The Effect of Condensate Water on the Performance of Automotive Air Conditioning System under Difference Evaporator Air Inlet Temperature

被引:0
|
作者
Sukri, Mohamad Firdaus [1 ,2 ]
Lokman, Rusmiati [2 ]
Muhajir, Asjufri [2 ]
Wasbari, Faizil [1 ,2 ]
Damanhuri, Amir Abdullah Muhamad [1 ]
Sumeru, Kasni [3 ]
机构
[1] Univ Tekn Malaysia Melaka, Green & Efficient Energy Technol GrEET Res Grp, Durian Tunggal 76100, Melaka, Malaysia
[2] Univ Tekn Malaysia Melaka, Fak Kejuruteraan Mekanikal, Durian Tunggal 76100, Melaka, Malaysia
[3] Politekn Negeri Bandung Gegerkalong Hilir Ciwarug, Dept Refrigerat & Air Conditioning, Bandung 40012, Indonesia
关键词
Vapour Compression Refrigeration Cycle; Air Conditioning System; Condensate Water; Sub-Cooling Method; COP Improvement; ENERGY;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper experimentally investigates the effect of condensate water on the performance of automotive air conditioning (AAC) system under difference evaporator air inlet temperature. An experimental test rig was fabricated using the actual component of AAC system used for Proton Wira passenger car. During experimental work, the volume flow rate of condensate water was manipulated at 0, 140 and 340 ml/min. The evaporator air inlet temperature was also varied at 28, 32 and 36 degrees C. The other parameters of compressor speed, condensate water temperature and condenser air inlet temperature were kept constant at 1550 rpm, 29 +/- 1 degrees C and 32 +/- 1 degrees C, respectively. The study showed that the coefficient of performance (COP) of the AAC system increases when the volume flow rate of condensate water increased from 0 to 140 ml/min. It was due to a dominant decrease in compressor work, as compared to the drop in cooling capacity. In addition, the highest increment in COP occurred at evaporator air inlet temperature of 36 degrees C (9.8%), followed by evaporator air inlet temperature of 28 degrees C (2.8%) and 32 degrees C (0.4%). The highest COP is 3.66, occurred at evaporator air inlet temperature of 32 degrees C and volume flow rate of condensate water of around 140 ml/min.
引用
收藏
页码:85 / 93
页数:9
相关论文
共 50 条
  • [1] Effect of Variation in Evaporator Inlet Air Temperature on Coefficient of Performance in an Automotive Air Conditioning System
    Abdulla, S.
    Ravikumar, T.S.
    Balaji, D.
    Hariram, V.
    [J]. International Journal of Vehicle Structures and Systems, 2022, 14 (05) : 559 - 562
  • [2] ANALYSIS OF THE PERFORMANCE OF THE EVAPORATOR OF AUTOMOTIVE AIR CONDITIONING SYSTEM
    Shen, C. C.
    Lu, J. H.
    [J]. INTERNATIONAL JOURNAL OF AUTOMOTIVE TECHNOLOGY, 2014, 15 (01) : 19 - 38
  • [3] Analysis of the performance of the evaporator of automotive air conditioning system
    C. C. Shen
    J. H. Lu
    [J]. International Journal of Automotive Technology, 2014, 15 : 19 - 38
  • [4] Influence of refrigerant charge and air inlet temperatures on the performance of an automotive air conditioning system
    20171403535340
    [J]. (1) LETEF, Universidade do Vale do Rio dos Sinos, 950 Unisinos Ave, São Leopoldo; 93022-000, Brazil, 1600, Chemours; Daikin Industries, Ltd.; Denso Corporation; et al.; Fuji Electric Co., Ltd.; Fujitsu General Limited (International Institute of Refrigeration):
  • [5] Experimental study on the effect of condensate water on the performance of split air conditioning system
    Yang, Hua
    Pei, Na
    Liu, Liansheng
    Fan, Man
    Qin, Yue
    [J]. ENERGY REPORTS, 2021, 7 : 840 - 851
  • [6] Thermal and hydraulic analysis of compact evaporator for automotive air-conditioning system
    Lee, KH
    Won, JP
    [J]. VTMS 4: VEHICLE THERMAL MANAGEMENT SYSTEMS, 1999, : 91 - 104
  • [7] Vapor quality and performance of an automotive air conditioning system
    Wang, SJ
    Gu, JJ
    Dickson, T
    Dexter, J
    McGregor, I
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2005, 30 (01) : 59 - 66
  • [8] Experimental investigation on the performance of residential air conditioning system using water condensate for subcooling
    Sumeru, Kasni
    Pramudantoro, Triaji Pangripto
    Setyawan, Andriyanto
    [J]. 3RD ANNUAL APPLIED SCIENCE AND ENGINEERING CONFERENCE (AASEC 2018), 2018, 197
  • [9] Enhancement of condensate water quantity and coefficient of performance of an air conditioning system: An experimental study
    Meher, Raghavarapu Satya
    Jaikumar, Sagari
    [J]. HEAT TRANSFER, 2021, 50 (05) : 4144 - 4151
  • [10] Energetic performance evaluation of an automotive CO2 air conditioning system with a dual-evaporator configuration
    Lei, Qiang
    Song, Xia
    Yu, Binbin
    Liu, Cichong
    Shi, Junye
    Chen, Jiangping
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 152 : 356 - 368