3D free-breathing cardiac magnetic resonance fingerprinting

被引:43
|
作者
Cruz, Gastao [1 ]
Jaubert, Olivier [1 ]
Qi, Haikun [1 ]
Bustin, Aurelien [1 ]
Milotta, Giorgia [1 ]
Schneider, Torben [2 ]
Koken, Peter [3 ]
Doneva, Mariya [3 ]
Botnar, Rene M. [1 ,4 ]
Prieto, Claudia [1 ,4 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[2] Philips Healthcare, Guildford, England
[3] Philips Res Europe, Hamburg, Germany
[4] Pontificia Univ Catolica Chile, Escuela Ingn, Santiago, Chile
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
3D whole heart; low rank; MR fingerprinting; myocardial tissue characterization; quantitative cardiac MRI; T(1)map; T(2)map; INVERSION-RECOVERY; MOTION CORRECTION; SATURATION RECOVERY; MYOCARDIAL T-1; RECONSTRUCTION; QUANTIFICATION; HEART; MRI; RESOLUTION; MOLLI;
D O I
10.1002/nbm.4370
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose To develop a novel respiratory motion compensated three-dimensional (3D) cardiac magnetic resonance fingerprinting (cMRF) approach for whole-heart myocardialT(1)andT(2)mapping from a free-breathing scan. Methods Two-dimensional (2D) cMRF has been recently proposed for simultaneous, co-registeredT(1)andT(2)mapping from a breath-hold scan; however, coverage is limited. Here we propose a novel respiratory motion compensated 3D cMRF approach for whole-heart myocardialT(1)andT(2)tissue characterization from a free-breathing scan. Variable inversion recovery andT(2)preparation modules are used for parametric encoding, respiratory bellows driven localized autofocus is proposed for beat-to-beat translation motion correction and a subspace regularized reconstruction is employed to accelerate the scan. The proposed 3D cMRF approach was evaluated in a standardizedT(1)/T(2)phantom in comparison with reference spin echo values and in 10 healthy subjects in comparison with standard 2D MOLLI, SASHA andT(2)-GraSE mapping techniques at 1.5 T. Results 3D cMRFT(1)andT(2)measurements were generally in good agreement with reference spin echo values in the phantom experiments, with relative errors of 2.9% and 3.8% forT(1)andT(2)(T-2< 100 ms), respectively. in vivo left ventricle (LV) myocardialT(1)values were 1054 +/- 19 ms for MOLLI, 1146 +/- 20 ms for SASHA and 1093 +/- 24 ms for the proposed 3D cMRF; correspondingT(2)values were 51.8 +/- 1.6 ms for T2-GraSE and 44.6 +/- 2.0 ms for 3D cMRF. LV coefficients of variation were 7.6 +/- 1.6% for MOLLI, 12.1 +/- 2.7% for SASHA and 5.8 +/- 0.8% for 3D cMRFT(1), and 10.5 +/- 1.4% for T2-GraSE and 11.7 +/- 1.6% for 3D cMRFT(2). Conclusion The proposed 3D cMRF can provide whole-heart, simultaneous and co-registeredT(1)andT(2)maps with accuracy and precision comparable to those of clinical standards in a single free-breathing scan of about 7 min.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] A free-breathing non-contrast-enhanced pulmonary magnetic resonance angiography at 3 Tesla
    Yang Jian
    Wang Wei
    Wang Ya-rong
    Niu Gang
    Jin Chen-wang
    Wu Ed Xuekui
    CHINESE MEDICAL JOURNAL, 2009, 122 (18) : 2111 - 2116
  • [32] Free-breathing radial magnetic resonance elastography of the liver in children at 3 T: a pilot study
    Kafali, Sevgi Gokce
    Armstrong, Tess
    Shih, Shu-Fu
    Kim, Grace J.
    Holtrop, Joseph L.
    Venick, Robert S.
    Ghahremani, Shahnaz
    Bolster, Bradley D., Jr.
    Hillenbrand, Claudia M.
    Calkins, Kara L.
    Wu, Holden H.
    PEDIATRIC RADIOLOGY, 2022, 52 (07) : 1314 - 1325
  • [33] Respiratory and Cardiac Self-Gated Free-Breathing Cardiac CINE Imaging With Multiecho 3D Hybrid Radial SSFP Acquisition
    Liu, Jing
    Spincemaille, Pascal
    Codella, Noel C. F.
    Nguyen, Thanh D.
    Prince, Martin R.
    Wang, Yi
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (05) : 1230 - 1237
  • [34] Distortionless, free-breathing, and respiratory resolved 3D diffusion weighted imaging of the abdomen
    Lee, Philip K.
    Zhou, Xuetong
    Wang, Nan
    Syed, Ali B.
    Brunsing, Ryan L.
    Vasanawala, Shreyas S.
    Hargreaves, Brian A.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (02) : 586 - 604
  • [35] Free-breathing 3D cardiac T-1 mapping with transmit B-1 correction at 3T
    Han, Paul Kyu
    Marin, Thibault
    Djebra, Yanis
    Landes, Vanessa
    Zhuo, Yue
    El Fakhri, Georges
    Ma, Chao
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 1832 - 1845
  • [36] 2128 Free-breathing steady-state free precession 3D coronary MRA: comparison of diaphragm and cardiac fat navigator techniques
    Thanh D Nguyen
    Pascal Spincemaille
    Martin R Prince
    Yi Wang
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [37] Free-breathing 3D cardiac extracellular volume (ECV) mapping using a linear tangent space alignment (LTSA) model
    Lee, Wonil
    Han, Paul Kyu
    Marin, Thibault
    Mounime, Ismael B. G.
    Eslahi, Samira Vafay
    Djebra, Yanis
    Chi, Didi
    Bijari, Felicitas J.
    Normandin, Marc D.
    El Fakhri, Georges
    Ma, Chao
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 536 - 549
  • [38] COMPARISON OF FREE-BREATHING 3D AND CONVENTIONAL 2D LATE GADOLINIUM ENHANCEMENT CARDIAC MR FOR THE EVALUATION OF LEFT VENTRICULAR INFARCTION
    Ma Ning
    Zhao Shihua
    Yin Gang
    Lu Minjie
    Jiang Shiliang
    Cheng Huaibing
    Liu Qiong
    Yang Xinling
    HEART, 2010, 96 : A217 - A217
  • [39] Application of single shot free-breathing fast imaging employing steady state sequence in cardiac magnetic resonance imaging
    Wang, Lidong
    Cheng, Liuquan
    Fang, Fang
    Han, Xiaodong
    Liu, Aishi
    Ma, Lin
    Gao, Peiyi
    Niu, Guangming
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2015, 35 (02) : 159 - 166
  • [40] Unsupervised free-breathing 3D imaging of morphology, function and flow in congenital heart disease
    Rajesh Krishnamurthy
    Ramkumar Krishnamurthy
    LaDonna Malone
    Elijah Bolin
    Amol Pednekar
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)