Impact of the Gas Environment on the Electric Arc

被引:0
|
作者
Grogg, Daniel [1 ]
Schrank, Clemens [1 ]
机构
[1] TE Connect, Ind Technol, CH-8810 Horgen, Switzerland
关键词
Electromagnetic relay; atmosphere; electric arc; arc mobility; arc voltage;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The influence of the oxygen concentration on the break arc is observed in a range of 0 to 50 % oxygen in an oxygen-nitrogen mixture under a resistive DC load of 55.5 V and 10 Omega. The arc characteristics are observed by means of oscilloscope traces and high speed camera images showing a clear correlation of the arc motion and the speed of the motion with the oxygen concentration. In contrast, the electrical characteristics change only little over all gases containing oxygen and show a large difference for pure nitrogen. The motion of the arc on AgSnO2 and AgNi 0.15 is influenced in different ways by the higher oxygen concentration. The average distance between cathode spots (arc step) from frame to frame (observed at 483'000 images/s) is lowest for pure nitrogen for both materials. For AgSnO2, the arc step increases with increasing oxygen concentration at low oxygen levels and reaches a maximum step size at 15 to 20 % oxygen. For AgNi 0.15 larger arc steps are observed at 5 % oxygen, decreasing with increasing oxygen concentration over the whole range. These experiments show the importance of oxygen on the arc behavior and, therefore, on the relay behavior.
引用
收藏
页码:125 / 128
页数:4
相关论文
共 50 条
  • [41] Processes of energy exchange between blasted electric arc and surrounding gas in arc heater channel
    Heinz, J
    Senk, J
    Hrabovsky, M
    CZECHOSLOVAK JOURNAL OF PHYSICS, 2002, 52 : 583 - 588
  • [42] Creating a Safe Environment While GAS METAL ARC WELDING
    Detmer, David
    Montez, Phil
    Turner, Rachel
    WELDING JOURNAL, 2023, 102 (06) : 60 - 62
  • [43] IMPACT OF ENVIRONMENT ON CORROSION OF ELECTRIC AND ELECTRONIC DEVICES
    ZUMELZU DELGADO, E
    TAPPI JOURNAL, 1994, 77 (09): : 241 - 243
  • [44] Modeling of the Electric Arc Behavior of the Electric Arc Furnace
    Panoiu, Manuela
    Panoiu, Caius
    Ghiormez, Loredana
    SOFT COMPUTING APPLICATIONS, 2013, 195 : 261 - 271
  • [45] The Analysis of Electric Arc Impact on Distance Relay Measurement Error
    Belcevic, Nenad
    Stojanovic, Zoran
    2018 INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (INDEL 2018), 2018,
  • [46] Electric, Hybrid Electric and Combustion Engine Driven Cars and their Impact on Environment
    Zdenek, Cerovsky
    Pavel, Mindl
    PROCEEDINGS OF THE 2011-14TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE 2011), 2011,
  • [47] FUZZY CONTROL OF AN ELECTRIC ARC FURNACE OFF-GAS PROCESS
    Hasannia, A.
    Esteki, H.
    IMECE 2008: HEAT TRANSFER, FLUID FLOWS, AND THERMAL SYSTEMS, VOL 10, PTS A-C, 2009, : 471 - 477
  • [48] INITIAL SECTION OF AN ELECTRIC-ARC IN A GAS-FLOW (SURVEY)
    PAKHOMOV, EP
    HIGH TEMPERATURE, 1982, 20 (01) : 149 - 164
  • [49] SOME EFFECTS NOTICED WHEN STUDYING AN ELECTRIC ARC IN A GAS FLOW
    BARANOV, VY
    HIGH TEMPERATURE, 1966, 4 (05) : 585 - &
  • [50] Modelling of electric arc furnace off-gas removal system
    Timoshenko, N.
    Semko, A.
    Timoshenko, S.
    IRONMAKING & STEELMAKING, 2014, 41 (04) : 257 - 261