Comparison of amino acid derivatization reagents for LC-ESI-MS analysis. Introducing a novel phosphazene-based derivatization reagent

被引:43
|
作者
Rebane, Riin [1 ]
Oldekop, Maarja-Liisa [1 ]
Herodes, Koit [1 ]
机构
[1] Univ Tartu, Inst Chem, EE-50411 Tartu, Estonia
关键词
Amino acids; Derivatization reagents; LC-ESI-MS; PRECOLUMN DERIVATIZATION; MASS-SPECTROMETRY; 9-FLUORENYLMETHYL CHLOROFORMATE; BIOGENIC-AMINES; ENHANCEMENT; QUANTIFICATION; OPTIMIZATION; ION;
D O I
10.1016/j.jchromb.2012.07.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Amino acid analysis with high performance liquid chromatography with electrospray ionization mass spectrometry (LC-ESI-MS) is an emerging method. For more sensitive analysis, derivatization is used and next to commercially available derivatization reagents such as dansyl chloride (DNS), 9-fluorenylmethyl chloroformate (FMOC-CI) and diethyl ethoxymethylenemalonate (DEEMM), new derivatization reagents are designed specially for LC-ESI-MS, like p-N,N,N-trimethylammonioanilyl N'-hydroxysuccinimidyl carbamate iodide (TAHS) which provides very low limits of detection. In this work, a novel phosphazene based derivatization reagent (FOSF) that provides comparable limits of quantitation (LoQ) to TAHS is introduced. Moreover, a thorough comparison between FOSF, TANS, DNS, FMOC-CI and DEEMM is carried out for 7 different amino acids - Arg, Asp, Gly, beta-Ala. Pro, Trp and Phe. This is a first time that thorough comparison is carried out on the same instrument for amino acid derivatization reagents. Results on the same instrument for five amino acid derivatization reagents show that novel reagents are sensitive with LoQ values around 80 fmol but have disadvantages such as problematic chromatographic separation. Next to novel reagents. DEEMM offers very good LoQ-s (average of 150 fmol) and wide dynamic linear range. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 45 条
  • [21] Derivatization of carboxylic acids with 4-APEBA for detection by positive-ion LC-ESI-MS(/MS) applied for the analysis of prostanoids and NSAID in urine
    Kretschmer, A.
    Giera, M.
    Wijtmans, M.
    de Vries, L.
    Lingeman, H.
    Irth, H.
    Niessen, W. M. A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (17-18): : 1393 - 1401
  • [22] Determination of total tiopronin in human plasma by LC-ESI-MS using tris (2-carboxy-ethyl) phosphine as reducing reagent and methyl acrylate as derivatization reagent for the thiol group
    Liu, Jianfang
    Wu, Honghai
    Hou, Yanning
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (01): : 153 - 157
  • [23] Profiling of chiral and achiral carboxylic acid metabolomics: synthesis and evaluation of triazine-type chiral derivatization reagents for carboxylic acids by LC-ESI-MS/MS and the application to saliva of healthy volunteers and diabetic patients
    Takahiro Takayama
    Tomohiro Kuwabara
    Toshio Maeda
    Ichiro Noge
    Yutaka Kitagawa
    Koichi Inoue
    Kenichiro Todoroki
    Jun Zhe Min
    Toshimasa Toyo’oka
    Analytical and Bioanalytical Chemistry, 2015, 407 : 1003 - 1014
  • [24] Relative quantification of enantiomers of chiral amines by high-throughput LC-ESI-MS/MS using isotopic variants of light and heavy L-pyroglutamic acids as the derivatization reagents
    Mochizuki, Toshiki
    Taniguchi, Sayuri
    Tsutsui, Haruhito
    Min, Jun Zhe
    Inoue, Koichi
    Todoroki, Kenichiro
    Toyo'oka, Toshimasa
    ANALYTICA CHIMICA ACTA, 2013, 773 : 76 - 82
  • [25] Profiling of chiral and achiral carboxylic acid metabolomics: synthesis and evaluation of triazine-type chiral derivatization reagents for carboxylic acids by LC-ESI-MS/MS and the application to saliva of healthy volunteers and diabetic patients
    Takayama, Takahiro
    Kuwabara, Tomohiro
    Maeda, Toshio
    Noge, Ichiro
    Kitagawa, Yutaka
    Inoue, Koichi
    Todoroki, Kenichiro
    Min, Jun Zhe
    Toyo'oka, Toshimasa
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (03) : 1003 - 1014
  • [26] Enhancing LC/ESI-MS/MS Throughput for Plasma Bile Acid Assay by Derivatization-based Sample-Multiplexing
    Jo, Akihiro
    Koyagi, Sae
    Hobo, Wataru
    Otani, Saori
    Ogawa, Shoujiro
    Higashi, Tatsuya
    ANALYTICAL SCIENCES, 2020, 36 (09) : 1099 - 1104
  • [27] Application of 4-Diethylaminobenzoic Acid N-Succinimidyl Ester and Its Deuterated Isotopologue as Derivatization Reagents to Quantitative Analysis of γ-Aminobutyric Acid in Serum by LC/ESI-MS/MS
    Mikami, Yohei
    Aizawa, Mizuo
    Toda, Ryoko
    Ogawa, Shoujiro
    Nishimoto-kusunose, Shoichi
    Ishige, Takayuki
    Higashi, Tatsuya
    CHROMATOGRAPHY, 2022, 43 (02) : 53 - 58
  • [28] Isotope-coded ESI-enhancing derivatization reagents for differential analysis, quantification and profiling of metabolites in biological samples by LC/MS: A review
    Higashi, Tatsuya
    Ogawa, Shoujiro
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 130 : 181 - 193
  • [29] Isotope-coded derivatization based LC/ESI-MS/MS methods using a pair of novel reagents for quantification of hydroxycinnamic acids and hydroxybenzoic acids in fermented brown rice product
    Ogawa, Shoujiro
    Takafuji, Kiriko
    Tsubuku, Sumi
    Horie, Yukiko
    Ikegawa, Shigeo
    Higashi, Tatsuya
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 142 : 162 - 170
  • [30] Comparison of derivatization and chromatographic methods for GC-MS analysis of amino acid enantiomers in physiological samples
    Waldhier, Magdalena C.
    Dettmer, Katja
    Gruber, Michael A.
    Oefner, Peter J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (15-16): : 1103 - 1112