Design of a rotational ultrasound guided diffuse optical tomography system for whole breast imaging

被引:0
|
作者
Deng, Zixin [1 ,2 ]
Lin, Yuting [1 ,2 ]
Ikemura, Kenji [1 ,2 ]
Tseng, Michael [1 ,2 ]
Chan, Yu-Wen [1 ,2 ]
Gulsen, Gultekin [1 ,2 ]
机构
[1] Univ Calif Irvine, Tu & Yuen Ctr Funct Oncoimaging, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2013 | 2013年 / 8581卷
关键词
Diffuse optical imaging; diffuse optical tomography (DOT); ultrasound; a priori; ultrasound guided DOT; DOT whole breast imaging; BENIGN; TUMORS; MRI; US; DIFFERENTIATION; SPECTROSCOPY; LESIONS; MASSES;
D O I
10.1117/12.2005805
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This study focuses on a multimodal imaging technique that integrates both structural and functional information using a priori ultrasound (US) information to assist near-infrared (NIR) diffuse optical tomography (DOT). Up to date, hand-held systems that integrates DOT and US have been demonstrated. Our system is designed to be fully-automated and non-contact. Our aim is to build an interface, in which the optical source and detector fibers will rotate around the breast together with the US transducer. However, in this study we built a prototype system, which rotated the phantom and kept the transducers stationary for simplicity. Simulation and experimental studies were performed using a variety of source-detector configurations. The reconstruction results were compared with and without US a priori information. To collect the a priori US information, the multi-modality agar phantom was rotated 360 degrees using a computer controlled rotational stage. The multi-modality phantom had an inclusion that had both optical absorption and US contrast. 360 US images were collected in 1 degrees increments covering the entire phantom volume. The DOT data was also collected while the phantom is rotated with particular source-detector configurations. These results have shown that when the detectors were pi /8 apart, and the phantom is rotating at pi /16 increments with a total of 32 views provide the optimum image reconstruction. As expected, US a priori information further improved the quantification accuracy.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] An optimized engineering design of imaging probe for time-resolved diffuse optical tomography system
    Chen, Ling
    Hasnain, Ali
    Chen, Nanguang
    OPTICAL SENSORS AND BIOPHOTONICS III, 2011, 8311
  • [32] An optimized engineering design of imaging probe for time-resolved diffuse optical tomography system
    Chen, Ling
    Hasnain, Ali
    Chen, Nanguang
    2011 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE AND EXHIBITION (ACP), 2012,
  • [33] COMPARISON OF DIFFUSE OPTICAL TOMOGRAPHY, ULTRASOUND ELASTOGRAPHY AND MAMMOGRAPHY IN THE DIAGNOSIS OF BREAST TUMORS
    Zhang, Haixian
    Qin, Dongjing
    Yang, Zhi
    Wang, Kun
    Sun, Fang
    Li, Baowei
    Cui, Guanghe
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (01): : 1 - 10
  • [34] An ultrasound-guided fluorescence tomography system: design and specification
    DSouza, Alisha V.
    Flynn, Brendan P.
    Kanick, Stephen C.
    Torosean, Sason
    Davis, Scott C.
    Maytin, Edward V.
    Hasan, Tayyaba
    Pogue, Brian W.
    OPTICAL METHODS FOR TUMOR TREATMENT AND DETECTION: MECHANISMS AND TECHNIQUES IN PHOTODYNAMIC THERAPY XXII, 2013, 8568
  • [35] Diffuse optical imaging of the whole head
    Franceschini, Maria Angela
    Joseph, Danny K.
    Huppert, Theodore J.
    Diamond, Solomon G.
    Boas, David A.
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (05)
  • [36] Comparison of diffuse optical tomography human breast with whole-body and breast-only positron emission tomography
    Konecky, Soren D.
    Choe, Regine
    Corlu, Alper
    Lee, Kijoon
    Wiener, Rony
    Srinivas, Shyarn M.
    Saffer, Janet R.
    Freifelder, Richard
    Karp, Joel S.
    Haflioui, Nassirn
    Azar, Fred
    Yodh, Arjun G.
    MEDICAL PHYSICS, 2008, 35 (02) : 446 - 455
  • [37] Effect of vascular haemoglobin concentrations on ultrasound-guided diffuse optical tomography in differentiating benign from malignant breast lesions
    Ning Lv
    Ni He
    Yaopan Wu
    Chuanmiao Xie
    Yue Wang
    Yanan Kong
    Weidong Wei
    Peihong Wu
    European Radiology, 2014, 24 : 2848 - 2856
  • [38] Effect of vascular haemoglobin concentrations on ultrasound-guided diffuse optical tomography in differentiating benign from malignant breast lesions
    Lv, Ning
    He, Ni
    Wu, Yaopan
    Xie, Chuanmiao
    Wang, Yue
    Kong, Yanan
    Wei, Weidong
    Wu, Peihong
    EUROPEAN RADIOLOGY, 2014, 24 (11) : 2848 - 2856
  • [39] Imaging the body with diffuse optical tomography
    Boas, DA
    Brooks, DH
    Miller, EL
    DiMarzio, CA
    Kilmer, M
    Gaudette, RJ
    Zhang, Q
    IEEE SIGNAL PROCESSING MAGAZINE, 2001, 18 (06) : 57 - 75
  • [40] Diffuse optical tomography guided quantitative fluorescence molecular tomography
    Tan, Yiyong
    Jiang, Huabei
    APPLIED OPTICS, 2008, 47 (12) : 2011 - 2016