Load Frequency Control of an Interconnected Reheat Thermal system using Type-2 fuzzy system including SMES units

被引:64
|
作者
Sudha, K. R. [1 ]
Santhi, R. Vijaya [1 ]
机构
[1] Andhra Univ, Dept Elect Engn, Waltair 530003, Andhra Pradesh, India
关键词
Load frequency control (LFC); Type-2 (T2) fuzzy controller; Generation Rate Constraint (GRC); Boiler Dynamics (BD); Superconducting magnetic energy storage (SMES); AUTOMATIC-GENERATION CONTROL; POWER-SYSTEM; LOGIC;
D O I
10.1016/j.ijepes.2012.06.065
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The transient behavior of many large scale systems is heavily influenced by perturbations and in particular, usually, due to changes in operating points. Load Frequency Control (LFC) in power systems is very important in order to supply reliable electric power with good quality. The goal of LFC is to maintain zero steady state errors for frequency deviations in each control area. Several control strategies, such as classical control, optimal control, suboptimal control, adaptive control, variable structure control etc. have been employed in the past to explore an optimum controller for LFC. In practice LFC systems use simple Proportional Integral (PI) controllers, Proportional Integral Derivative (PID) controllers etc. This paper presents a method based on Type-2 Fuzzy System (T2FS) for Load frequency control (LFC) of power systems including Superconducting magnetic energy storage (SMES) units of a two-area interconnected reheat thermal system. This paper proposes a Type-2 (T2) fuzzy approach for load frequency control of two-area interconnected reheat thermal power system with the consideration of Generation Rate Constraint (CRC). Boiler Dynamics (BD) and SMES. The salient advantage of this controller is its high insensitivity to large load changes and plant parameter variations even in the presence of non-linearities. The proposed method is tested on a two-area power system to illustrate its robust performance with various area load changes. The performance of the Type-2 (T2) fuzzy controller is compared with optimal PID (Khamsum's optimal PID) controller and Fuzzy PI Controller (Type-1 Fuzzy) controller in the presence of CRC, BD and SMES. Simulation results confirm the high robustness of the proposed SMES controller with small power capacity against various disturbances and system uncertainties in comparison with SMES in the previous research. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1383 / 1392
页数:10
相关论文
共 50 条
  • [11] Load Frequency Control of AC Microgrid Interconnected Thermal Power System
    Lal, Deepak Kumar
    Barisal, Ajit Kumar
    [J]. INTERNATIONAL CONFERENCE ON MATERIALS, ALLOYS AND EXPERIMENTAL MECHANICS (ICMAEM-2017), 2017, 225
  • [12] Designing an adaptive type-2 fuzzy logic system load frequency control for a nonlinear time-delay power system
    Sabahi, Kamel
    Ghaemi, Sehraneh
    Badamchizadeh, Mohammadali
    [J]. APPLIED SOFT COMPUTING, 2016, 43 : 97 - 106
  • [13] Automatic generation control with fuzzy logic controllers in the power system including SMES units
    Demiroren, A
    Yesil, E
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2004, 26 (04) : 291 - 305
  • [14] Online adaptive type-2 fuzzy logic control for load frequency of multi-area power system
    Shakibjoo, Ali Dokht
    Moradzadeh, Mohammad
    Moussavi, Seyed Zeinolabedin
    Afrakhte, Hossein
    [J]. JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2019, 37 (01) : 1033 - 1042
  • [15] Fuzzy Self-Tuning Interval Type-2 Control for the Egyptian Power System Load Frequency Controller
    Ghany, M. A. Abdel
    Ghany, A. M. Abdel
    Bensenouci, Ahmed
    Ahmad, M. N. Syed
    Bensenouci, M. A.
    [J]. JOURNAL OF ELECTRICAL SYSTEMS, 2019, 15 (02) : 237 - 248
  • [16] Load Frequency Control of Two Area Interconnected Power System Using Fuzzy Logic Control and PID Controller
    Tur, Mehmet Rida
    Wadi, Mohammed
    Shobole, Abdulfetah
    Ay, Selim
    [J]. 2018 7TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2018, : 1253 - 1258
  • [17] Mobile robot control using type-2 fuzzy logic system
    Phokharatkul, P
    Phaiboon, S
    [J]. 2004 IEEE CONFERENCE ON ROBOTICS, AUTOMATION AND MECHATRONICS, VOLS 1 AND 2, 2004, : 296 - 299
  • [18] Memetic Type-2 Fuzzy System Learning for Load Forecasting
    Leon, Ivan Castro
    Taylor, Philip C.
    [J]. PROCEEDINGS OF THE 2015 CONFERENCE OF THE INTERNATIONAL FUZZY SYSTEMS ASSOCIATION AND THE EUROPEAN SOCIETY FOR FUZZY LOGIC AND TECHNOLOGY, 2015, 89 : 909 - 916
  • [19] Optimized PI plus load-frequency controller using BWNN approach for an interconnected reheat power system with RFB and hydrogen electrolyser units
    Francis, R.
    Chidambaram, I. A.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 67 : 381 - 392
  • [20] Neuro-Fuzzy Computational Technique to Control Load Frequency in Hydro-Thermal Interconnected Power System
    Prakash S.
    Sinha S.K.
    [J]. Journal of The Institution of Engineers (India): Series B, 2015, 96 (3) : 273 - 282