Benninck, R
    Mortelmans, L
    Suetens, P
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (05) : 393 - 403
  • [8] Differential attenuation method for simultaneous estimation of activity and attenuation in multiemission single photon emission computed tomography
    Kaplan, MS
    Haynor, DR
    MEDICAL PHYSICS, 1999, 26 (11) : 2333 - 2340
  • [9] Analytic reconstruction algorithms in emission tomography with variable attenuation
    Kunyansky, Leonid A.
    Journal of Computational Methods in Sciences and Engineering, 2001, 1 (2-3) : 267 - 286
  • [10] Simultaneous Reconstruction of Activity and Attenuation for PET/MR
    Salomon, Andre
    Goedicke, Andreas
    Schweizer, Bernd
    Aach, Til
    Schulz, Volkmar
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (03) : 804 - 813