Seismic Evaluation of Repaired and Retrofitted Circular Bridge Piers of Low-Strength Concrete

被引:6
|
作者
Khan, Qaiser-Uz-Zaman [1 ]
Tahir, M. Fiaz [1 ]
Ahmad, Afaq [1 ]
Iqbal, M. [1 ]
机构
[1] Univ Engn & Technol, Dept Civil Engn, Taxila, Pakistan
关键词
Piers; Carbon fiber-reinforced polymers; Cyclic loading; Energy dissipation; CFRP SHEETS; COLUMNS; PERFORMANCE; BEHAVIOR;
D O I
10.1007/s13369-015-1769-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
An experimental investigation was carried out to study the effect of retrofitting on change in dynamic properties of 1/4 scaled damaged and undamaged bridge piers of low-strength concrete. Response of three bridge piers, subjected to cyclic lateral loads and free vibration tests under constant axial loading, was evaluated. One of the piers was tested twice: firstly, it was tested up to damaged state, and then it was repaired with single layer of carbon fiber-reinforced polymer (CFRP). This repaired column was then subjected to the same type of loading as the original one. Third pier was retrofitted in undamaged state with single layer of CFRP. It was observed that ductility of retrofitted column at 2% drift level was 39% higher than that of original column. However, ductility of repaired column was improved to original level. Cumulative energy dissipation capacity of retrofitted column was also improved up to 39.38%, whereas energy dissipation capacity of damaged retrofitted was recovered to original state. After subsequent cycles, improvement in energy dissipation capacity was 25.8 and 18% in retrofitted and repaired columns, respectively.
引用
收藏
页码:3057 / 3066
页数:10
相关论文
共 50 条
  • [21] Seismic collapse assessment of non-seismically designed circular RC bridge piers retrofitted with FRP composites
    Parghi, Anant
    Alam, M. Shahria
    [J]. COMPOSITE STRUCTURES, 2017, 160 : 901 - 916
  • [22] Seismic Performance of BFRP-Reinforced Low-Strength Concrete Circular Columns with High Axial Compression Ratio
    Huang J.
    Zhu D.
    Gao P.
    Zhou A.
    Dai L.
    [J]. Gao, Peng (penggao@hfut.edu.cn), 2020, Tongji University (23): : 1366 - 1373
  • [23] Compressive performance of square and low-strength concrete columns retrofitted with externally-bonded CFRP
    Carrillo, Julian
    Valencia-Mina, William
    Bojorquez, Eden
    [J]. MATERIALS TODAY COMMUNICATIONS, 2020, 23
  • [24] Analytical approach for the earthquake performance evaluation of repaired/retrofitted RC bridge piers using time-dependent element
    Lee, Do Hyung
    Kim, Dookie
    Lee, Kihak
    [J]. NONLINEAR DYNAMICS, 2009, 56 (04) : 463 - 482
  • [25] Analytical approach for the earthquake performance evaluation of repaired/retrofitted RC bridge piers using time-dependent element
    Do Hyung Lee
    Dookie Kim
    Kihak Lee
    [J]. Nonlinear Dynamics, 2009, 56 : 463 - 482
  • [26] Seismic performance of retrofitted reinforced concrete bridge pier
    Schoettler, MJ
    Restrepo, JI
    Seible, F
    Matsuda, E
    [J]. ACI STRUCTURAL JOURNAL, 2005, 102 (06) : 849 - 859
  • [27] Evaluation of seismic vulnerability of reinforced concrete circular hollow high-piers
    Zhou, Chang-Dong
    Chen, Jing
    Zeng, Xu-Lang
    Liu, Bin
    [J]. Journal of Railway Engineering Society, 2014, 31 (11) : 65 - 71
  • [28] Seismic test and calculation method for concrete bridge piers confined by fabricated circular steel tubes
    Zhijing O.
    Jianhuang Y.
    Jie Y.
    Shangshun L.
    [J]. Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2023, 56 (01): : 77 - 89
  • [29] Seismic performances of steel reinforced concrete bridge piers
    Deng, Jiangdong
    Liu, Airong
    Yu, Qicai
    Peng, Guoxing
    [J]. STEEL AND COMPOSITE STRUCTURES, 2016, 21 (03): : 661 - 677
  • [30] Seismic performance of reinforced corroded concrete bridge piers
    Fang, C. Q.
    Yuan, Z. J.
    Zhang, J. M.
    Zhu, J.
    [J]. BRIDGE MAINTENANCE, SAFETY, MANAGEMENT AND LIFE EXTENSION, 2014, : 253 - 260