Titanium-zirconium narrow-diameter versus titanium regular-diameter implants for anterior and premolar single crowns: 1-year results of a randomized controlled clinical study

被引:42
|
作者
Benic, Goran I. [1 ]
Gallucci, German O. [2 ]
Mokti, Muizzaddin [2 ]
Haemmerle, Christoph H. F. [1 ]
Weber, Hans-Peter [3 ]
Jung, Ronald E. [1 ]
机构
[1] Univ Zurich, Ctr Dent Med, Clin Fixed & Removable Prosthodont & Dent Mat Sci, CH-8032 Zurich, Switzerland
[2] Harvard Univ, Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA 02115 USA
[3] Tufts Univ, Sch Dent Med, Dept Prosthodont & Operat Dent, Boston, MA 02111 USA
关键词
crown; dental implants; diameter; fixed partial denture; humans; narrow; radiographic; randomized controlled trial; survival; titanium; titanium-zirconium; MECHANICAL-PROPERTIES; SURVIVAL RATE; TOOTH; RESTORATIONS; SITES;
D O I
10.1111/jcpe.12156
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AimTo test whether titanium-zirconium (TiZr) 3.3mm diameter implants perform differently from titanium (Ti) 4.1mm diameter implants with respect to marginal bone level (MBL) and clinical parameters. Material and MethodsForty subjects in need of a single implant-supported crown in the anterior or premolar regions were recruited in two centres. After random allocation, either a Ti or a TiZr implant was placed. Definitive crowns were inserted 6months after implant placement. Implant survival, change in MBL, clinical parameters and occurrence of adverse events were assessed at the 1-year examination. ResultsAt 1year, 38 of the 40 included patients were examined (18 Ti and 20 TiZr implants). All the implants were in place and stable. From the implant placement to the 1-year examination, the change of MBL amounted to -0.40mm in the Ti group and -0.41mm in the TiZr group. There were no significant differences between the groups regarding the change in MBL, the clinical parameters and the occurrence of adverse events. ConclusionsThe use of TiZr implants with narrow diameter for the support of single crowns in the anterior and premolar regions leads to successful tissue integration and clinical performance over a 1-year period.
引用
收藏
页码:1052 / 1061
页数:10
相关论文
共 50 条
  • [41] Clinical performance of titanium-zirconium implants with a hydrophilic surface in patients with controlled type 2 diabetes mellitus: 2-year results from a prospective case-control clinical study
    José J. Cabrera-Domínguez
    Lizett Castellanos-Cosano
    Daniel Torres-Lagares
    Manuel Pérez-Fierro
    Guillermo Machuca-Portillo
    [J]. Clinical Oral Investigations, 2020, 24 : 2477 - 2486
  • [42] Clinical performance of titanium-zirconium implants with a hydrophilic surface in patients with controlled type 2 diabetes mellitus: 2-year results from a prospective case-control clinical study
    Cabrera-Dominguez, Jose J.
    Castellanos-Cosano, Lizett
    Torres-Lagares, Daniel
    Perez-Fierro, Manuel
    Machuca-Portillo, Guillermo
    [J]. CLINICAL ORAL INVESTIGATIONS, 2020, 24 (07) : 2477 - 2486
  • [43] Clinical, Esthetic, and Radiographic Evaluation of Small-Diameter (3.0-mm) Implants Supporting Single Crowns in the Anterior Region: A 3-Year Prospective Study
    Pieri, Francesco
    Siroli, Lucia
    Forlivesi, Caterina
    Corinaldesi, Giuseppe
    [J]. INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2014, 34 (06) : 825 - 832
  • [44] Immediate provisionalisation of single post-extractive implants versus implants placed in healed sites in the anterior maxilla: 1-year results from a multicentre controlled cohort study
    Grandi, Tommaso
    Guazzi, Paolo
    Samarani, Rawad
    Grandi, Giovanni
    [J]. EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2013, 6 (03) : 285 - 295
  • [45] A multicenter randomized controlled clinical pilot study of buccally micro-veneered lithium-disilicate and zirconia crowns supported by titanium base abutments: 1-year outcomes
    Strasding, Malin
    Hicklin, Stefan Paul
    Todorovic, Ana
    Fehmer, Vincent
    Mojon, Philippe
    Sailer, Irena
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (01) : 56 - 65
  • [46] Five-year results of a randomized controlled clinical trial comparing zirconia and titanium abutments supporting single-implant crowns in canine and posterior regions
    Zembic, Anja
    Boesch, Adrian
    Jung, Ronald E.
    Haemmerle, Christoph H. F.
    Sailer, Irena
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (04) : 384 - 390
  • [47] A Pilot Study of Small-Diameter One-Piece Ceramic Implants Placed in Anterior Regions: Clinical and Esthetic Outcomes at 1-Year Follow-up
    Kunavisarut, Chatchai
    Buranajanyakul, Leerawan
    Kitisubkanchana, Jira
    Pumpaluk, Piyapanna
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (05) : 965 - 973
  • [48] Evaluation of the clinical safety and performance of a narrow diameter (2.9 mm) bone-level implant: a 1-year prospective single-arm multicenter study
    Christian Walter
    Keyvan Sagheb
    Sebastian Blatt
    Marcus Oliver Klein
    Jan Herrmann
    Johannes Kleinheinz
    Bilal Al-Nawas
    [J]. International Journal of Implant Dentistry, 9
  • [49] Evaluation of the clinical safety and performance of a narrow diameter (2.9 mm) bone-level implant: a 1-year prospective single-arm multicenter study
    Walter, Christian
    Sagheb, Keyvan
    Blatt, Sebastian
    Klein, Marcus Oliver
    Herrmann, Jan
    Kleinheinz, Johannes
    Al-Nawas, Bilal
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01)
  • [50] Immediate nonocclusal versus early loading of dental implants in partially edentulous patients: 1-year results from a multicenter, Randomized controlled clinical trial
    Testori, Tiziano
    Galli, Fabio
    Capelli, Matteo
    Zuffetti, Francesco
    Esposito, Marco
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (05) : 815 - 822