Energy-resolved computed tomography: first experimental results

被引:190
|
作者
Shikhaliev, Polad M. [1 ]
机构
[1] Louisiana State Univ, Dept Phys & Astron, Imaging Phys Lab, Baton Rouge, LA 70803 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2008年 / 53卷 / 20期
关键词
D O I
10.1088/0031-9155/53/20/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
First experimental results with energy-resolved computed tomography (CT) are reported. The contrast-to-noise ratio (CNR) in CT has been improved with x-ray energy weighting for the first time. Further, x-ray energy weighting improved the CNR in material decomposition CT when applied to CT projections prior to dual-energy subtraction. The existing CT systems use an energy (charge) integrating x-ray detector that provides a signal proportional to the energy of the x-ray photon. Thus, the x-ray photons with lower energies are scored less than those with higher energies. This underestimates contribution of lower energy photons that would provide higher contrast. The highest CNR can be achieved if the x-ray photons are scored by a factor that would increase as the x-ray energy decreases. This could be performed by detecting each x-ray photon separately and measuring its energy. The energy selective CT data could then be saved, and any weighting factor could be applied digitally to a detected x-ray photon. The CT system includes a photon counting detector with linear arrays of pixels made from cadmium zinc telluride (CZT) semiconductor. A cylindrical phantom with 10.2 cm diameter made from tissue-equivalent material was used for CT imaging. The phantom included contrast elements representing calcifications, iodine, adipose and glandular tissue. The x-ray tube voltage was 120 kVp. The energy selective CT data were acquired, and used to generate energy-weighted and material-selective CT images. The energy-weighted and material decomposition CT images were generated using a single CT scan at a fixed x-ray tube voltage. For material decomposition the x-ray spectrum was digitally spilt into low- and high-energy parts and dual-energy subtraction was applied. The x-ray energy weighting resulted in CNR improvement of calcifications and iodine by a factor of 1.40 and 1.63, respectively, as compared to conventional charge integrating CT. The x-ray energy weighting was also applied to low- and high-energy CT projections used for material decomposition. This improved the CNR in images of decomposed calcification and iodine by a factor of 1.57 and 1.46, respectively, as compared to conventional charge integrating CT. Some limitations were observed due to hole trapping in CZT and charge sharing between the detector pixels. First experimental results demonstrate that energy-resolved CT is coming close to its practical applications. Although hole trapping and charge sharing in CZT deteriorates x-ray spectrum and limits CNR improvement with energy weighting and detector count rate, this problem has a feasible solution, which is discussed in this paper and is a matter of ongoing research.
引用
收藏
页码:5595 / 5613
页数:19
相关论文
共 50 条
  • [31] Sparse view Compton scatter tomography with energy resolved data: experimental and simulation results
    Desmal, Abdulla
    Tracey, Brian H.
    Rezaee, Hamideh
    Miller, Eric L.
    Schubert, Jeffrey R.
    Denker, Jeff
    Couture, Aaron
    [J]. ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX) II, 2017, 10187
  • [32] Low-dose exposure energy-resolved X-ray computed tomography using a contrast agent with a high-energy K-edge
    Yamashita, Yoshiki
    Shima, Kazunari
    Kanno, Ikuo
    Ohtaka, Masahiko
    Hashimoto, Makoto
    Ara, Kuniaki
    Onabe, Hideaki
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2014, 51 (01) : 91 - 97
  • [33] Simulation of Energy-Resolved Mass Spectrometry Distributions
    Seffernick, Justin T.
    Turzo, S. M. Bargeen Ala m
    Harvey, Sophie R. .
    Kim, Yongseok
    Somogyi, Arpad
    Marciano, Shir
    Wysocki, Vicki H.
    Lindert, Steffen
    [J]. ANALYTICAL CHEMISTRY, 2022, 94 (29) : 10506 - 10514
  • [34] ENERGY-RESOLVED STUDIES OF PHOTOCHEMISTRY ON SEMICONDUCTOR SURFACES
    YANG, QY
    OSGOOD, RM
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1993, 97 (35): : 8855 - 8863
  • [35] ENERGY-RESOLVED AND ANGLE-RESOLVED DOUBLE PHOTOIONIZATION IN HELIUM
    SCHWARZKOPF, O
    KRASSIG, B
    ELMIGER, J
    SCHMIDT, V
    [J]. PHYSICAL REVIEW LETTERS, 1993, 70 (20) : 3008 - 3011
  • [36] The energy-resolved neutron imaging system, RADEN
    Shinohara, Takenao
    Kai, Tetsuya
    Oikawa, Kenichi
    Nakatani, Takeshi
    Segawa, Mariko
    Hiroi, Kosuke
    Su, Yuhua
    Ooi, Motoki
    Harada, Masahide
    Iikura, Hiroshi
    Hayashida, Hirotoshi
    Parker, Joseph D.
    Matsumoto, Yoshihiro
    Kamiyama, Takashi
    Sato, Hirotaka
    Kiyanagi, Yoshiaki
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (04):
  • [37] A joint reconstruction and lambda tomography regularization technique for energy-resolved x-ray imaging
    Webber, James
    Quinto, Eric Todd
    Miller, Eric L.
    [J]. INVERSE PROBLEMS, 2020, 36 (07)
  • [38] Energy-resolved supercurrent between two superconductors
    Yip, SK
    [J]. PHYSICAL REVIEW B, 1998, 58 (09): : 5803 - 5807
  • [39] THE IONIZATION OF GA+ BY ENERGY-RESOLVED ELECTRONS
    PEART, B
    UNDERWOOD, JRA
    [J]. JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1990, 23 (14) : 2343 - 2347
  • [40] THE IONIZATION OF CA+ BY ENERGY-RESOLVED ELECTRONS
    PEART, B
    UNDERWOOD, JRA
    DOLDER, K
    [J]. JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1989, 22 (17) : 2789 - 2795