Monte Carlo-based statistical SPECT reconstruction: Influence of number of photon tracks

被引:19
|
作者
de Wit, TC
Xiao, JB
Beekman, FJ
机构
[1] Univ Utrecht, Med Ctr, Dept Nucl Med, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
[2] Univ Utrecht, Med Ctr, Rudolf Magnus Inst Neurosci, Dept Pharmacol & Anat, NL-3584 CX Utrecht, Netherlands
关键词
cardiac imaging; image reconstruction; Monte Carlo simulation; scatter; single photon emission computed tomography;
D O I
10.1109/TNS.2005.858220
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Quantitative accuracy of single-photon-emission computed,tomography (SPECT) images is highly dependent on the photon scatter model used for image reconstruction. Monte Carlo simulation (MCS) is the most general tool for accurate modeling and correction of scatter, but calculations are notoriously slow. Recently, we proposed an efficient strategy for fully three-dimensional (3-D) statistical reconstruction using highly accelerated MCS as a forward projector. We use convolution forced detection (CFD) which accelerates convergence of reprojection by about two orders of magnitude. Here, we investigate how many photon histories during CFD-based MCS need to be calculated to: i) ensure that the noise in the reconstructed image does not increase markedly because of the stochastic nature of MCS reprojections; and ii) to determine the reconstruction time needed. To this end, phantom studies representing Tc-99m cardiac perfusion SPECT, were carried out. We generated reconstructions with different numbers of photon histories during MCS forward projection. Images and profiles were compared for reconstructions with a different number of photon tracks, for reconstructions from different noise realizations using a repeat measurement and for reconstructions with different random seeds for MCS reprojection. We found that 10(5) photon histories per subset is sufficient to produce accurate images; more photons do not show visible improvement. This amount of photons corresponds to a typical reconstruction time below 5 min for a 64(3) volume image on a dual-cpu PC (2.66 GHz), which is sufficiently short to apply such highly accurate reconstruction in clinical routine.
引用
收藏
页码:1365 / 1369
页数:5
相关论文
共 50 条
  • [1] Monte-Carlo based statistical SPECT reconstruction: Influence of number of photon tracks
    de Wit, TC
    Xiao, JB
    Bokulic, T
    Beekman, FJ
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3018 - 3021
  • [2] Monte Carlo-based SPECT reconstruction within the SIMIND framework
    Gustafsson, Johan
    Brolin, Gustav
    Ljungberg, Michael
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (24):
  • [3] Quantitative Monte Carlo-Based 90Y SPECT Reconstruction
    Elschot, Mattijs
    Lam, Marnix G. E. H.
    van den Bosch, Maurice A. A. J.
    Viergever, Max A.
    de Jong, Hugo W. A. M.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (09) : 1557 - 1563
  • [4] Quantitative Monte Carlo-based holmium-166 SPECT reconstruction
    Elschot, Mattijs
    Smits, Maarten L. J.
    Nijsen, Johannes F. W.
    Lam, Marnix G. E. H.
    Zonnenberg, Bernard A.
    van den Bosch, Maurice A. A. J.
    Viergever, Max A.
    de Jong, Hugo W. A. M.
    [J]. MEDICAL PHYSICS, 2013, 40 (11)
  • [5] Implementation of GPU accelerated SPECT reconstruction with Monte Carlo-based scatter correction
    Tobias Bexelius
    Antti Sohlberg
    [J]. Annals of Nuclear Medicine, 2018, 32 : 337 - 347
  • [6] Implementation of GPU accelerated SPECT reconstruction with Monte Carlo-based scatter correction
    Bexelius, Tobias
    Sohlberg, Antti
    [J]. ANNALS OF NUCLEAR MEDICINE, 2018, 32 (05) : 337 - 347
  • [7] Modelling Aspects for Quantitative Monte Carlo-based SPECT Reconstruction of Radium-223
    Gustafsson, J.
    Minguez, P.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S229 - S230
  • [8] Acceleration of Monte Carlo-based scatter compensation for cardiac SPECT
    Sohlberg, A.
    Watabe, H.
    Iida, H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (14): : N277 - N285
  • [9] A parallel approach for Monte Carlo-based photon propagation simulation
    Rusu, Ionela
    Pentiuc, Stefan-Gheorghe
    Ungurean, Ioan
    Craciun, Elena-Gina
    [J]. 2012 5TH ROMANIA TIER 2 FEDERATION GRID, CLOUD & HIGH PERFORMANCE COMPUTING SCIENCE (RO-LCG), 2012, : 78 - 81
  • [10] Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation
    Beekman, FJ
    de Jong, HWAM
    van Geloven, S
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (08) : 867 - 877