Reproducibility and cost of blood pressure self-measurement using the 'Loaned Self-measurement Equipment Model'

被引:4
|
作者
Calvo-Vargas, C
Rios, VP
Troyo-Sanromán, R
Grover-Paez, F
机构
[1] Inst Mexicano Seguro Social, Unidad Med Familiar, Mexico City, DF, Mexico
[2] Univ Guadalajara, Dept Physiol, Guadalajara, Jalisco, Mexico
[3] Univ Guadalajara, Hosp Civil Juan I Menchaca, Guadalajara, Jalisco, Mexico
关键词
blood pressure measurement; home blood pressure; hypertension; reproducibility;
D O I
10.1097/00126097-200110000-00001
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To determine the reproducibility and the cost of the Loaned Self-measurement Equipment Model for blood pressure. Subjects Seventy-five subjects with non-complicated essential hypertension, having an average age of 56.2 +/- 11 years, were evaluated. Methods The Loaned Self-measurement Equipment Model consists of a set of sphygmomanometers belonging to the clinic, loaned to patients for 3-day periods for them to carry out 27 readings, and then returned. Using a mercury sphygmomanometer, a nurse carried out office blood pressure readings during two visits. A month later, the same procedure was repeated under the same clinical conditions. The agreement between studies was assessed by correlation coefficients, coefficients of variation and standard deviation of the differences (SDD). Results The office blood pressure was 147 +/- 17/89 +/- 12 mmHg during visit A, and 145 +/- 16/ 88 +/- 11 mmHg during visit B. The self-measurement blood pressure was 139 +/- 16/84 +/- 10 mmHg during the first visit, and 136 +/- 15/84 +/- 11 mmHg during the second visit. In neither of the cases were the differences statistically significant. The correlation coefficients for the office and self-measurement systolic blood pressure were statistically significant (P=0.018), while those for the diastolic blood pressure were not statistically significant. The SDD for self-measurement systolic blood pressure was 10.7, compared to 15.0 for the off ice blood pressure (P < 0.01). The comparison in the case of diastolic blood pressure was not significant. The cost of each loan was $5.85 (US dollars). Conclusions The Loaned Self-measurement Equipment Model has a good short-term reproducibility, and the cost is reasonable. (C) 2001 Lippincott Williams Wilkins.
引用
收藏
页码:225 / 232
页数:8
相关论文
共 50 条
  • [31] The value of blood pressure self-measurement by patients with hypertension
    Gorbunov, VM
    [J]. KARDIOLOGIYA, 2002, 42 (01) : 58 - 66
  • [32] Self-Measurement of Blood Pressure at Home in the Management of Hypertension
    Celis, Hilde
    Den Hond, Elly
    Staessen, Jan
    [J]. CLINICAL MEDICINE & RESEARCH, 2005, 3 (01) : 19 - 26
  • [33] Video training for blood-pressure self-measurement
    Postel-Vinay, N
    Chatellier, G
    Bobrie, G
    Donzel, M
    Plouin, PF
    Ménard, J
    [J]. JOURNAL OF HYPERTENSION, 2004, 22 : S159 - S160
  • [34] Blood pressure self-measurement: sensible or irrational choice?
    Bouhanick, B.
    [J]. DIABETES & METABOLISM, 2007, 33 : S80 - S81
  • [35] Usefulness of the loaned self-measurement equipment model for diagnosis and treatment adjustment during a clinical trial using valsartan.
    Calvo-Vargas, CG
    Galarza, D
    Garcia-Gutiérrez, C
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 140A - 140A
  • [36] SELF-MEASUREMENT OF BLOOD-GLUCOSE
    SCOTT, RS
    BEAVEN, DW
    [J]. NEW ZEALAND MEDICAL JOURNAL, 1982, 95 (719) : 772 - 773
  • [37] A Technique for Self-Measurement
    Slotkin, Herman
    [J]. PERSONNEL AND GUIDANCE JOURNAL, 1954, 32 (07): : 415 - 416
  • [38] Telemonitoring of blood pressure self-measurement (BPSM) in the OLMETEL study
    Uen, S
    Ewald, S
    Kaufmann, S
    Vor Dem Esche, J
    Mengden, T
    [J]. JOURNAL OF HYPERTENSION, 2004, 22 : S26 - S26
  • [39] Determination of normality limit of blood pressure by home self-measurement
    Cia Huarte, A.
    Fanlo Mateo, P.
    Uranga Aguirre, J.
    Ezcurdia Irurzun, E.
    Berrade Marticorena, F.
    Tiberio Lopez, G.
    [J]. REVISTA CLINICA ESPANOLA, 2006, 206 (07): : 305 - 313
  • [40] Use of the median for the evaluation of blood pressure self-measurement (BPSM)
    Lijarcio, Manuel Amaro
    Yuste, Enrique Angulo
    Senso, Adolfo Arias
    Aparicio, Javier Blanco
    de la Pena Ruiz, Jose Antonio
    Garcia, Manuel Diez
    Tobal, Francisca Galindo
    Martinez Llarena, Maria Luisa
    Garcia, Candido Mena
    Cano, Francisco Parralejo
    Perez Castan, Jose F.
    Robles Perez-Monteoliva, Nicolas R.
    Santos, Natividad Sanchez
    [J]. EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2007, 18 (01) : 31 - 34