Monte Carlo-based statistical SPECT reconstruction: Influence of number of photon tracks

被引:19
|
作者
de Wit, TC
Xiao, JB
Beekman, FJ
机构
[1] Univ Utrecht, Med Ctr, Dept Nucl Med, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[2] Univ Utrecht, Med Ctr, Rudolf Magnus Inst Neurosci, Dept Pharmacol & Anat, NL-3584 CX Utrecht, Netherlands
关键词
cardiac imaging; image reconstruction; Monte Carlo simulation; scatter; single photon emission computed tomography;
D O I
10.1109/TNS.2005.858220
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Quantitative accuracy of single-photon-emission computed,tomography (SPECT) images is highly dependent on the photon scatter model used for image reconstruction. Monte Carlo simulation (MCS) is the most general tool for accurate modeling and correction of scatter, but calculations are notoriously slow. Recently, we proposed an efficient strategy for fully three-dimensional (3-D) statistical reconstruction using highly accelerated MCS as a forward projector. We use convolution forced detection (CFD) which accelerates convergence of reprojection by about two orders of magnitude. Here, we investigate how many photon histories during CFD-based MCS need to be calculated to: i) ensure that the noise in the reconstructed image does not increase markedly because of the stochastic nature of MCS reprojections; and ii) to determine the reconstruction time needed. To this end, phantom studies representing Tc-99m cardiac perfusion SPECT, were carried out. We generated reconstructions with different numbers of photon histories during MCS forward projection. Images and profiles were compared for reconstructions with a different number of photon tracks, for reconstructions from different noise realizations using a repeat measurement and for reconstructions with different random seeds for MCS reprojection. We found that 10(5) photon histories per subset is sufficient to produce accurate images; more photons do not show visible improvement. This amount of photons corresponds to a typical reconstruction time below 5 min for a 64(3) volume image on a dual-cpu PC (2.66 GHz), which is sufficiently short to apply such highly accurate reconstruction in clinical routine.
引用
收藏
页码:1365 / 1369
页数:5
相关论文
共 50 条
  • [21] Reporting and analyzing statistical uncertainties in Monte Carlo-based treatment planning
    Chetty, Indrin J.
    Rosu, Mihaela
    Kessler, Marc L.
    Fraass, Benedick A.
    Ten Haken, Randall K.
    Kong, Feng-Ming
    McShan, Daniel L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (04): : 1249 - 1259
  • [22] A New Sampling Technique for Monte Carlo-based Statistical Circuit Analysis
    Mahmoudi, Hiwa
    Zimmermann, Horst
    [J]. PROCEEDINGS OF THE 2017 DESIGN, AUTOMATION & TEST IN EUROPE CONFERENCE & EXHIBITION (DATE), 2017, : 1277 - 1280
  • [23] Efficient Monte Carlo based reconstruction for general quantitative SPECT
    Beekman, FJ
    de Jong, HWAM
    van Geloven, S
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1864 - 1868
  • [24] Absolute quantification in dopaminergic neurotransmission SPECT using a Monte Carlo-based scatter correction and fully 3-dimensional reconstruction
    Cot, A
    Falcón, C
    Crespo, C
    Sempau, J
    Pareto, D
    Bullich, S
    Lomeña, F
    Calviño, F
    Pavía, J
    Ros, D
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (09) : 1497 - 1504
  • [25] Compensation for Patient and Detector Scatter and Crosstalk Contamination in 111In SPECT Using Fast Monte Carlo-based Iterative Reconstruction
    Ouyang, Jinsong
    El Fakhri, Georges
    Zimmerman, Robert E.
    Moore, Stephen C.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2851 - 2853
  • [26] Verification of a Monte Carlo-Based Source Model for a Varian 10 MV Photon Beam
    Davidson, S.
    Cui, J.
    Deasy, J.
    Ibbott, G.
    Followill, D.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [27] Monte Carlo-based energy response studies of diode dosimeters in radiotherapy photon beams
    Arun C.
    Selvam T.P.
    Dinkar V.
    Munshi P.
    Kalra M.S.
    [J]. Radiological Physics and Technology, 2013, 6 (1) : 151 - 156
  • [28] Monte Carlo-based revised values of dose rate constants at discrete photon energies
    Selvam, T. Palani
    Shrivastava, Vandana
    Chourasiya, Ghanashyam
    Babu, D. Appala Raju
    [J]. JOURNAL OF MEDICAL PHYSICS, 2014, 39 (01) : 4 - 9
  • [29] Monte Carlo-based tail exponent estimator
    Barunik, Jozef
    Vacha, Lukas
    [J]. PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2010, 389 (21) : 4863 - 4874
  • [30] Monte Carlo-based food irradiation simulator
    Kim, J
    Moreira, RG
    Rivadeneira, R
    Castell-Perez, ME
    [J]. JOURNAL OF FOOD PROCESS ENGINEERING, 2006, 29 (01) : 72 - 88