Effects of Roof Bolter Canopy Air Curtain on Airflow and Dust Dispersion in an Entry Using Exhaust Curtain Ventilation

被引:3
|
作者
Zheng, Y. [1 ]
Reed, W. R. [1 ]
机构
[1] NIOSH, Ctr Dis Control & Prevent CDC, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USA
关键词
Canopy air curtain (CAC); Roof bolting machine; Dust control; Computational fluid dynamics (CFD); COAL-WORKERS; PNEUMOCONIOSIS; MINERS;
D O I
10.1007/s42461-020-00294-7
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
A recent study conducted by the National Institute for Occupational Safety and Health (NIOSH) evaluated the roof bolter canopy air curtain (CAC) system in a blowing face ventilation system, demonstrating its effectiveness and illustrating the CAC protection zones. This study evaluates the roof bolter machine CAC while operating in an exhausting face ventilation system. This study considers two similar locations to allow comparison with the previous blowing face ventilation (Zheng et al., Min Metal Explor 36(6):1115-1126, (2019)) study: (1) a roof bolter machine bolting the roof at 20 ft (6.1 m) from the face and (2) a roof bolting machine bolting at 4 ft (1.2 m) from the face. The environment introduces 6.0 mg/m(3)of respirable dust to represent the roof bolting machine operating downstream of the continuous miner. However, the exhausting face ventilation uses an exhaust curtain with 9000 cfm (4.25 m(3)/s) of air. Two roof bolter machine working positions are simulated with the use of dual drill heads in the inward position for two inside bolts and in the outward position for two outside bolts. The influence of the CAC on airflows and dust dispersion is evaluated with the CAC operating at 250 cfm (0.12 m(3)/s) with dust reductions ranging from 39.5 to 82.8%. When the roof bolter machine operated close to the face, increasing CAC airflow was required for adequate protection since the dust reductions can be as low as 39.5%. Additional CAC airflows of 350 cfm (0.17 m(3)/s) and 450 cfm (0.21 m(3)/s) were evaluated and demonstrated that dust reductions increased to 59.7% (350 cfm) and 72.0% (450 cfm) for the worst location where the roof bolter operators located.
引用
收藏
页码:1865 / 1875
页数:11
相关论文
共 41 条
  • [21] Study of using air curtain control the respiratory dust at the location of the operator
    Wu, Qiang
    Wang, Haiqiao
    Chu, Xiusheng
    Xie, Hong
    Proceedings in Mining Science and Safety Technology, 2002, : 411 - 418
  • [22] Study of using air curtain control the respiratory dust at the location of the operator
    Wu, Q
    Wang, HQ
    Chu, XS
    Xie, H
    PROCEEDINGS IN MINING SCIENCE AND SAFETY TECHNOLOGY, 2002, : 411 - 418
  • [24] The Study on Changes of Exhaust Efficiency and Fine Particle Concentration at a Ventilation Opening by a Air Curtain Flow in a Subway Model Tunnel
    Han, Bangwoo
    Kim, Hak-Joon
    Kim, Yong-Jin
    Jeong, Sang-Hyeon
    Kim, Yong-Min
    Kim, Jong-Ryul
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2011, 27 (05) : 614 - 622
  • [25] Experimental study of the effects of air volume ratios on the air curtain dust cleaning in fully mechanized working face
    Wang, Hao
    Cheng, Weimin
    Sa, Zhanyou
    Liu, Jie
    Zhang, Ran
    Chen, Dawei
    JOURNAL OF CLEANER PRODUCTION, 2021, 293
  • [26] Performance evaluation for a coupled push-pull ventilation and air curtain system to restrict pollutant dispersion in a factory building
    Wang, Jihong
    Huo, Qiannan
    Zhang, Tengfei
    Liu, Fei
    Wang, Shugang
    Ma, Zhenjun
    Jiang, Shuang
    JOURNAL OF BUILDING ENGINEERING, 2021, 43
  • [27] Dust dispersion law and high-pressure air curtain control technology of crossheading during the process of ore unloading
    Wang, Jiuzhu
    Du, Cuifeng
    Du, Shuai
    Jin, Weibo
    Fan, Dezhen
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2022, 230
  • [28] The impacts of the axial-to-radial airflow quantity ratio and suction distance on air curtain dust control in a fully mechanized coal face
    Wang, Hao
    Cheng, Weimin
    Sun, Biao
    Yu, Haiming
    Jin, Hu
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 25 (08) : 7808 - 7822
  • [29] The impacts of the axial-to-radial airflow quantity ratio and suction distance on air curtain dust control in a fully mechanized coal face
    Hao Wang
    Weimin Cheng
    Biao Sun
    Haiming Yu
    Hu Jin
    Environmental Science and Pollution Research, 2018, 25 : 7808 - 7822
  • [30] Effects of radial air flow quantity and location of an air curtain generator on dust pollution control at fully mechanized working face
    Wang, Hao
    Cheng, Weimin
    Sun, Biao
    Ma, Youying
    ADVANCED POWDER TECHNOLOGY, 2017, 28 (07) : 1780 - 1791