SIMULTANEOUS RECONSTRUCTION OF EMISSION AND ATTENUATION IN PASSIVE GAMMA EMISSION TOMOGRAPHY OF SPENT NUCLEAR FUEL

被引:11
|
作者
Backholm, Rasmus [1 ,2 ]
Bubba, Tatiana A. [1 ]
Belanger-Champagne, Camille [2 ,3 ]
Helin, Tapio [4 ]
Dendooven, Peter [2 ]
Siltanen, Samuli [1 ]
机构
[1] Univ Helsinki, Dept Math & Stat, FI-00014 Helsinki, Finland
[2] Univ Helsinki, Helsinki Inst Phys, FI-00014 Helsinki, Finland
[3] TRIUMF, Vancouver, BC V6T 2A3, Canada
[4] LUT Univ, Sch Engn Sci, FI-53850 Lappeenranta, Finland
基金
芬兰科学院;
关键词
non-linear ill-posed inverse problem; passive gamma emission tomography (PGET); simultaneous reconstruction; spent nuclear fuel; SPECT EMISSION; ALGORITHM;
D O I
10.3934/ipi.2020014
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
In the context of international nuclear safeguards, the International Atomic Energy Agency (IAEA) has recently approved passive gamma emission tomography (PGET) as a method for inspecting spent nuclear fuel assemblies (SFAs). The PGET instrument is essentially a single photon emission computed tomography (SPECT) system that allows the reconstruction of axial cross-sections of the emission map of an SFA. The fuel material heavily self-attenuates its gamma-ray emissions, so that correctly accounting for the attenuation is a critical factor in producing accurate images. Due to the nature of the inspections, it is desirable to use as little a priori information as possible about the fuel, including the attenuation map, in the reconstruction process. Current reconstruction methods either do not correct for attenuation, assume a uniform attenuation throughout the fuel assembly, or assume an attenuation map based on an initial filtered back-projection reconstruction. We propose a method to simultaneously reconstruct the emission and attenuation maps by formulating the reconstruction as a constrained minimization problem with a least squares data fidelity term and regularization terms. Using simulated data, we show that our approach produces clear reconstructions which allow for a highly reliable classification of spent, missing, and fresh fuel rods.
引用
收藏
页码:317 / 337
页数:21
相关论文
共 50 条
  • [1] Gamma Emission Tomography for the Inspection of Spent Nuclear Fuel
    Mayorov, Mikhail
    White, Timothy
    Lebrun, Alain
    Brutscher, Joerg
    Keubler, Jens
    Birnbaum, Andre
    Ivanov, Victor
    Honkamaa, Tapani
    Peura, Pauli
    Dahlberg, Joakim
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [2] Improved Passive Gamma Emission Tomography image quality in the central region of spent nuclear fuel
    Riina Virta
    Tatiana A. Bubba
    Mikael Moring
    Samuli Siltanen
    Tapani Honkamaa
    Peter Dendooven
    Scientific Reports, 12
  • [3] Effect of Gamma-Ray Energy on Image Quality in Passive Gamma Emission Tomography of Spent Nuclear Fuel
    Belanger-Champagne, Camille
    Peura, Pauli
    Eerola, Paula
    Honkamaa, Tapani
    White, Timothy
    Mayorov, Mikhail
    Dendooven, Peter
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (01) : 487 - 496
  • [4] Bayesian Activity Estimation and Uncertainty Quantification of Spent Nuclear Fuel Using Passive Gamma Emission Tomography
    Eldaly, Ahmed Karam
    Fang, Ming
    Di Fulvio, Angela
    McLaughlin, Stephen
    Davies, Mike E.
    Altmann, Yoann
    Wiaux, Yves
    JOURNAL OF IMAGING, 2021, 7 (10)
  • [5] Author Correction: Improved Passive Gamma Emission Tomography image quality in the central region of spent nuclear fuel
    Riina Virta
    Tatiana A. Bubba
    Mikael Moring
    Samuli Siltanen
    Tapani Honkamaa
    Peter Dendooven
    Scientific Reports, 12 (1)
  • [6] Simultaneous iterative reconstruction for emission and attenuation images in positron emission tomography
    Glatting, G
    Wuchenauer, M
    Reske, SN
    MEDICAL PHYSICS, 2000, 27 (09) : 2065 - 2071
  • [7] Simultaneous iterative reconstruction of emission and attenuation images in positron emission tomography.
    Glatting, G
    Wuchenauer, M
    Reske, SN
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 195P - 195P
  • [8] Improved Passive Gamma Emission Tomography image quality in the central region of spent nuclear fuel (Vol 12, 12473, 2022)
    Virta, Riina
    Bubba, Tatiana A.
    Moring, Mikael
    Siltanen, Samuli
    Honkamaa, Tapani
    Dendooven, Peter
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [9] Simultaneous passive neutron interrogation and gamma spectroscopy on spent nuclear fuel
    Nicolaou, G
    Abbas, K
    Koch, L
    TOPSEAL '96 -INTERNATIONAL TOPICAL MEETING: DEMONSTRATING THE PRACTICAL ACHIEVEMENTS OF NUCLEAR WASTE MANAGEMENT AND DISPOSAL, VOL II: POSTER PAPERS, 1996, : 79 - 82
  • [10] Simultaneous iterative reconstruction of emission and attenuation images in positron emission tomography from emission data only
    Landmann, M
    Reske, SN
    Glatting, G
    MEDICAL PHYSICS, 2002, 29 (09) : 1962 - 1967