Biomechanical evaluation of anterior spinal instrumentation systems for scoliosis -: In vitro fatigue simulation

被引:79
|
作者
Shimamoto, N
Kotani, Y
Shono, Y
Kadoya, K
Abumi, K
Kaneda, K
Minami, A
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Orthopaed Surg, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Bibai Labor Accident Hosp, Dept Orthopaed Surg, Bibai, Japan
关键词
biomechanics; thoracolumbar spine; bone-screw interface; anterior instrumentation; scoliosis;
D O I
10.1097/00007632-200112150-00013
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A biomechanical study was designed to assess the bone-screw interface fixation strength among five anterior spinal instrumentation systems for scoliosis before and after a fatigue simulation. Objectives. The objectives of the current study were twofold: 1) evaluate the static (initial) strength at the bone-screw interface and 2) evaluate dynamic (post fatigue) strength of the bone-screw interface after a fatigue simulation to investigate a possible mechanism for postoperative loss of correction. Summary of Background Data. Although the recent advancement of anterior instrumentation for scoliosis has permitted shorter fusion segments and improved surgical correction, the loss of correction over the instrumented segments still has been reported in one-rod systems. Little is known about the mechanism for loss of correction. Methods. Twenty-five fresh-frozen calf spines (T6-L6) were used. A total of five instrumentation systems included the following: Anterior ISOLA (ISOLA), Bad Wildungen Metz (BWM), Texas Scottish Rite Hospital system (TSRH), Cotrel-Dubousset Hoph (CDH), and Kaneda Anterior Scoliosis System (KASS). Screw pullout and rotational tests in the sagittal plane using a single vertebra were performed to investigate bone-screw interface fixation strength before and after a fatigue simulation. To simulate cyclic loading that the spine could undergo in vivo, a fatigue simulation using compressive-flexion loading up to 24,000 cycles was carried out. Results. Mean maximum tensile pullout force decreased in the following order: KASS > CDH > BWM > TSRH > ISOLA (F = 29 91, P < 0.0001). KASS blunt tip screw was 26% stronger in pullout force than KASS sharp tip screw (P < 0.05). The one-rod system demonstrated a positive correlation between pullout force and both bone mineral density and screw insertional torque, For fatigue analysis the rotational strength at the most cephalad and caudal segments significantly decreased after a fatigue simulation in the one-rod system (P < 0.05). The two-rod system showed no significant decrease after a fatigue simulation. Conclusions. Simulating the cyclic loading to the construct, screw loosening at the bone-screw interface was produced in the one-rod system, This screw loosening may elucidate one mechanism for loss of correction in the one-rod system. The two-rod system may have the potential to minimize the risk of loss of correction.
引用
收藏
页码:2701 / 2708
页数:8
相关论文
共 50 条
  • [31] Prospective evaluation of 50 consecutive scoliosis patients surgically treated with thoracoscopic anterior instrumentation
    Newton, PO
    Parent, S
    Marks, M
    Pawelek, J
    [J]. SPINE, 2005, 30 (17) : S100 - S109
  • [32] Analysis of screw placement relative to the aorta and spinal canal following anterior instrumentation for thoracic idiopathic scoliosis
    Sucato, DJ
    Kassab, F
    Dempsey, M
    [J]. SPINE, 2004, 29 (05) : 554 - 559
  • [33] The effect of continued posterior spinal growth on sagittal contour in patients treated by anterior instrumentation for idiopathic scoliosis
    D'Andrea, LP
    Betz, RR
    Lenke, LG
    Harms, J
    Clements, DH
    Lowe, TG
    [J]. SPINE, 2000, 25 (07) : 813 - 817
  • [34] A prospective comparison of thoracoscopic vs open anterior instrumentation and spinal fusion for idiopathic thoracic scoliosis in children
    Grewal, H
    Betz, RR
    D'Andrea, LP
    Clements, DH
    Porter, ST
    [J]. JOURNAL OF PEDIATRIC SURGERY, 2005, 40 (01) : 153 - 156
  • [35] A comparative biomechanical analysis of spinal instability and instrumentation of the cervicothoracic junction - An in vitro human cadaveric model
    Prybis, Brad G.
    Tortolani, Paul J.
    Hu, Nianbin
    Zorn, Candace M.
    McAfee, Paul C.
    Cunningham, Bryan W.
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (03): : 233 - 238
  • [36] ENHANCED SPINO-PELVIC FIXATION FOR SEGMENTAL SPINAL INSTRUMENTATION - A PRELIMINARY BIOMECHANICAL EVALUATION
    THOMAS, KA
    KING, AGS
    ZEMBO, MM
    SOLOMONOW, M
    SUMMERSGILL, LE
    DABEZIES, EJ
    [J]. ORTHOPEDICS, 1994, 17 (06) : 527 - 537
  • [37] Biomechanical analysis of spino-pelvic parameters in adolescent idiopathic scoliosis after spinal instrumentation and fusion: A case study
    Pasha, Saba
    Aubin, Carl-Eric
    Labelle, Hubert
    Parent, Stefan
    Mac-Thiong, Jean-Marc
    [J]. RESEARCH INTO SPINAL DEFORMITIES 8, 2012, 176 : 125 - 128
  • [38] Biomechanical Simulation of Stresses and Strains Exerted on the Spinal Cord and Nerves During Scoliosis Correction Maneuvers
    Henao J.
    Labelle H.
    Arnoux P.-J.
    Aubin C.-É.
    [J]. Spine Deformity, 2018, 6 (1) : 12 - 19
  • [39] Biomechanical analysis of rod contouring in posterior spinal instrumentation and fusion for 3D correction of adolescent idiopathic scoliosis
    Marine Gay
    Xiaoyu Wang
    Todd Ritzman
    Lorena Floccari
    Richard M. Schwend
    Carl-Eric Aubin
    [J]. Spine Deformity, 2023, 11 : 1309 - 1316
  • [40] Biomechanical analysis of rod contouring in posterior spinal instrumentation and fusion for 3D correction of adolescent idiopathic scoliosis
    Gay, Marine
    Wang, Xiaoyu
    Ritzman, Todd
    Floccari, Lorena
    Schwend, Richard M.
    Aubin, Carl-Eric
    [J]. SPINE DEFORMITY, 2023, 11 (06) : 1309 - 1316